An electrochemical sensor based on CS-MWCNT and AuNPs for the detection of mycophenolic acid in plasma

被引:2
|
作者
Xiong, Yan [1 ]
Zhu, Shu [2 ]
Zhao, Hua [1 ]
Li, Jin [1 ,3 ]
Li, Yanting [1 ]
Gong, Tao [4 ]
Tao, Yanru [1 ]
Hu, Jiangling [1 ]
Wang, Hongmei [1 ,5 ]
Jiang, Xinhui [1 ,6 ]
机构
[1] Chongqing Med Univ, Chongqing Res Ctr Pharmaceut Engn, Sch Pharm, Chongqing 400016, Peoples R China
[2] Chongqing Med Univ, Lab Teaching & Management Ctr, Lab Pharm & Chem, Chongqing 400016, Peoples R China
[3] Chongqing Med Univ, Childrens Hosp Affiliated, Dept Pharm, Chongqing 400014, Peoples R China
[4] Nanchong Cent Hosp, Nanchong Key Lab Individualized Drug Therapy, Nanchong 637000, Sichuan, Peoples R China
[5] Chongqing Lybon Pharm Tech Co Ltd, Fu Pharmaceut Grp, Chongqing 401121, Peoples R China
[6] Chongqing Med Univ, Chongqing Res Ctr Pharmaceut Engn, Sch Pharm, 1 Yixueyuan Rd, Chongqing 400016, Peoples R China
关键词
Mycophenolic acid; Cyclic voltammetry; Green electrochemical sensor; CS-MWCNT; AuNPs; GCE; High performance liquid phase; REDUCED GRAPHENE OXIDE; GOLD NANOPARTICLES; CARBON NANOTUBES; SENSITIVE DETERMINATION; MECHANICAL-PROPERTIES; IONIC LIQUID; CHITOSAN; ELECTRODE; MOFETIL; IMMUNOSENSOR;
D O I
10.1016/j.ab.2023.115265
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For patients receiving organ transplants, monitoring the blood concentration of MPA can provide timely information on whether MPA has reached the effective therapeutic window to better function while reducing the incidence of rejection or adverse reactions. In this study, an electrochemical sensor for the detection of MPA was built using a nanocomposite made of CS-MWCNT and AuNPs. At the same time, the high performance liquid phase (HPLC) method for MPA was established and compared with this sensor. The surface morphology, structure, and roughness of the material on the electrode were characterized by scanning electron microscopy (SEM), Fourier transforms infrared spectroscopy (FTIR), and atomic force microscopy (AFM). In addition, the electrochemical behavior of the modified electrode was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The standard curve was obtained in blank plasma, not pure buffer solution. The peak current was linearly related to the MPA concentration in the linear range of 0.001-0.1 mM with a detection limit of 0.05 & mu;M and good anti-interference ability. Moreover, the sensor was employed with success for the determination of MPA in rat plasma with good recovery. The electrochemical sensor presented here is eco-friendly, and sensitive, and offers a great possibility for practical applicability.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Electrochemical sensor based on covalent organic frameworks-MWCNT-NH2/AuNPs for simultaneous detection of dopamine and uric acid
    Guan, Qixia
    Guo, Hao
    Xue, Rui
    Wang, Mingyue
    Zhao, Xin
    Fan, Tian
    Yang, Wenhu
    Xu, Mengni
    Yang, Wu
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 880
  • [2] A novel electrochemical sensor for uric acid detection based on PCN/MWCNT
    Lv, Jingjing
    Li, Caiwei
    Feng, Shasha
    Chen, Shen-Ming
    Ding, Yong
    Chen, Chenglong
    Hao, Qingli
    Yang, Ting-Hai
    Lei, Wu
    IONICS, 2019, 25 (09) : 4437 - 4445
  • [3] A novel electrochemical sensor for uric acid detection based on PCN/MWCNT
    Jingjing Lv
    Caiwei Li
    Shasha Feng
    Shen-Ming Chen
    Yong Ding
    Chenglong Chen
    Qingli Hao
    Ting-Hai Yang
    Wu Lei
    Ionics, 2019, 25 : 4437 - 4445
  • [4] CuS–MWCNT based electrochemical sensor for sensitive detection of bisphenol A
    X. C. Lu
    L. Song
    T. T. Ding
    Y. L. Lin
    C. X. Xu
    Russian Journal of Electrochemistry, 2017, 53 : 366 - 373
  • [5] An electrochemical sensor based on CNF@AuNPs for metronidazole hypersensitivity detection
    Zhang, Li
    Yin, Ming
    Qiu, Jingxuan
    Qiu, Tianyi
    Chen, Yan
    Qi, Shuyan
    Wei, Xiuxia
    Tian, Xinxin
    Xu, Dongpo
    Biosensors and Bioelectronics: X, 2022, 10
  • [6] Electrochemical Sensor based on Polyethyleneimine-AuNPs-Anthraquinone-2-carboxylic acid Nanocomposite for Cysteine Detection
    Li, Manman
    Guo, Zhuangzhuang
    Yang, Huaixia
    Liu, Yanju
    Tong, Yan
    Kong, Jinming
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (01): : 943 - 956
  • [7] CuS-MWCNT Based Electrochemical Sensor for Sensitive Detection of Bisphenol A
    Lu, X. C.
    Song, L.
    Ding, T. T.
    Lin, Y. L.
    Xu, C. X.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2017, 53 (04) : 366 - 373
  • [8] Electrochemical Sensor for Detection of Ascorbic Acid based on MoS2-AuNPs Modified Glassy Carbon Electrode
    Huang, Mengting
    Tian, Huimin
    Zhou, Peilan
    Ma, Shangshang
    Chen, Jingmin
    Zhang, Na
    Zhang, Keying
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (01): : 1 - 8
  • [9] Electrochemical immunosensor based on MWCNT-CS as a signal amplification strategy for the detection of capsaicinoids
    Yang, Fengzhen
    Yang, Qingqing
    Li, Jiansen
    Kong, Qianqian
    Huang, Jingcheng
    Xu, Rui
    Xiang, Yaodong
    Guo, Yemin
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (11): : 1 - 10
  • [10] CD/AuNPs/MWCNTs based electrochemical sensor for quercetin dual-signal detection
    Kan, Xianwen
    Zhang, Tingting
    Zhong, Min
    Lu, Xiaojing
    BIOSENSORS & BIOELECTRONICS, 2016, 77 : 638 - 643