Enabling ultra-high dose rate electron beams at a clinical linear accelerator for isocentric treatments

被引:17
作者
Dal Bello, Riccardo [1 ,2 ,4 ]
von der Grun, Jens [1 ,2 ]
Fabiano, Silvia [1 ,2 ]
Rudolf, Thomas [1 ,2 ]
Saltybaeva, Natalia [1 ,2 ]
Stark, Luisa S. [1 ,2 ]
Ahmed, Md [3 ]
Bathula, Manohar [3 ]
Dogan, Serpil Kucuker [3 ]
McNeur, Joshua [3 ]
Guckenberger, Matthias [1 ,2 ]
Tanadini-Lang, Stephanie [1 ,2 ]
机构
[1] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
[2] Univ Zurich, Zurich, Switzerland
[3] Siemens Healthineers Co, Varian Med Syst, Palo Alto, CA USA
[4] Univ Spital Zurich USZ, Klin Radioonkol, Ramistr 100, CH-8091 Zurich, Switzerland
关键词
Ultra -high dose rate; FLASH; Electron beam; Linac; Radiotherapy; RADIATION TOXICITY; FLASH IRRADIATION; DOSIMETRY; MICE;
D O I
10.1016/j.radonc.2023.109822
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and Purpose: Radiotherapy delivery with ultra-high dose rates (UHDR) has consistently produced normal tissue sparing while maintaining efficacy for tumour control in preclinical studies, known as the FLASH effect. Modified clinical electron linacs have been used for pre-clinical studies at reduced source-surface distance (SSD) and novel intra-operative devices are becoming available. In this context, we modified a clinical linac to deliver 16 MeV UHDR electron beams with an isocentric setup.Materials and Methods: The first Varian TrueBeam (SN 1001) was clinically operative between 2009- 2022, it was then decommissioned and converted into a research platform. The 18 MeV electron beam was converted into the experimental 16 MeV UHDR. Modifications were performed by Varian and included a software patch, thinner scattering foil and beam tuning. The dose rate, beam characteristics and reproducibility were measured with electron applicators at SSD = 100 cm.Results: The dose per pulse at isocenter was up to 1.28 Gy/pulse, corresponding to average and instantaneous dose rates up to 256 Gy/s and 3.105 Gy/s, respectively. Beam characteristics were equivalent between 16 MeV UHDR and conventional for field sizes up to 10x10cm2 and an overall beam reproducibility within & PLUSMN; 2.5% was measured.Conclusions: We report on the first technical conversion of a Varian TrueBeam to produce 16 MeV UHDR electron beams. This research platform will allow isocenter experiments and deliveries with conventional setups up to field sizes of 10x10 cm2 within a hospital environment, reducing the gap between preclinical and clinical electron FLASH investigations.& COPY; 2023 The Author(s). Published by Elsevier B.V. Radiotherapy and Oncology 187 (2023) 109822 This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:7
相关论文
共 47 条
  • [21] Response of diamond detectors in ultra-high dose-per-pulse electron beams for dosimetry at FLASH radiotherapy
    Kranzer, R.
    Schueller, A.
    Bourgouin, A.
    Hackel, T.
    Poppinga, D.
    Lapp, M.
    Looe, H. K.
    Poppe, B.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (07)
  • [22] Modifying a clinical linear accelerator for delivery of ultra-high dose rate irradiation
    Lempart, Michael
    Blad, Borje
    Adrian, Gabriel
    Back, Sven
    Knoos, Tommy
    Ceberg, Crister
    Petersson, Kristoffer
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 139 : 40 - 45
  • [23] Abdominal FLASH irradiation reduces radiation-induced gastrointestinal toxicity for the treatment of ovarian cancer in mice
    Levy, Karen
    Natarajan, Suchitra
    Wang, Jinghui
    Chow, Stephanie
    Eggold, Joshua T.
    Loo, Phoebe E.
    Manjappa, Rakesh
    Melemenidis, Stavros
    Lartey, Frederick M.
    Schueler, Emil
    Skinner, Lawrie
    Rafat, Marjan
    Ko, Ryan
    Kim, Anna
    Al-Rawi, Duaa H.
    von Eyben, Rie
    Dorigo, Oliver
    Casey, Kerriann M.
    Graves, Edward E.
    Bush, Karl
    Yu, Amy S.
    Koong, Albert C.
    Maxim, Peter G.
    Loo, Billy W., Jr.
    Rankin, Erinn B.
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [24] Dual beam-current transformer design for monitoring and reporting of electron ultra-high dose rate (FLASH) beam parameters
    Liu, Kevin
    Palmiero, Allison
    Chopra, Nitish
    Velasquez, Brett
    Li, Ziyi
    Beddar, Sam
    Schueler, Emil
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (02):
  • [25] Proton FLASH Radiotherapy for the Treatment of Symptomatic Bone Metastases The FAST-01 Nonrandomized Trial
    Mascia, Anthony E.
    Daugherty, Emily C.
    Zhang, Yongbin
    Lee, Eunsin
    Xiao, Zhiyan
    Sertorio, Mathieu
    Woo, Jennifer
    Backus, Lori R.
    McDonald, Julie M.
    McCann, Claire
    Russell, Kenneth
    Levine, Lisa
    Sharma, Ricky A.
    Khuntia, Dee
    Bradley, Jeffrey D.
    Simone, Charles B.
    Perentesis, John P.
    Breneman, John C.
    [J]. JAMA ONCOLOGY, 2023, 9 (01) : 62 - 69
  • [26] Commissioning of an ultra-high dose rate pulsed electron beam medical LINAC for FLASH RT preclinical animal experiments and future clinical human protocols
    Moeckli, Raphael
    Jorge, Patrik Goncalves
    Grilj, Veljko
    Oesterle, Roxane
    Cherbuin, Nicolas
    Bourhis, Jean
    Vozenin, Marie-Catherine
    Germond, Jean-Francois
    Bochud, Francois
    Bailat, Claude
    [J]. MEDICAL PHYSICS, 2021, 48 (06) : 3134 - 3142
  • [27] Hypofractionated FLASH-RT as an Effective Treatment against Glioblastoma that Reduces Neurocognitive Side Effects in Mice
    Montay-Gruel, Pierre
    Acharya, Munjal M.
    Jorge, Patrik Goncalves
    Petit, Benoit
    Petridis, Ioannis G.
    Fuchs, Philippe
    Leavitt, Ron
    Petersson, Kristoffer
    Gondre, Maude
    Ollivier, Jonathan
    Moeckli, Raphael
    Bochud, Francois
    Bailat, Claude
    Bourhis, Jean
    Germond, Jean-Francois
    Limoli, Charles L.
    Vozenin, Marie-Catherine
    [J]. CLINICAL CANCER RESEARCH, 2021, 27 (03) : 775 - 784
  • [28] Long-term neurocognitive benefits of FLASH radiotherapy driven by reduced reactive oxygen species
    Montay-Gruel, Pierre
    Acharya, Munjal M.
    Petersson, Kristoffer
    Alikhani, Leila
    Yakkala, Chakradhar
    Allen, Barrett D.
    Ollivier, Jonathan
    Petit, Benoit
    Jorge, Patrik Goncalves
    Syage, Amber R.
    Nguyen, Thuan A.
    Baddour, Al Anoud D.
    Lu, Celine
    Singh, Paramvir
    Moeckli, Raphael
    Bochud, Francois
    Germond, Jean-Francois
    Froidevaux, Pascal
    Bailat, Claude
    Bourhis, Jean
    Vozenin, Marie-Catherine
    Limoli, Charles L.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2019, 116 (22) : 10943 - 10951
  • [29] Irradiation in a flash: Unique sparing of memory in mice after whole brain irradiation with dose rates above 100 Gy/s
    Montay-Gruel, Pierre
    Petersson, Kristoffer
    Jaccard, Maud
    Boivin, Gael
    Germond, Jean-Francois
    Petit, Benoit
    Doenlen, Raphael
    Favaudon, Vincent
    Bochud, Francois
    Bailat, Claude
    Bourhis, Jean
    Vozenin, Marie-Catherine
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 124 (03) : 365 - 369
  • [30] Pelvic Radiation and Normal Tissue Toxicity
    Nicholas, Sarah
    Chen, Linda
    Choflet, Amanda
    Fader, Amanda
    Guss, Zachary
    Hazell, Sarah
    Song, Daniel Y.
    Tran, Phuoc T.
    Viswanathan, Akila N.
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2017, 27 (04) : 358 - 369