Hemodynamic study of blood flow in the aorta during the interventional robot treatment using fluid-structure interaction

被引:1
|
作者
Zhu, Zongming [1 ]
Ji, Suqiang [2 ]
Liang, Liang [1 ]
Wang, Hao [3 ]
Xia, Haoyu [4 ]
Tang, Puhua [1 ]
机构
[1] Changsha Univ, Coll Electromech Engn, Changsha 410022, Peoples R China
[2] Xiangtan Univ, Sch Mech Engn & Mech, Xiangtan 411105, Peoples R China
[3] Hunan Normal Univ, Coll Engn & Design, Changsha 410081, Peoples R China
[4] Changsha Inst Min Res Co LTD, Changsha 410012, Peoples R China
基金
中国国家自然科学基金;
关键词
Vascular interventional robot; Fluid-structure interaction (FSI); Hemodynamics; Computational fluid dynamics (CFD); Particle image velocimetry (PIV); DISSECTION; STENTS;
D O I
10.1007/s10237-023-01737-y
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An interventional robot is a means for vascular diagnosis and treatment, and it can perform dredging, releasing drug and operating. Normal hemodynamic indicators are a prerequisite for the application of interventional robots. The current hemodynamic research is limited to the absence of interventional devices or interventional devices in fixed positions. Considering the coupling effect of blood, vessels and robots, based on the bi-directional fluid-structure interaction, using the computational fluid dynamics and particle image velocimetry methods, combined with the sliding and moving mesh technologies, we theoretically and experimentally study the hemodynamic indicators such as blood flow lines, blood pressure, equivalent stress, deformation and wall shear stress of blood vessels when the robot precesses, rotates or does not intervene in the pulsating blood flow. The results show that the intervention of the robot increase the blood flow rate, blood pressure, equivalent stress and deformation of the vessels by 76.4%, 55.4%, 76.5%, and 346%, respectively. The operating mode of the robot during low-speed operation has little impact on the hemodynamic indicators. Using the methyl silicone oil as the experimental fluid, the elastic silicone pipe as the experimental pipe, and the intervention robot having a bioplastic outer shell, the velocity of the fluid around the robot is measured on the developed experimental device for fluid flow field in a pulsating flow when the robot runs. The experimental results are similar to the numerical results. Our work provides an important reference for the hemodynamic study and optimization of the mobile interventional devices.
引用
收藏
页码:1857 / 1872
页数:16
相关论文
共 50 条
  • [21] A simplified method to account for wall motion in patient-specific blood flow simulations of aortic dissection: Comparison with fluid-structure interaction
    Bonfanti, Mirko
    Balabani, Stavroula
    Alimohammadi, Mona
    Agu, Obiekezie
    Homer-Vanniasinkam, Shervanthi
    Diaz-Zuccarini, Vanessa
    MEDICAL ENGINEERING & PHYSICS, 2018, 58 : 72 - 79
  • [22] Numerical analysis of the hemodynamics of rat aorta based on magnetic resonance imaging and fluid-structure interaction
    Han, Longzhu
    Ren, Quan
    Lian, Jianxiu
    Luo, Liyi
    Liu, Huawei
    Ma, Tianxiang
    Li, Xin
    Deng, Xiaoyan
    Liu, Xiao
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2021, 37 (06)
  • [23] Spatiotemporal analysis of the effects of exercise on the hemodynamics of the aorta in hypertensive rats using fluid-structure interaction simulation
    Wang, Yueshen
    Yu, Haiyi
    Shi, Quanyou
    Xu, Ming
    Gao, Wei
    JOURNAL OF TRANSLATIONAL INTERNAL MEDICINE, 2024, 12 (01) : 64 - 77
  • [24] Fluid-Structure Interaction Simulation of Blood Flow and Cerebral Aneurysm: Effect of Partly Blocked Vessel
    Saeedi, Milad
    Shamloo, Amir
    Mohammadi, Ariz
    JOURNAL OF VASCULAR RESEARCH, 2019, 56 (06) : 296 - 307
  • [25] WING FLUTTER ANALYSIS USING COMPUTATIONAL FLUID-STRUCTURE INTERACTION DYNAMICS
    Pohly, Jeremy A.
    Zhang, Mike R.
    Zhang, Sijun
    PROCEEDINGS OF ASME 2021 FLUIDS ENGINEERING DIVISION SUMMER MEETING (FEDSM2021), VOL 1, 2021,
  • [26] Fluid-structure interaction modeling of blood flow and cerebral aneurysm: Significance of artery and aneurysm shapes
    Torii, Ryo
    Oshima, Marie
    Kobayashi, Toshio
    Takagi, Kiyoshi
    Tezduyar, Tayfun E.
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2009, 198 (45-46) : 3613 - 3621
  • [27] Study on the Fluid-Structure Interaction of Flexible Printed Circuit Board Electronics in the Flow Environment
    Leong, Wei Chiat
    Abdullah, Mohd Zulkifly
    Khor, Chu Yee
    Ong, Ernest Ern Seang
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2012, 2 (08): : 1335 - 1345
  • [28] Modeling blood flow in viscoelastic vessels: the 1D augmented fluid-structure interaction system
    Bertaglia, Giulia
    Caleffi, Valerio
    Valiani, Alessandro
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2020, 360
  • [29] A 3D non-Newtonian fluid-structure interaction model for blood flow in arteries
    Janela, Joao
    Moura, Alexandra
    Sequeira, Adelia
    JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 2010, 234 (09) : 2783 - 2791
  • [30] Effect of aortic bifurcation geometry on pressure and peak wall stress in abdominal aorta: Fluid-structure interaction study
    Jagos, Jiri
    Schwarz, David
    Polzer, Stanislav
    Bursa, Jiri
    MEDICAL ENGINEERING & PHYSICS, 2023, 118