Ratiometric fluorescence probe constructed using metal-organic frameworks and nitrogen-doped carbon dots for specific detection of adenosine monophosphate

被引:7
|
作者
Zhang, Tian [1 ]
Tan, Qin [2 ]
Chen, Runchun [1 ]
Gan, Zhiwen [1 ]
Zhen, Shujun [1 ]
Hu, Xiaoli [1 ]
Peng, Huanjun [1 ]
机构
[1] Southwest Univ, Coll Chem & Chem Engn, Key Lab Luminescence Anal & Mol Sensing, Minist Educ, Chongqing 400715, Peoples R China
[2] SAic GM Wuling Automobile Co Ltd, Liuzhou 545007, Peoples R China
基金
中国国家自然科学基金;
关键词
Ratiometric fluorescence; Eu-MOF; Specific; AMP; LUMINESCENCE SENSORS; ELECTRODE;
D O I
10.1016/j.microc.2023.109171
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The selective detection of adenosine monophosphate (AMP) is of great significance for the study of cellular energy metabolism. In this study, a ratiometric fluorescent probe was designed based on europium-based met-al-organic frameworks (Eu-MOF) and nitrogen-doped carbon dots (CDs) that could specifically recognize AMP. Europium nitrate and Disodium Terephthalate (Na2BDC) were used to synthesize Eu-BDC with red fluorescence. The fluorescence of the Eu-BDC was effectively suppressed due to water molecules coordinating with the Eu3+. However, the addition of AMP resulted in a significant restoration of the fluorescence of Eu-BDC, while the fluorescence remained suppressed upon addition of adenosine diphosphate (ADP) and adenosine triphosphate (ATP). We developed a ratiometric fluorescence sensor that could accurately detect AMP by utilizing the blue fluorescence emitted from CDs as a reliable reference signal. Under optimal conditions, the Eu-BDC/CDs system for AMP detection exhibited a linear detection range of 1.0-80.0 & mu;mol/L and a low limit of detection (LOD) of 0.25 & mu;mol/L. The method displayed simple preparation, high selectivity and low cost for AMP detection. To our knowledge, this is the first highly-specify double-response biosensor for AMP.
引用
收藏
页数:7
相关论文
共 47 条
  • [41] Total Water Splitting Catalyzed by Co@Ir Core-Shell Nanoparticles Encapsulated in Nitrogen-Doped Porous Carbon Derived from Metal Organic Frameworks
    Li, Dongliang
    Zong, Zhuo
    Tang, Zhenghua
    Liu, Zhen
    Chen, Shaowei
    Tian, Yong
    Wang, Xiufang
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2018, 6 (04): : 5105 - 5114
  • [42] Eu3+-Doped Mixed-Ligand UiO-66-Type Metal-Organic Framework for Ratiometric Fluorescence Sensing Fluoride Ions with Ultralow Detection Limit
    Chen, Juan
    Guo, Tingting
    Gao, Hongyi
    He, Tao
    Li, Jie
    Li, Haijian
    Liu, Xinyu
    Li, Ang
    ACS APPLIED MATERIALS & INTERFACES, 2024, 16 (44) : 60278 - 60287
  • [43] Ratiometric fluorescence detection of tetracycline in milk and tap water with smartphone assistance for visual pH sensing using innovative dual-emissive phosphorus-doped carbon dots
    Kayani, Kawan F.
    Mohammed, Sewara J.
    Mohammad, Nian N.
    Abdullah, Gaylany H.
    Kader, Dana A.
    Mustafa, Namama S. Hamad
    FOOD CONTROL, 2024, 164
  • [44] 2D metal-organic framework derived ultra-thin nitrogen-doped oxygen rich porous carbon nanosheets for zinc-ion hybrid supercapacitors
    Han, Yu
    Zhang, Chiyu
    Chen, Kai-Jie
    Wang, Teng
    JOURNAL OF MATERIALS CHEMISTRY A, 2024, 12 (36) : 24296 - 24307
  • [45] Nitrogen-doped carbon dots coupled with morin-Al3+: Cleverly design an integrated sensing platform for ratiometric optical dual-mode and smartphone-assisted visual detection of fluoride ion
    Hao, Yumin
    Dong, Wenjuan
    Liu, Yang
    Wen, Xiaole
    Shuang, Shaomin
    Hu, Qin
    Dong, Chuan
    Gong, Xiaojuan
    JOURNAL OF HAZARDOUS MATERIALS, 2022, 439
  • [46] Metal-organic framework-derived cobalt nanoparticle space confined in nitrogen-doped carbon polyhedra networks as high-performance bifunctional electrocatalyst for rechargeable Li-O2 batteries
    Yu, Shun-zhi
    Luo, Shao-hua
    Zhan, Yang
    Huang, Hong-bo
    Wang, Qing
    Zhang, Ya-hui
    Liu, Yan-guo
    Hao, Aim-in
    JOURNAL OF POWER SOURCES, 2020, 453
  • [47] Ultrasensitive Ratiometric Fluorescence Bioassay for Accurate Detection of Covid-19-Specific Nucleocapsid Protein in Clinical Serum Samples Using Modified Cleavable Mesoporous SiO2 Satellite-Enriched Carbon Dots
    Hamd-Ghadareh, Somayeh
    Salimi, Abdollah
    Vaziry, Asaad
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2023, 9 (09) : 5279 - 5292