Clinical utility of remote monitoring for patients with cardiac implantable electrical devices

被引:2
|
作者
Yang, Shu [1 ,2 ]
Stabenau, Hans F. [1 ,2 ]
Kiernan, Katherine [1 ,2 ]
Diamond, Jamie E. [1 ,2 ]
Kramer, Daniel B. [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Richard A & Susan F Smith Ctr Outcomes Res Cardio, 375 Longwood Ave,4th Floor, Boston, MA 02215 USA
[2] Harvard Med Sch, Boston, MA 02115 USA
关键词
Remote monitoring; Pacemaker; Implantable cardiac defibrillator; FOLLOW-UP; ELECTRONIC DEVICES; EXPERT CONSENSUS; ADHERENCE; TIME;
D O I
10.1007/s10840-022-01406-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Remote monitoring of cardiac implantable electronic devices (CIEDs) offers practical and clinical benefits juxtaposed against burdens associated with high transmission volume. Methods We identified patients receiving de novo pacemakers (PPMs) and implantable cardiac defibrillators (ICDs) at a single academic medical center (January 2016-December 2019) with at least 1 year of follow-up device care. We collected patient- and device-specific data at time of implant and assessed all remote and in-person interrogation reports for clinically actionable findings based on pre-specified criteria. Results Among 963 patients (mean age of 71 (+/- 14) years, 37% female), 655 (68%) underwent PPM, and 308 (32%) underwent ICD implant. Median follow-up was 874 (627-1221) days, during which time patients underwent a mean of 13 (10-16) total interrogations; remote interrogations comprised 53% of all device evaluations; and of these, 96% were scheduled transmissions. Overall, 22% of all CIED interrogations yielded significant findings with a slightly higher rate in the PPM than in the ICD group (23% vs. 20%, p < 0.01). Only 8% of remote interrogations produced clinically meaningful results, compared with 38% of in-person ones. In adjusted models, routine, remote transmissions were least likely to be useful for both PPM and ICD patients (p< 0.001), whereas time from initial device implant was inversely associated with probability of obtaining a useful interrogation (p < 0.001). Conclusions Routine remote interrogations constitute the majority of device evaluations performed, but uncommonly identify clinically actionable findings.
引用
收藏
页码:961 / 969
页数:9
相关论文
共 50 条
  • [41] Remote Monitoring of Cardiac Implantable Electronic Devices Helping Our Patients Get Online and Stay Connected
    Ganesan, Anand N.
    Tiver, Kathryn D.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2024, 10 (02) : 331 - 333
  • [42] Remote Monitoring of Cardiac Implantable Electronic Devices: What is the Evidence?
    Reinhardt, Adrian
    Ventura, Rodolfo
    CURRENT HEART FAILURE REPORTS, 2023, 20 (01) : 12 - 23
  • [43] Health Care Utilization and Expenditures Associated With Remote Monitoring in Patients With Implantable Cardiac Devices
    Ladapo, Joseph A.
    Turakhia, Mintu P.
    Ryan, Michael P.
    Mollenkopf, Sarah A.
    Reynolds, Matthew R.
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 117 (09) : 1455 - 1462
  • [44] Remote monitoring of patients with cardiac implantable electronic devices: maximizing gains by addressing workflow
    Varma, Niraj
    EUROPACE, 2013, 15 (07): : 921 - 923
  • [45] Utilization of the remote monitoring of cardiac implantable electronic devices in a diverse demographic cohort: Insights from a single-center observation
    Seo, Jiyoung
    Alhuarrat, Majd Al Deen
    Krishnan, Suraj
    Saralidze, Tinatin
    Lim, Hyomin
    Chen, Brett
    Flomenbaum, David
    Naser, Ahmad
    Kharawala, Amrin
    Apple, Samuel J.
    Ferrick, Neal
    Chudow, Jay
    Di Biase, Luigi
    Fisher, John D.
    Krumerman, Andrew
    Ferrick, Kevin J.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (02): : 185 - 194
  • [46] Clinical Research Clinical and Economic Outcomes Associated With Remote Monitoring for Cardiac Implantable Electronic Devices: A Population-Based Analysis
    Chew, Derek S.
    Zarrabi, Mahmood
    You, Isabelle
    Morton, James
    Low, Aaron
    Reyes, Lucy
    Yuen, Brian
    Sumner, Glen L.
    Raj, Satish R.
    Exner, Derek, V
    Wilton, Stephen B.
    CANADIAN JOURNAL OF CARDIOLOGY, 2022, 38 (06) : 736 - 744
  • [47] Remote monitoring of cardiovascular implantable electronic devices
    Sticherling, Christian
    Kuehne, Michael
    Schaer, Beat
    Altmann, David
    Osswald, Stefan
    SWISS MEDICAL WEEKLY, 2009, 139 (41-42) : 596 - 601
  • [48] Remote monitoring of implantable devices: Should we continue to ignore it?
    Bertini, Matteo
    Marcantoni, Lina
    Toselli, Tiziano
    Ferrari, Roberto
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 202 : 368 - 377
  • [49] Technical Reliability and Clinical Safety of a Remote Monitoring System for Antiarrhythmic Cardiac Devices
    Osca, Joaquin
    Sancho Tello, Maria Jose
    Navarro, Josep
    Cano, Oscar
    Raso, Rafael
    Enrique Castro, Jose
    Olaguee, Jose
    Salvador, Antonio
    REVISTA ESPANOLA DE CARDIOLOGIA, 2009, 62 (08): : 886 - 895
  • [50] Is it feasible to outsource the remote monitoring of implantable cardiac defibrillators in a large tertiary hospital?
    Lapage, Liesbeth
    Foulon, Stefaan
    Poels, Patricia
    Hoekman, Boukje
    Vermeulen, Jonas
    Dorrestijn, Axel
    Ector, Joris
    Haemers, Peter
    Voros, Gabor
    Garweg, Christophe
    Willems, Rik
    ACTA CARDIOLOGICA, 2023, 78 (06) : 687 - 698