Enantiomeric Separation and Degradation of Benoxacor Enantiomers in Horticultural Soil by Normal-Phase and Reversed-Phase High Performance Liquid Chromatography

被引:2
|
作者
Zhu, Haoxiang [1 ]
Qin, Kunrong [1 ]
Zhang, Ping [2 ]
Wang, Haiyang [1 ]
机构
[1] Southwest Univ, Coll Hort & Landscape Architecture, Chongqing 400715, Peoples R China
[2] Southwest Univ, Coll Plant Protect, Chongqing 400715, Peoples R China
关键词
benoxacor; chiral separation; enantiomers; enantioselectivity; soil degradation; CHIRAL STATIONARY PHASES; PESTICIDES; ENANTIOSELECTIVITY; STEREOISOMERS; RESOLUTION;
D O I
10.3390/ijms24108887
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The separation of benoxacor enantiomers on six commercial chiral columns was investigated by high-performance liquid chromatography (HPLC) under normal-phase and reversed-phase conditions. The mobile phases included hexane/ethanol, hexane/isopropanol, acetonitrile/water, and methanol/water. The effects of the chiral stationary phases (CSPs), temperature, and mobile phase composition and ratio on the separation of benoxacor enantiomers were examined. Under normal-phase conditions, the two benoxacor enantiomers were completely separated on Chiralpak AD, Chiralpak IC, Lux Cellulose-1, and Lux Cellulose-3 columns and partially separated on a Lux Cellulose-2 column. Under reversed-phase conditions, benoxacor enantiomers were completely separated on a Lux Cellulose-3 column and partially separated on Chiralpak IC and Lux Cellulose-1 columns. Normal-phase HPLC performed better than reversed-phase HPLC for the separation of benoxacor enantiomers. As the column temperature increased from 10 degrees C to 4 degrees C, the enthalpy (Delta H) and entropy (Delta S) results indicated that the resolution was strongly affected by the temperature and that the lowest temperature did not always produce the best resolution. An optimized separation method on the Lux Cellulose-3 column was used to investigate the stability of benoxacor enantiomers in solvents and the degradation of benoxacor enantiomers in three types of horticultural soil. Benoxacor enantiomers were stable, and degradation or racemization were not observed in methanol, ethanol, isopropanol, acetonitrile, hexane, or water (pH = 4.0, 7.0, and 9.0). In three horticultural soils, the degradation rate of S-benoxacor was faster than that of R-benoxacor, resulting in soil enrichment with R-benoxacor. The results of this study will help to improve the risk assessment of enantiomer levels of benoxacor in the environment.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Reversed-phase chiral high-performance liquid chromatography method for separation of abacavir sulfate enantiomer in drug substance
    Ramesh, Ch.
    Rama Devi, Dharmasoth
    Srinivas, MNB.
    Rajana, Nagaraju
    Krishna, S. Radha
    Basavaiah, K.
    SEPARATION SCIENCE PLUS, 2020, 3 (11-12): : 553 - 560
  • [32] Chiral separation of five arylpropionic acid drugs and determination of their enantiomers in pharmaceutical preparations by reversed-phase high performance liquid chromatography with cellulose-tris- (4-methylbenzoate) stationary phase
    Luo An
    Wan Qiang
    Fan Huajun
    Chen Zhi
    Wu Xuehao
    Huang Xiaowen
    Zang Linquan
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (09) : 1013 - 1018
  • [33] Chiral separations in reversed-phase liquid chromatography: Evaluation of several polysaccharide-based chiral stationary phases for a separation strategy update
    Younes, Ahmed A.
    Mangelings, Debby
    Vander Heyden, Yvan
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1269 : 154 - 167
  • [34] Enantiomeric separation of naproxen by high performance liquid chromatography using CHIRALCEL OD as stationary phase
    Chen De-Miao
    Qiang, Fu
    Na, Li
    Zhang Song-Xian
    Zhang Qian-Qian
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (01) : 75 - 78
  • [35] Comparative Study of Ion Interaction Reagents for the Separation of Lanthanides by Reversed-Phase High Performance Liquid Chromatography (RP-HPLC)
    Jaison, P. G.
    Kumar, Pranaw
    Telmore, Vijay M.
    Aggarwal, Suresh K.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2009, 32 (15) : 2146 - 2163
  • [36] Reversed-Phase-Reversed-Phase Liquid Chromatography Approach with High Orthogonality for Multidimensional Separation of Phosphopeptides
    Song, Chunxia
    Ye, Mingliang
    Han, Guanghui
    Jiang, Xinning
    Wang, Fangjun
    Yu, Zhiyuan
    Chen, Rui
    Zou, Hanfa
    ANALYTICAL CHEMISTRY, 2010, 82 (01) : 53 - 56
  • [37] Elucidation of retention behaviors in reversed-phase liquid chromatography as a function of mobile phase composition
    Tsui, Hung-Wei
    Kuo, Che-Hung
    Huang, Yung-Chen
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1595 : 127 - 135
  • [38] Resolution of salbutamol enantiomers in human urine by reversed-phase high performance liquid chromatography after derivatization with (S)-(-)-alpha-methylbenzyl isocyanate
    Kim, KH
    Kim, TK
    Kwon, YH
    Sohn, YT
    ARCHIVES OF PHARMACAL RESEARCH, 1997, 20 (05) : 486 - 490
  • [39] Molecular simulation studies of reversed-phase liquid chromatography
    Lindsey, Rebecca K.
    Rafferty, Jake L.
    Eggimann, Becky L.
    Siepmann, J. Ilja
    Schure, Mark R.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1287 : 60 - 82
  • [40] Computerized design of separation strategies by reversed-phase liquid chromatography: development of DryLab software
    Molnar, I
    JOURNAL OF CHROMATOGRAPHY A, 2002, 965 (1-2) : 175 - 194