Acute effects of conventional versus wide-pulse neuromuscular electrical stimulation on quadriceps evoked torque and neuromuscular function

被引:1
|
作者
Espeit, Loic [1 ]
Luneau, Eric [1 ]
Brownstein, Callum G. [1 ]
Gondin, Julien [2 ]
Millet, Guillaume Y. [1 ,3 ]
Rozand, Vianney [1 ]
Maffiuletti, Nicola A. [4 ]
Lapole, Thomas [1 ,5 ]
机构
[1] Univ Savoie Mont Blanc, Univ Jean Monnet St Etienne, Lab Interuniv Biol Motr, St Etienne, France
[2] Univ Lyon, Univ Claude Bernard Lyon 1, Inst NeuroMyoGene, Unite Physiopathol & Genet Neurone & Muscle,CNRS 5, Lyon, France
[3] Inst Univ France IUF, Paris, France
[4] Schulthess Clin, Human Performance Lab, Zurich, Switzerland
[5] Lab Interuniv Biol Motr, Batiment IRMIS,10 Rue Marandiere, F-42270 St Priest En Jarez, France
关键词
corticospinal excitability; fatigability; motoneuronal excitability; NMES; spinal excitability; MOTOR UNIT RECRUITMENT; PERIPHERAL-NERVE STIMULATION; CORTICOSPINAL EXCITABILITY; CORTEX EXCITABILITY; FEMORIS MUSCLE; FREQUENCY; FATIGUE; CONTRACTIONS; DURATION; FACILITATION;
D O I
10.1111/sms.14375
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: The effectiveness of a neuromuscular electrical stimulation (NMES) program is proportional to the level of evoked torque, which can be achieved with either conventional or wide-pulse stimulations. The aim of this study was to compare evoked torque, objective fatigability, and related peripheral and central alterations, as well as changes in central nervous system (CNS) excitability induced by an acute session of conventional versus wide-pulse NMES. Methods: Seventeen young men underwent three 20-min NMES sessions: conventional (0.2 ms/50 Hz), wide-pulse at 50 Hz (1 ms/50 Hz), and wide-pulse at 100 Hz (1 ms/100 Hz). Neuromuscular measurements (i.e., maximal voluntary contraction, voluntary activation, evoked responses to femoral nerve stimulation, and CNS excitability) were performed on the right quadriceps femoris muscle before and after each NMES session. CNS excitability was measured using transcranial magnetic, thoracic, and transcutaneous spinal cord stimulations. Results: The level of evoked torque was not significantly different between conventional and wide-pulse protocols applied at the maximal tolerable current intensity. All NMES protocols induced objective fatigability (similar to 14% decrease in maximal voluntary contraction torque, p < 0.001) associated with peripheral (decrease in doublet torque and potentiated M-wave amplitude, p = 0.002 and p < 0.001, respectively) but not central (unchanged voluntary activation, p = 0.79) alterations. However, these acute changes did not differ between NMES protocols and none of the NMES protocols modified markers of CNS excitability. Conclusion: These results may allow to conjecture that chronic effects and treatment effectiveness could be comparable between conventional and wide-pulse NMES.
引用
收藏
页码:1307 / 1321
页数:15
相关论文
共 50 条
  • [21] Quadriceps Torque During High- And Low-frequency Neuromuscular Electrical Stimulation
    Magee, Dillon M.
    Mettler, Joni A.
    Doucet, Barbara M.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 1037 - 1037
  • [22] THE EFFECTS OF ACUTE AND REPEATED BOUTS OF UNILATERAL NEUROMUSCULAR ELECTRICAL STIMULATION ON QUADRICEPS MUSCLE INFLAMMATION IN COPD
    Gray, A.
    Latimer, L.
    Parmar, A.
    Bradding, P.
    Greening, N. J.
    Steiner, M. C.
    THORAX, 2015, 70 : A83 - A84
  • [23] Wide-Pulse High-Frequency Neuromuscular Electrical Stimulation Evokes Greater Relative Force in Women Than in Men: A Pilot Study
    Ye, Xin
    Gockel, Nathan
    Vala, Daniel
    Devoe, Teagan
    Brodoff, Patrick
    Gaza, Victor
    Umali, Vinz
    Walker, Hayden
    SPORTS, 2022, 10 (09)
  • [24] Estimation of critical end-test torque using neuromuscular electrical stimulation of the quadriceps in humans
    Janzen, Natalie R.
    Hight, Robert E.
    Patel, Darshit S.
    Campbell, Jason A.
    Larson, Rebecca D.
    Black, Christopher D.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2018, 118 (07) : 1407 - 1414
  • [25] Estimation of critical end-test torque using neuromuscular electrical stimulation of the quadriceps in humans
    Natalie R. Janzen
    Robert E. Hight
    Darshit S. Patel
    Jason A. Campbell
    Rebecca D. Larson
    Christopher D. Black
    European Journal of Applied Physiology, 2018, 118 : 1407 - 1414
  • [26] Acute Effects of Neuromuscular Electrical Stimulation on Vertical Jump
    Kaire, Yusuf K.
    Harveson, Andrew
    Sturz, Dominick
    Garrett, Levi
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 935 - 935
  • [27] Skinfold thickness affects the isometric knee extension torque evoked by Neuromuscular Electrical Stimulation
    Medeiros, Flavia V. A.
    Vieira, Amilton
    Carregaro, Rodrigo L.
    Bottaro, Martim
    Maffiuletti, Nicola A.
    Durigan, Joao L. Q.
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2015, 19 (06) : 466 - 472
  • [28] The role of pulse duration and stimulation duration in maximizing the normalized torque during neuromuscular electrical stimulation
    Gorgey, Ashraf S.
    Dudley, Gary A.
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2008, 38 (08): : 508 - 516
  • [29] Effects of Neuromuscular Electrical Stimulation and Therapeutic Ultrasound on Quadriceps Contracture of Immobilized Rats
    Suwankanit, Kanokwan
    Shimizu, Miki
    VETERINARY SCIENCES, 2024, 11 (04)
  • [30] EFFECTS OF SHORTWAVE DIATHERMY ON THE QUADRICEPS FEMORIS MUSCLE TORQUE DURING NEUROMUSCULAR ELECTRICAL STIMULATION AND VOLUNTARY CONTRACTION IN HEALTHY INDIVIDUALS
    Boldrini, Fabio Chittero
    Lopes, Alexandre Dias
    Liebano, Richard Eloin
    REVISTA BRASILEIRA DE MEDICINA DO ESPORTE, 2013, 19 (04) : 247 - 251