Three-Dimensional Anthropometry for Evaluating Philtrum Contour in Patients With Unilateral Cleft Lip: Comparison Between Photographic Assessment and 3-Dimensional Anthropometry
被引:0
作者:
Park, Hojin
论文数: 0引用数: 0
h-index: 0
机构:
Korea Univ, Korea Univ Anam Hosp, Coll Med, Dept Plast Surg, Seoul, South KoreaKorea Univ, Korea Univ Anam Hosp, Coll Med, Dept Plast Surg, Seoul, South Korea
Park, Hojin
[1
]
Min, Jaechung
论文数: 0引用数: 0
h-index: 0
机构:
Onul Plast Surg Clin, Seoul, South KoreaKorea Univ, Korea Univ Anam Hosp, Coll Med, Dept Plast Surg, Seoul, South Korea
Min, Jaechung
[2
]
Koh, Kyung S.
论文数: 0引用数: 0
h-index: 0
机构:
Onul Plast Surg Clin, Seoul, South Korea
Onul Plast Surg Clin, Asan Med Ctr, 596 Gangnam Daero, Seoul 06038, South KoreaKorea Univ, Korea Univ Anam Hosp, Coll Med, Dept Plast Surg, Seoul, South Korea
Koh, Kyung S.
[2
,3
]
机构:
[1] Korea Univ, Korea Univ Anam Hosp, Coll Med, Dept Plast Surg, Seoul, South Korea
[2] Onul Plast Surg Clin, Seoul, South Korea
[3] Onul Plast Surg Clin, Asan Med Ctr, 596 Gangnam Daero, Seoul 06038, South Korea
Philtrum reconstruction in patients with unilateral cleft lip is a major concern in cheiloplasty. Moreover, a quantitative evaluation of the philtrum contour has not been possible. Advances in 3-dimensional (3D) imaging technology have enabled highly accurate assessments of facial surfaces. This study aimed to justify using 3D anthropometric measurements to quantify traditional photographic grading systems. Sixty-six children with unilateral cleft lip, aged 4 to 6 years (mean age: 69.1 +/- 5.7 mo), who visited the outpatient clinic from January to December 2020 were included. A plastic surgeon panel graded the philtrum contour using digital photographs, and 3D anthropometry was performed using a 3D imaging system. The philtrum height, philtrum height difference, and dimple depth were measured at the middle of the philtrum. The philtrum height did not show significant changes across the photographic scores (P=0.06), whereas noticeable differences were observed in the dimple depths based on photographic scores (P<0.001). The correlation analysis revealed the highest correlation between the photographic score and dimple depth (rho=0.897, P<0.001). The philtrum height on the cleft side (rho=0.478, P<0.001) also correlated with the photographic score, but the correlation was weaker than that of the dimple depth. The dimple depth and philtrum height can help define the philtrum contour. Furthermore, the dimple depth reflects the philtrum contour better and is more suitable as a single parameter. However, relying on a single philtrum height measurement may be insufficient for reliable evaluations, as the relative height from the surrounding tissues is more important than the absolute height measured using 3D anthropometry.
机构:
Seoul Natl Univ, Coll Med, Dept Plast & Reconstruct Surg, Inst Human Environm Interface Biol, Seoul 110744, South KoreaSeoul Natl Univ, Coll Med, Dept Plast & Reconstruct Surg, Inst Human Environm Interface Biol, Seoul 110744, South Korea
Kim, Sukwha
Kwon, Juyong
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Coll Med, Dept Plast & Reconstruct Surg, Inst Human Environm Interface Biol, Seoul 110744, South KoreaSeoul Natl Univ, Coll Med, Dept Plast & Reconstruct Surg, Inst Human Environm Interface Biol, Seoul 110744, South Korea
Kwon, Juyong
Kwon, Geun-Yong
论文数: 0引用数: 0
h-index: 0
机构:
Korea Ctr Dis Control & Prevent, Div Epidem Intelligence Serv, Osong, South KoreaSeoul Natl Univ, Coll Med, Dept Plast & Reconstruct Surg, Inst Human Environm Interface Biol, Seoul 110744, South Korea
Kwon, Geun-Yong
Choi, Tae Hyun
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Coll Med, Dept Plast & Reconstruct Surg, Inst Human Environm Interface Biol, Seoul 110744, South KoreaSeoul Natl Univ, Coll Med, Dept Plast & Reconstruct Surg, Inst Human Environm Interface Biol, Seoul 110744, South Korea
机构:
Seoul Natl Univ, Coll Med, Dept Plast & Reconstruct Surg, Inst Human Environm Interface Biol, Seoul 110744, South KoreaSeoul Natl Univ, Coll Med, Dept Plast & Reconstruct Surg, Inst Human Environm Interface Biol, Seoul 110744, South Korea
Kim, Sukwha
Kwon, Juyong
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Coll Med, Dept Plast & Reconstruct Surg, Inst Human Environm Interface Biol, Seoul 110744, South KoreaSeoul Natl Univ, Coll Med, Dept Plast & Reconstruct Surg, Inst Human Environm Interface Biol, Seoul 110744, South Korea
Kwon, Juyong
Kwon, Geun-Yong
论文数: 0引用数: 0
h-index: 0
机构:
Korea Ctr Dis Control & Prevent, Div Epidem Intelligence Serv, Osong, South KoreaSeoul Natl Univ, Coll Med, Dept Plast & Reconstruct Surg, Inst Human Environm Interface Biol, Seoul 110744, South Korea
Kwon, Geun-Yong
Choi, Tae Hyun
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Coll Med, Dept Plast & Reconstruct Surg, Inst Human Environm Interface Biol, Seoul 110744, South KoreaSeoul Natl Univ, Coll Med, Dept Plast & Reconstruct Surg, Inst Human Environm Interface Biol, Seoul 110744, South Korea