Experimental investigation of the performance of an air type photovoltaic thermal collector system with fixed cooling fins

被引:8
|
作者
Zhao, Zhonghua [1 ,4 ]
Zhu, Li [1 ,2 ]
Wang, Yiping [1 ,3 ]
Huang, Qunwu [3 ]
Sun, Yong [1 ,2 ]
机构
[1] Tianjin Univ, Sch Architecture, Tianjin 300072, Peoples R China
[2] Tianjin Univ, APEC Sustainable Energy Ctr, Tianjin 300072, Peoples R China
[3] Tianjin Univ, Sch Chem Engn & Technol, Tianjin 300072, Peoples R China
[4] Tianjin Renai Coll, Tianjin 301636, Peoples R China
关键词
Photovoltaic thermal (PV/T); Solar air collector; Thermal efficiency; Cooling fin; PV/T COLLECTOR; DESIGN;
D O I
10.1016/j.egyr.2023.02.059
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Solar energy may now be captured in two ways: heat extraction in solar collectors and electricity generation in photovoltaic panels. It may effectively reduce the degradation of PV cell efficiency caused by overheating of the battery by collecting the heat from the PV/T system. The heat dissipation cooling fin is directly mounted to the rear of the solar panel in this study and coated with an insulating layer to create an air-cooling channel. The heat dissipation fin transfers heat from the back of the photovoltaic panel to a certain mass flow of air in the flow channel, resulting in combined heat and power. The electrical and thermal capabilities of three distinct fin numbers were studied by monitoring electrical power and temperature data. A fixed mass flow rate (0.011 kg/s) for air, three different numbers of fins (0-5-10) and solar irradiance (200 W/m(2)-600 W/m(2)) are the experimental conditions. After the system was run stably for 10 min, the average temperature of the back of the PV panel, the device's inlet and outlet temperatures, and the PV panel's electric power were recorded. These figures are used to calculate the PV/T system's electrical and thermal efficiency. When the median electrical efficiency of the three types of fins is compared with varying solar irradiation, it is discovered that the electric efficiency value of the three types of fins is approximately 16%, with a difference of less than 0.6%. The comprehensive efficiency of five groups of fins and ten groups of fins was 61.08% and 69.85%, respectively, based on the median comparison of photoelectric photothermal comprehensive efficiency. The overall efficiency of the zero groups of fins was 26.27%, which was only 14.59% greater than the control plate, and there was a considerable difference between the five and ten groups of fins. This suggests that selecting the right number of fins has a substantial impact on improving PV/T thermal performance. This research will assist in further optimizing the design of PV/T systems for heat collection and will provide valuable information for PV/T system application in building integration. (c) 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under theCCBYlicense (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:93 / 100
页数:8
相关论文
共 50 条
  • [21] Experimental investigation of using the evaporative air cooling technique to enhance the performance of the photovoltaic module
    Jaffar, Malik F.
    Mohammad, Abdulrahman Th
    Ahmed, Ahmed Qasim
    Al-Shohani, Wisam A. M.
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2024, 19 : 1231 - 1245
  • [22] Experimental investigation of thermal performance of a heating system combining solar air collector with hollow ventilated interior wall
    Yu, Tao
    Zhao, Jiangdong
    Zhou, Jiri
    Lei, Bo
    RENEWABLE ENERGY, 2020, 147 : 1825 - 1835
  • [23] Theoretical and experimental research on effect of fins attachment on operating parameters and thermal efficiency of solar air collector
    Daliran A.
    Ajabshirchi Y.
    Information Processing in Agriculture, 2018, 5 (04): : 411 - 421
  • [24] Experimental analysis on thermal performance of a solar air collector with a single pass
    Yang, Ming
    Wang, Pengsu
    Yang, Xudong
    Shan, Ming
    BUILDING AND ENVIRONMENT, 2012, 56 : 361 - 369
  • [25] Comparison and evaluation of solar photovoltaic thermal system with hybrid collector: An experimental study
    Kazem, Hussein A.
    Chaichan, Miqdam T.
    Al-Waeli, Ali H. A.
    Sopian, K.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 22
  • [26] Experimental Studies on the Thermal Efficiency of the Single-Pass Solar Air Collector with Fins
    Ibrahim, Zamry
    Ibarahim, Zahari
    Yatim, Baharudin
    Ruslan, Mohd Hafidz
    2012 NATIONAL PHYSICS CONFERENCE (PERFIK 2012), 2013, 1528 : 118 - 122
  • [27] Experimental Investigation of Thermal Efficiency of Solar Air Collector with Trapeze Absorber Plate
    Abuska, Mesut
    Akgul, Mehmet Bahattin
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2014, 17 (04): : 177 - 181
  • [28] Experimental investigation of jet array nanofluids impingement in photovoltaic/thermal collector
    Hasan, Husam Abdulrasool
    Sopian, Kamaruzzaman
    Jaaz, Ahed Hameed
    Al-Shamani, Ali Najah
    SOLAR ENERGY, 2017, 144 : 321 - 334
  • [29] Insight into the Investigation of Thermo-Electrical Performance of Hybrid Photovoltaic-Thermal Air-Collector
    Diwania S.
    Kumar M.
    Gupta V.
    Agrawal S.
    Khetrapal P.
    Gupta N.
    Journal of The Institution of Engineers (India): Series B, 2024, 105 (05) : 1275 - 1283
  • [30] Research on the Performance of Flat-Box Photovoltaic/Thermal Collector With Cooling Channels
    Zhang Heng
    Liu Haowen
    Chen Haiping
    Guo Xinxin
    Liang Kai
    Yao Pengbo
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (02):