Enantiomeric Separation and Degradation of Benoxacor Enantiomers in Horticultural Soil by Normal-Phase and Reversed-Phase High Performance Liquid Chromatography

被引:2
|
作者
Zhu, Haoxiang [1 ]
Qin, Kunrong [1 ]
Zhang, Ping [2 ]
Wang, Haiyang [1 ]
机构
[1] Southwest Univ, Coll Hort & Landscape Architecture, Chongqing 400715, Peoples R China
[2] Southwest Univ, Coll Plant Protect, Chongqing 400715, Peoples R China
关键词
benoxacor; chiral separation; enantiomers; enantioselectivity; soil degradation; CHIRAL STATIONARY PHASES; PESTICIDES; ENANTIOSELECTIVITY; STEREOISOMERS; RESOLUTION;
D O I
10.3390/ijms24108887
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The separation of benoxacor enantiomers on six commercial chiral columns was investigated by high-performance liquid chromatography (HPLC) under normal-phase and reversed-phase conditions. The mobile phases included hexane/ethanol, hexane/isopropanol, acetonitrile/water, and methanol/water. The effects of the chiral stationary phases (CSPs), temperature, and mobile phase composition and ratio on the separation of benoxacor enantiomers were examined. Under normal-phase conditions, the two benoxacor enantiomers were completely separated on Chiralpak AD, Chiralpak IC, Lux Cellulose-1, and Lux Cellulose-3 columns and partially separated on a Lux Cellulose-2 column. Under reversed-phase conditions, benoxacor enantiomers were completely separated on a Lux Cellulose-3 column and partially separated on Chiralpak IC and Lux Cellulose-1 columns. Normal-phase HPLC performed better than reversed-phase HPLC for the separation of benoxacor enantiomers. As the column temperature increased from 10 degrees C to 4 degrees C, the enthalpy (Delta H) and entropy (Delta S) results indicated that the resolution was strongly affected by the temperature and that the lowest temperature did not always produce the best resolution. An optimized separation method on the Lux Cellulose-3 column was used to investigate the stability of benoxacor enantiomers in solvents and the degradation of benoxacor enantiomers in three types of horticultural soil. Benoxacor enantiomers were stable, and degradation or racemization were not observed in methanol, ethanol, isopropanol, acetonitrile, hexane, or water (pH = 4.0, 7.0, and 9.0). In three horticultural soils, the degradation rate of S-benoxacor was faster than that of R-benoxacor, resulting in soil enrichment with R-benoxacor. The results of this study will help to improve the risk assessment of enantiomer levels of benoxacor in the environment.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Chiral Separation and Determination of Etoxazole Enantiomers in Vegetables by Normal-Phase and Reverse-Phase High Performance Liquid Chromatography
    Zhang, Ping
    He, Yuhan
    Wang, Sheng
    Shi, Dongmei
    Xu, Yangyang
    Yang, Furong
    Wang, Jianhao
    He, Lin
    MOLECULES, 2020, 25 (14):
  • [2] Separation of chiral primary amino compounds by forming a sandwiched complex in reversed-phase high performance liquid chromatography
    Zhang, Chen
    Huang, Wei X.
    Chen, Zhi
    Rustum, Abu M.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (30) : 4965 - 4970
  • [3] Direct Enantiomeric Separation and Determination of Hexythiazox Enantiomers in Environment and Vegetable by Reverse-Phase High-Performance Liquid Chromatography
    Zhang, Ping
    Wang, Sheng
    Shi, Dongmei
    Xu, Yangyang
    Yang, Furong
    Deng, Xile
    He, Yuhan
    He, Lin
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (10)
  • [4] Engineering thiol-ene click chemistry for the preparation of a chiral stationary phase based on a [4+6]-type homochiral porous organic cage for enantiomeric separation in normal-phase and reversed-phase high performance liquid chromatography
    Liang, Rui-Xue
    Zhang, You-Ping
    Zhang, Jun-Hui
    Gong, Ya-Nan
    Huang, Bin
    Wang, Bang-Jin
    Xie, Sheng-Ming
    Yuan, Li-Ming
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1711
  • [5] "Click" preparation of a chiral macrocycle-based stationary phase for both normal-phase and reversed-phase high performance liquid chromatography enantioseparation
    Zhang, You -Ping
    Li, Kuan
    Xiong, Ling-Xiao
    Wang, Bang-Jin
    Xie, Sheng-Ming
    Zhang, Jun -Hui
    Yuan, Li -Ming
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1683
  • [6] Simultaneous determination of paclobutrazol and myclobutanil enantiomers in water and soil using enantioselective reversed-phase liquid chromatography
    Tian, Qin
    Zhou, Zhiqiang
    Lv, Chunguang
    Huang, Yi
    Ren, Liping
    ANALYTICAL METHODS, 2010, 2 (06) : 617 - 622
  • [7] Enantiomeric Separation of Chiral Pesticides by Permethylated β-Cyclodextrin Stationary Phase in Reversed Phase Liquid Chromatography
    Yan, Jin
    Zhang, Renke
    Wang, Xinru
    Wang, Yao
    Wang, Dezhen
    Zhou, Zhiqiang
    Zhu, Wentao
    CHIRALITY, 2016, 28 (05) : 409 - 414
  • [8] Separation of enantiomers on bovine serum albumin coated zirconia in reversed-phase liquid chromatography
    J. H. Park
    J. K. Ryu
    J. K. Park
    C. V. McNeff
    P. W. Carr
    Chromatographia, 2001, 53 : 405 - 408
  • [9] Separation of enantiomers on bovine serum albumin coated zirconia in reversed-phase liquid chromatography
    Park, JH
    Ryu, JK
    Park, JK
    McNeff, CV
    Carr, PW
    CHROMATOGRAPHIA, 2001, 53 (7-8) : 405 - 408
  • [10] Direct resolution of ibuprofen enantiomers by reversed-phase high performance liquid chromatography with amide derivative as chiral stationary phase
    Zhang, YH
    Yun, ZH
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (03) : 309 - 311