Hemodynamic study of blood flow in the aorta during the interventional robot treatment using fluid-structure interaction

被引:1
|
作者
Zhu, Zongming [1 ]
Ji, Suqiang [2 ]
Liang, Liang [1 ]
Wang, Hao [3 ]
Xia, Haoyu [4 ]
Tang, Puhua [1 ]
机构
[1] Changsha Univ, Coll Electromech Engn, Changsha 410022, Peoples R China
[2] Xiangtan Univ, Sch Mech Engn & Mech, Xiangtan 411105, Peoples R China
[3] Hunan Normal Univ, Coll Engn & Design, Changsha 410081, Peoples R China
[4] Changsha Inst Min Res Co LTD, Changsha 410012, Peoples R China
基金
中国国家自然科学基金;
关键词
Vascular interventional robot; Fluid-structure interaction (FSI); Hemodynamics; Computational fluid dynamics (CFD); Particle image velocimetry (PIV); DISSECTION; STENTS;
D O I
10.1007/s10237-023-01737-y
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An interventional robot is a means for vascular diagnosis and treatment, and it can perform dredging, releasing drug and operating. Normal hemodynamic indicators are a prerequisite for the application of interventional robots. The current hemodynamic research is limited to the absence of interventional devices or interventional devices in fixed positions. Considering the coupling effect of blood, vessels and robots, based on the bi-directional fluid-structure interaction, using the computational fluid dynamics and particle image velocimetry methods, combined with the sliding and moving mesh technologies, we theoretically and experimentally study the hemodynamic indicators such as blood flow lines, blood pressure, equivalent stress, deformation and wall shear stress of blood vessels when the robot precesses, rotates or does not intervene in the pulsating blood flow. The results show that the intervention of the robot increase the blood flow rate, blood pressure, equivalent stress and deformation of the vessels by 76.4%, 55.4%, 76.5%, and 346%, respectively. The operating mode of the robot during low-speed operation has little impact on the hemodynamic indicators. Using the methyl silicone oil as the experimental fluid, the elastic silicone pipe as the experimental pipe, and the intervention robot having a bioplastic outer shell, the velocity of the fluid around the robot is measured on the developed experimental device for fluid flow field in a pulsating flow when the robot runs. The experimental results are similar to the numerical results. Our work provides an important reference for the hemodynamic study and optimization of the mobile interventional devices.
引用
收藏
页码:1857 / 1872
页数:16
相关论文
共 50 条
  • [41] Effect of TAVR commissural alignment on coronary flow: A fluid-structure interaction analysis
    Oks, David
    Houzeaux, Guillaume
    Vazquez, Mariano
    Neidlin, Michael
    Samaniego, Cristobal
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 242
  • [42] Fluid-Structure Interaction Study of Transcatheter Aortic Valve Dynamics Using Smoothed Particle Hydrodynamics
    Mao, Wenbin
    Li, Kewei
    Sun, Wei
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2016, 7 (04) : 374 - 388
  • [43] A Fluid-Structure Interaction case study on a square sail in a wind tunnel
    Ghelardi, Stefano
    Freda, Andrea
    Rizzo, Cesare Mario
    Villa, Diego
    OCEAN ENGINEERING, 2018, 163 : 136 - 147
  • [44] Analysis of finite element and finite volume methods for fluid-structure interaction simulation of blood flow in a real stenosed artery
    Lopes, D.
    Agujetas, R.
    Puga, H.
    Teixeira, J.
    Lima, R.
    Alejo, J. P.
    Ferrera, C.
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2021, 207
  • [45] Numerical simulation of two-phase non-Newtonian blood flow with fluid-structure interaction in aortic dissection
    Qiao, Yonghui
    Zeng, Yujie
    Ding, Ying
    Fan, Jianren
    Luo, Kun
    Zhu, Ting
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (06) : 620 - 630
  • [46] MODELING OF AERODYNAMIC DECELERATOR INFLATION USING FLUID-STRUCTURE INTERACTION STRATEGIES
    Malof, Emanuel
    Bayandor, Javid
    PROCEEDINGS OF ASME 2024 FLUIDS ENGINEERING DIVISION SUMMER MEETING, VOL 2, FEDSM 2024, 2024,
  • [47] Modeling of aortic valve stenosis using fluid-structure interaction method
    Ghasemi Pour, Mohammad Javad
    Hassani, Kamran
    Khayat, Morteza
    Etemadi Haghighi, Shahram
    PERFUSION-UK, 2022, 37 (04): : 367 - 376
  • [48] AnXplore: a comprehensive fluid-structure interaction study of 101 intracranial aneurysms
    Goetz, Aurele
    Jeken-Rico, Pablo
    Pelissier, Ugo
    Chau, Yves
    Sedat, Jacques
    Hachem, Elie
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [49] Structure Integrity Analysis Using Fluid-Structure Interaction at Hydropower Bottom Outlet Discharge
    Radzi, Mohd Rashid Mohd
    Zawawi, Mohd Hafiz
    Abas, Mohamad Aizat
    Mazlan, Ahmad Zhafran Ahmad
    Zainol, Mohd Remy Rozainy Mohd Arif
    Hassan, Nurul Husna
    Zanial, Wan Norsyuhada Che Wan
    Dullah, Hayana
    Kamaruddin, Mohamad Anuar
    WATER, 2023, 15 (06)
  • [50] Fluid-structure interaction simulation of pulse propagation in arteries: Numerical pitfalls and hemodynamic impact of a local stiffening
    Taelman, L.
    Degroote, J.
    Swillens, A.
    Vierendeels, J.
    Segers, P.
    INTERNATIONAL JOURNAL OF ENGINEERING SCIENCE, 2014, 77 : 1 - 13