A Comprehensive Mechanical Characterization of Subject-Specific 3D Printed Scaffolds Mimicking Trabecular Bone Architecture Biomechanics

被引:8
作者
Rojas-Rojas, Laura [1 ]
Tozzi, Gianluca [2 ,3 ]
Guillen-Giron, Teodolito [1 ]
机构
[1] Mat Sci & Engn Sch, Tecnol Costa Rica, Cartago 30109, Costa Rica
[2] Univ Greenwich, Sch Engn, Chatham ME4 4TB, England
[3] Univ Portsmouth, Sch Mech & Design Engn, Portsmouth PO1 3DJ, England
来源
LIFE-BASEL | 2023年 / 13卷 / 11期
关键词
polymeric scaffold; trabecular bone; mechanical properties; microCT; digital volume correlation; DIGITAL VOLUME CORRELATION; TISSUE ENGINEERING SCAFFOLDS; IN-VITRO; STRAIN UNCERTAINTIES; BEHAVIOR; BIOMATERIALS; REGENERATION; PROGRESSION; PHYSIOLOGY;
D O I
10.3390/life13112141
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Simple Summary This study aimed at producing a polymeric scaffold with the ability to replicate the structure and mechanical properties of native trabecular bone. The scaffold's morphological characteristics and mechanical parameters were compared to those of trabecular bone from bovine iliac crest. Using a three-step procedure, the elastic modulus and yield strength were investigated, and a dynamic test was performed to evaluate the mechanical behavior under various loading regimes. The local micromechanics of the scaffolds were assessed with in situ microcomputed tomography and digital volume correlation, which measured the full-field strain distribution. Overall, the results showed that the fabricated polymeric scaffold exhibited mechanical properties in the range of trabecular bone and represents a suitable bone surrogate for in vitro applications, with the potential to be further translated for in vivo clinical purposes.Abstract This study presents a polymeric scaffold designed and manufactured to mimic the structure and mechanical compressive characteristics of trabecular bone. The morphological parameters and mechanical behavior of the scaffold were studied and compared with trabecular bone from bovine iliac crest. Its mechanical properties, such as modulus of elasticity and yield strength, were studied under a three-step monotonic compressive test. Results showed that the elastic modulus of the scaffold was 329 MPa, and the one for trabecular bone reached 336 MPa. A stepwise dynamic compressive test was used to assess the behavior of samples under various loading regimes. With microcomputed tomography (mu CT), a three-dimensional reconstruction of the samples was obtained, and their porosity was estimated as 80% for the polymeric scaffold and 88% for trabecular bone. The full-field strain distribution of the samples was measured using in situ mu CT mechanics and digital volume correlation (DVC). This provided information on the local microdeformation mechanism of the scaffolds when compared to that of the tissue. The comprehensive results illustrate the potential of the fabricated scaffolds as biomechanical templates for in vitro studies. Furthermore, there is potential for extending this structure and fabrication methodology to incorporate suitable biocompatible materials for both in vitro and in vivo clinical applications.
引用
收藏
页数:14
相关论文
共 75 条
[21]   BoneJ Free and extensible bone image analysis in ImageJ [J].
Doube, Michael ;
Klosowski, Michal M. ;
Arganda-Carreras, Ignacio ;
Cordelieres, Fabrice P. ;
Dougherty, Robert P. ;
Jackson, Jonathan S. ;
Schmid, Benjamin ;
Hutchinson, John R. ;
Shefelbine, Sandra J. .
BONE, 2010, 47 (06) :1076-1079
[22]   Nondestructive characterization of bone tissue scaffolds for clinical scenarios [J].
Entezari, Ali ;
Zhang, Zhongpu ;
Sue, Andrian ;
Sun, Guangyong ;
Huo, Xintao ;
Chang, Che-Cheng ;
Zhou, Shiwei ;
Swain, Michael V. ;
Li, Qing .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 89 :150-161
[23]   Disorders of Bone Remodeling [J].
Feng, Xu ;
McDonald, Jay M. .
ANNUAL REVIEW OF PATHOLOGY: MECHANISMS OF DISEASE, VOL 6, 2011, 6 :121-145
[24]   Applications of X-ray computed tomography for the evaluation of biomaterial-mediated bone regeneration in critical-sized defects [J].
Fernandez, M. Pena ;
Witte, F. ;
Tozzi, G. .
JOURNAL OF MICROSCOPY, 2020, 277 (03) :179-196
[25]   Optimization of digital volume correlation computation in SR-microCT images of trabecular bone and bone-biomaterial systems [J].
Fernandez, M. Pena ;
Barber, A. H. ;
Blunn, G. W. ;
Tozzi, G. .
JOURNAL OF MICROSCOPY, 2018, 272 (03) :213-228
[26]  
Fuchs RK, 2009, WOODHEAD PUBL MATER, P25, DOI 10.1533/9781845696610.1.25
[27]  
Fucile P, 2019, 2019 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR INDUSTRY 4.0 AND INTERNET OF THINGS (METROIND4.0&IOT), P33, DOI [10.1109/METROI4.2019.8792891, 10.1109/metroi4.2019.8792891]
[28]   Biomechanical behaviours of the bone-implant interface: a review [J].
Gao, Xing ;
Fraulob, Manon ;
Haiat, Guillaume .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2019, 16 (156)
[29]   Microfabrication of complex porous tissue engineering scaffolds using 3D projection stereolithography [J].
Gauvin, Robert ;
Chen, Ying-Chieh ;
Lee, Jin Woo ;
Soman, Pranav ;
Zorlutuna, Pinar ;
Nichol, Jason W. ;
Bae, Hojae ;
Chen, Shaochen ;
Khademhosseini, Ali .
BIOMATERIALS, 2012, 33 (15) :3824-3834
[30]   THE MECHANICAL-BEHAVIOR OF CANCELLOUS BONE [J].
GIBSON, LJ .
JOURNAL OF BIOMECHANICS, 1985, 18 (05) :317-&