Intrarater reliability of cervical range of motion device among adults with and without chronic non-specific neck pain

被引:0
|
作者
Akhter, Saeed [1 ]
Zafar, Hamayun [2 ]
Ahmad, Ashfaq [2 ]
Farooqui, Waqas Ahmed [3 ]
机构
[1] Sindh Inst Phys Med & Rehabil, Dept Physiotherapy, Karachi, Pakistan
[2] Univ Lahore, Univ Inst Clin & Ctr Res Phys Therapy, Lahore, Pakistan
[3] Dow Univ Hlth Sci, Sch Publ Hlth, Karachi, Pakistan
关键词
Reliability; Range of motion; Spinal column; Non-specific neck pain; ACTIVE RANGE; CROM DEVICE; VALIDITY;
D O I
10.47391/JPMA.9551
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the intrarater reliability of the cervical range of motion device among adults with and without chronic non-specific neck pain. Method: The analytical, cross-sectional study was conducted from January to March 2019 at the Sindh Institute of Physical Medicine and Rehabilitation, Karachi, and comprised healthy adults with no neck pain in the preceding 6 months in Group A, and adults of either gender with chronic non-specific neck pain for >3 months in Group B. The two groups were further divided into age groups 21-30 years, 31-40 years and 41-50 years. A cervical range of motion device was used to measure the range of flexion, extension, right and left lateral flexion and right and left rotation of all the subjects. The measurements were taken by a single tester on day-1 and day-3 to assess the intrarater reliability. Data was analysed using SPSS 26. Results: Of the 60 subjects, there were 30(50%) in each of the two groups. Within the groups, there were 10(33.3%) subjects in each of the 3 age subgroups. Overall, there were 27(45%) males and 33(55%) females. In Group A, the intraclass correlation coefficient values for all cervical ranges were between 0.81 and 0.99, whereas in Group B, the values ranged from 0.64 to 0.88. The intraclass correlation coefficient values yielded good to excellent agreement in both groups (>0.75) except for left lateral flexion in Group B (p=0.64), and all the values were statistically significant (p<0.05). Conclusion: There was good to excellent intrarater reliability of cervical range of motion device in adults with and without chronic non-specific neck pain.
引用
收藏
页码:2017 / 2022
页数:6
相关论文
共 50 条
  • [41] COMPARISON BETWEEN NECK PAIN DISABILITY AND CERVICAL RANGE OF MOTION IN PATIENTS WITH EPISODIC AND CHRONIC MIGRAINE: A CROSS-SECTIONAL STUDY
    Carvalho, Gabriela F.
    Chaves, Thais C.
    Goncalves, Maria C.
    Florencio, Lidiane L.
    Braz, Carolina A.
    Dach, Fabiola
    de Las Penas, Cesar Fernandez
    Bevilaqua-Grossi, Debora
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2014, 37 (09) : 641 - 646
  • [42] Intra- and inter-rater reliability, standard error of measurement, and minimal detectable change of the cranio-cervical flexion test in individuals with non-specific chronic neck pain
    Broisler, Camila N.
    Gaban, Giovanna L. N. A.
    Vivaldini, Maria R. S.
    Nunes, Giovanna S.
    Selistre, Luiz F. A.
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2025, 76
  • [43] Validity and Reliability of the Greek Version of Pittsburgh Sleep Quality Index in Chronic Non-Specific Low Back Pain Patients
    Petropoulakos, Kyriakos
    Papakonstantinou, Vasiliki
    Pentsi, Smaragda
    Souzou, Eftychia
    Dimitriadis, Zacharias
    Billis, Evdokia
    Koumantakis, Georgios
    Poulis, Ioannis
    Spanos, Savvas
    HEALTHCARE, 2024, 12 (05)
  • [44] Investigation of the relationship between wearing glasses and deep cervical flexor endurance in patients with non-specific neck pain
    Naz, Ilknur
    Yildirim, Yucel
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2010, 23 (03) : 143 - 149
  • [45] Reliability and group differences in quantitative cervicothoracic measures among individuals with and without chronic neck pain
    Bahar Shahidi
    Cynthia L Johnson
    Douglas Curran-Everett
    Katrina S Maluf
    BMC Musculoskeletal Disorders, 13
  • [46] Manual therapy versus therapeutic exercise in non-specific chronic neck pain: a randomized controlled trial
    Bernal-Utrera, Carlos
    Jose Gonzalez-Gerez, Juan
    Anarte-Lazo, Ernesto
    Rodriguez-Blanco, Cleofas
    TRIALS, 2020, 21 (01)
  • [47] Efficacy of neck stabilization and Pilates exercises on pain, sleep disturbance and kinesiophobia in patients with non-specific chronic neck pain: A randomized controlled trial
    Akodu, A. K.
    Nwanne, C. A.
    Fapojuwo, O. A.
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2021, 26 : 411 - 419
  • [48] To What Degree Does Active Cervical Range of Motion Differ Between Patients With Neck Pain, Patients With Whiplash, and Those Without Neck Pain? A Systematic Review and Meta-Analysis
    Stenneberg, Martijn S.
    Rood, Michiel
    de Bie, Rob
    Schmitt, Maarten A.
    Cattrysse, Erik
    Scholten-Peeters, Gwendolijne G.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2017, 98 (07): : 1407 - 1434
  • [49] Vacuum myofascial therapy device for non-specific neck pain. A single blind randomized clinical trial
    Rodriguez-Huguet, Manuel
    Rodriguez-Huguet, Pablo
    Lomas-Vega, Rafael
    Ibanez-Vera, Alfonso Javier
    Rodriguez-Almagro, Daniel
    COMPLEMENTARY THERAPIES IN MEDICINE, 2020, 52
  • [50] The Predictive Value and Influencing Factors of Craniocervical Flexion Test for Patients with Chronic Non-Specific Neck Pain: A Case Control Study
    Wu, Maodong
    Yi, Wenchao
    Su, Qinglun
    Huang, Yiming
    Zhao, Qin
    Liu, Shouguo
    JOURNAL OF PAIN RESEARCH, 2024, 17 : 3817 - 3828