Experimental Demonstration of Compact Polymer Mass Transfer Device Manufactured by Additive Manufacturing with Hydrogel Integration to Bio-Mimic the Liver Functions

被引:2
作者
Narendran, Ganesan [1 ]
Walunj, Avdhoot [2 ]
Kumar, A. Mohan [3 ]
Jeyachandran, Praveen [4 ]
Awwad, Nasser S. S. [5 ]
Ibrahium, Hala A. A. [6 ]
Gorji, M. R. [7 ]
Perumal, D. Arumuga [1 ]
机构
[1] Natl Inst Technol Karnataka, Dept Mech Engn, Micro & Nanofluid Lab, Mangaluru 575025, India
[2] Dept Mech Engn, Mahatma Phule Krishi Vidyapeeth, Rahuri 413722, Maharashtra, India
[3] All India Inst Med Sci, Dept Clin Microbiol, Mangalagiri 522503, Andhra Pradesh, India
[4] Natl Inst Technol Karnataka, Dept Mech Engn, Mangaluru 575025, India
[5] King Khalid Univ, Coll Sci, Dept Chem, POB 9004, Abha 61413, Saudi Arabia
[6] King Khalid Univ, Coll Sci, Dept Biol, POB 9004, Abha 61413, Saudi Arabia
[7] Univ Ghent, Fac Med & Hlth Sci, B-9000 Ghent, Belgium
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 04期
关键词
liver function; biomimicry; additive manufacturing; hydrogel; selective laser sintering;
D O I
10.3390/bioengineering10040416
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In this paper, we designed and demonstrated a stimuli-responsive hydrogel that mimics the mass diffusion function of the liver. We have controlled the release mechanism using temperature and pH variations. Additive manufacturing technology was used to fabricate the device with nylon (PA-12), using selective laser sintering (SLS). The device has two compartment sections: the lower section handles the thermal management, and feeds temperature-regulated water into the mass transfer section of the upper compartment. The upper chamber has a two-layered serpentine concentric tube; the inner tube carries the temperature-regulated water to the hydrogel using the given pores. Here, the hydrogel is present in order to facilitate the release of the loaded methylene blue (MB) into the fluid. By adjusting the fluid's pH, flow rate, and temperature, the deswelling properties of the hydrogel were examined. The weight of the hydrogel was maximum at 10 mL/min and decreased by 25.29% to 10.12 g for the flow rate of 50 mL/min. The cumulative MB release at 30 degrees C increased to 47% for the lower flow rate of 10 mL/min, and the cumulative release at 40 degrees C climbed to 55%, which is 44.7% more than at 30 degrees C. The MB release rates considerably increased when the pH dropped from 12 to 8, showing that the lower pH had a major impact on the release of MB from the hydrogel. Only 19% of the MB was released at pH 12 after 50 min, and after that, the release rate remained nearly constant. At higher fluid temperatures, the hydrogels lost approximately 80% of their water in just 20 min, compared to a loss of 50% of their water at room temperature. The outcomes of this study may contribute to further developments in artificial organ design.
引用
收藏
页数:19
相关论文
共 55 条
  • [21] Extracorporeal Removal of Poisons and Toxins
    King, Joshua David
    Kern, Moritz H.
    Jaar, Bernard G.
    [J]. CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2019, 14 (09): : 1408 - 1415
  • [22] Increased Cell-Free DNA Plasma Concentration Following Liver Transplantation Is Linked to Portal Hepatitis and Inferior Survival
    Krenzien, Felix
    Katou, Shadi
    Papa, Alba
    Sinn, Bruno
    Benzing, Christian
    Feldbruegge, Linda
    Kamali, Can
    Brunnbauer, Philipp
    Splith, Katrin
    Lorenz, Ralf Roland
    Ritschl, Paul
    Wiering, Leke
    Oelinger, Robert
    Schoening, Wenzel
    Pratschke, Johann
    Schmelzle, Moritz
    [J]. JOURNAL OF CLINICAL MEDICINE, 2020, 9 (05)
  • [23] Gastrointestinal and liver manifestations in patients with COVID-19
    Lee, I-Cheng
    Huo, Teh-Ia
    Huang, Yi-Hsiang
    [J]. JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2020, 83 (06) : 521 - 523
  • [24] Molecular bases for temperature sensitivity in supramolecular assemblies and their applications as thermoresponsive soft materials
    Liu, Hongxu
    Prachyathipsakul, Theeraphop
    Koyasseril-Yehiya, Thameez M.
    Le, Stephanie P.
    Thayumanavan, S.
    [J]. MATERIALS HORIZONS, 2022, 9 (01) : 164 - 193
  • [25] Under pressure: Hydrogel swelling in a granular medium
    Louf, Jean-Francois
    Lu, Nancy B.
    O'Connell, Margaret G.
    Cho, H. Jeremy
    Datta, Sujit S.
    [J]. SCIENCE ADVANCES, 2021, 7 (07):
  • [26] Poly(acrylamide) hydrogel composites with microsized β-chitin fiber and the properties of mechanical and drug release
    Lv, Jianhua
    Fang, Yaru
    Wu, Mi
    Ou, Xiaoyu
    Zhang, Wenchang
    Wang, Shiyu
    Li, Huaiguo
    Shang, Lei
    He, Mingfeng
    Zhao, Yan
    [J]. MATERIALS TODAY COMMUNICATIONS, 2023, 34
  • [27] Management of decompensated cirrhosis
    Mansour, Dina
    McPherson, Stuart
    [J]. CLINICAL MEDICINE, 2018, 18 (02) : S60 - S65
  • [28] Artificial liver support systems: what is new over the last decade?
    Martinez, Juan Jose Garcia
    Bendjelid, Karim
    [J]. ANNALS OF INTENSIVE CARE, 2018, 8
  • [29] Functional anatomy and blood supply of the liver
    Mitra, Vikramjit
    Metcalf, Jane
    [J]. ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2009, 10 (07) : 332 - 335
  • [30] Artificial intelligence in liver diseases: Improving diagnostics, prognostics and response prediction
    Nam, David
    Chapiro, Julius
    Paradis, Valerie
    Seraphin, Tobias Paul
    Kather, Jakob Nikolas
    [J]. JHEP REPORTS, 2022, 4 (04)