Diagnostic value and safety of ultrathin bronchoscope and endobronchial ultrasonography with a guide sheath combined with rapid on-site evaluation system for peripheral pulmonary infectious diseases

被引:4
作者
Liang, Yongxue [1 ]
Jiang, Xia [1 ]
Ma, Liwen [1 ]
LI, Yi [1 ]
Ma, Han [1 ]
Wang, Zhongping [1 ]
机构
[1] Yanan Hosp Kunming City, Ward Resp & Crit Care Med 2, Kunming, Peoples R China
来源
MINERVA SURGERY | 2023年 / 78卷 / 01期
关键词
Infectious disease medicine; Bronchoscopes; Ultrasonography; Rapid on-site evaluation; THIN BRONCHOSCOPE; LESIONS;
D O I
10.23736/S2724-5691.22.09597-1
中图分类号
R61 [外科手术学];
学科分类号
摘要
BACKGROUND: The aim of this study was to investigate the diagnostic value and safety of ultrathin bronchoscope and endobronchial ultrasonography with a guide sheath (EBUS-GS) combined with rapid on-site evaluation (ROSE) system for peripheral pulmonary infectious diseases.METHODS: The clinical data of 196 patients visiting our hospital, who had peripheral pulmonary lesions (PPLs) indi-cated by spiral computed tomography (CT) of the chest and were finally diagnosed as infectious PPLs, were retrospec-tively collected. Then the patients were divided into ultrathin bronchoscope + ROSE group, EBUS-GS + ROSE group and ultrathin bronchoscope + EBUS-GS + ROSE group based on different diagnostic techniques. Moreover, the general conditions, diagnostic results and specific operation parameters of the patients were recorded, and the diagnostic rate, sensitivity and complications were compared.RESULTS: In ultrathin bronchoscope + EBUS-GS + ROSE group, the time of localizing lesions and operation time were the shortest, and the grade of bronchi reached by the bronchoscope was the highest. The differences were significant between any two groups (P<0.05). Patients with bacterial pneumonia, and patients with pulmonary tuberculosis and nontuberculous mycobacterial disease, ultrathin bronchoscope + EBUS-GS + ROSE group exhibited the highest definite diagnosis rate of bronchoscope and diagnostic sensitivity of ROSE system, with significant differences from those of the other two groups (P<0.05). The incidence rates of complications were low in all groups, and there were no significant differences between any two groups (P>0.05).CONCLUSIONS: Ultrathin bronchoscope and EBUS-GS combined with ROSE system can prominently decrease the time of localizing lesions and operation time, remarkably improve the diagnostic accuracy and sensitivity and result in fewer complications.
引用
收藏
页码:37 / 44
页数:8
相关论文
共 13 条
  • [1] Diagnostic Yield of the Virtual Bronchoscopic Navigation System Guided Sampling of Peripheral Lung Lesions using Ultrathin Bronchoscope and Protected Bronchial Brush
    Biswas, Abhishek
    Mehta, Hiren J.
    Sriram, P. S.
    [J]. TURKISH THORACIC JOURNAL, 2019, 20 (01) : 6 - 11
  • [2] Furihata K., 2018, ANN CANCER RES THER, V26, P11
  • [3] Multiple guided technologies based on radial probe endobronchial ultrasound for the diagnosis of solitary peripheral pulmonary lesions: a single-center study
    Huang Haidong
    Ning Yunye
    Zhang Wei
    Zarogoulidis, Paul
    Hohenforst-Schmidt, Wolfgang
    Man, Yan-Gao
    Yang Yuguang
    Dong Yuchao
    Bai Chong
    [J]. JOURNAL OF CANCER, 2017, 8 (17): : 3514 - 3521
  • [4] Clinical outcomes of radial probe endobronchial ultrasound using a guide sheath for diagnosis of peripheral lung lesions in patients with pulmonary emphysema
    Lee, Kyu Min
    Lee, Geewon
    Kim, Ahreum
    Mok, Jeongha
    Lee, Ji Won
    Jeong, Yeon Joo
    Jo, Eun-Jung
    Kim, Mi Hyun
    Lee, Kwangha
    Kim, Ki Uk
    Park, Hye-Kyung
    Lee, Min Ki
    Eom, Jung Seop
    [J]. RESPIRATORY RESEARCH, 2019, 20 (01)
  • [5] [李士杰 Li Shijie], 2019, [中国肺癌杂志, Chinese Journal of Lung Cancer], V22, P125
  • [6] Metagenomic next-generation sequencing diagnosis of peripheral pulmonary infectious lesions through virtual navigation, radial EBUS, ultrathin bronchoscopy, and ROSE
    Liu, Nana
    Kan, Jianying
    Cao, Wenbin
    Cao, Jie
    Jiang, Erlie
    Zhou, Yang
    Zhao, Mingfeng
    Feng, Jing
    [J]. JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (10) : 4878 - 4885
  • [7] Use of an Ultrathin vs Thin Bronchoscope for Peripheral Pulmonary Lesions A Randomized Trial
    Oki, Masahide
    Saka, Hideo
    Asano, Fumihiro
    Kitagawa, Chiyoe
    Kogure, Yoshihito
    Tsuzuku, Akifumi
    Ando, Masahiko
    [J]. CHEST, 2019, 156 (05) : 954 - 964
  • [8] Needle Biopsy Adequacy in the Era of Precision Medicine and Value-Based Health Care
    Pritzker, Kenneth P. H.
    Nieminen, Heikki J.
    [J]. ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2019, 143 (11) : 1399 - 1415
  • [9] Bronchoscopic pursuit of the peripheral pulmonary lesion: navigational bronchoscopy, radial endobronchial ultrasound, and ultrathin bronchoscopy
    Shepherd, Ray W.
    [J]. CURRENT OPINION IN PULMONARY MEDICINE, 2016, 22 (03) : 257 - 264
  • [10] Diagnostic utility and accuracy of rapid on-site evaluation of bronchoscopic brushings
    Steinfort, Daniel P.
    Leong, Tracy L.
    Laska, Irena F.
    Beaty, Anne
    Tsui, Alpha
    Irving, Louis B.
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2015, 45 (06) : 1653 - 1660