Experimental analyses of solidification phenomena in an ice-based thermal energy storage system

被引:3
作者
Sharma, Amrita [1 ]
Abhinand, S. [1 ]
Kothadia, Hardik [1 ]
Singh, Shobhana [1 ]
Mondal, Bobin [2 ]
机构
[1] Indian Inst Technol, Dept Mech Engn, Jodhpur, India
[2] Def Lab Jodhpur, DRDO, Jodhpur, India
关键词
Ice thermal storage system; Tube; -in; -tank; Solidification; Thermal performance; Heat transfer characteristics; Natural convection; AIR-CONDITIONING SYSTEMS; PHASE-CHANGE; COOLING SYSTEM; PERFORMANCE; PCM; BUILDINGS; WATER; COIL;
D O I
10.1016/j.applthermaleng.2023.121888
中图分类号
O414.1 [热力学];
学科分类号
摘要
Latent thermal energy storage devices can efficiently store surplus thermal energy during off-peak hours. The system's phase change material (PCM) improves energy storage capacity and isothermal properties. Most PCMs have weak thermal conductivity, which hampers heat transfer. Thus, the present analysis involves an insight into the heat transfer characteristics and thermal performance of a vertical tube-in-tank cold storage system. The objective of this investigation is to gain a better understanding of the significance of buoyancy-driven convection within the side bulk region during the discharging of water as PCM in the heat exchanger. A series of experiments are conducted to investigate the effect of varying the initial bulk temperature on the rate of PCM solidification. The effects of three distinct initial bulk temperatures which are 20 degrees C, 15 degrees C, and 5 degrees C on the solidified mass fraction, thermal performance, and heat transfer rate at various radial and axial locations in PCM are examined. It is seen that PCM experienced a varying cooling rate with varying axial height and is found to be the highest in the bottom region. PCM temperature decreases from top to bottom under the cases of 20 degrees C and 15 degrees C, respectively. In contrast, a narrow-ranged thermocline layer is observed under 5 degrees C bulk temperature, making uniform temperature distribution within the bulk. The influence of bulk natural convection prevails in the later stages of the discharging process under 5 degrees C bulk, whereas it predominantly exists during the initial stages of solidification under bulk temperatures of 20 degrees C and 15 degrees C.
引用
收藏
页数:17
相关论文
共 37 条
[1]   Experimental investigations on the thermal performance of an ice storage system using twin concentric helical coil [J].
Abdelrahman, H. E. ;
Refaey, H. A. ;
Alotaibi, A. ;
Abdel-Aziz, Ali A. ;
Abd Rabbo, M. F. .
APPLIED THERMAL ENGINEERING, 2020, 179
[2]   Experimental investigation of ice melting system with open and closed ice-storage tanks combined internal and external ice melting processes [J].
Bi, Yuehong ;
Yu, Meize ;
Wang, Hongyan ;
Huang, Jiabin ;
Lyu, Tianli .
ENERGY AND BUILDINGS, 2019, 194 :12-20
[3]   Thermal analysis of a water source heat pump for space heating using an outdoor pool as a heat source [J].
Cardemil, J. M. ;
Schneider, W. ;
Behzad, M. ;
Starke, A. R. .
JOURNAL OF BUILDING ENGINEERING, 2021, 33
[4]   Performance evaluation of district cooling plant with ice storage [J].
Chan, Apple L. S. ;
Chow, Tin-Tai ;
Fong, Square K. F. ;
Lin, John Z. .
ENERGY, 2006, 31 (14) :2750-2762
[5]   Influence of the size of spherical capsule on solidification characteristics of DI (deionized water) water for a cool thermal energy storage system - An experimental study [J].
Chandrasekaran, P. ;
Cheralathan, M. ;
Velraj, R. .
ENERGY, 2015, 90 :807-813
[6]   Optimal energy management of smart building for peak shaving considering multi-energy flexibility measures [J].
Chen, Lu ;
Xu, Qingshan ;
Yang, Yongbiao ;
Song, Jing .
ENERGY AND BUILDINGS, 2021, 241
[7]   Optimal deployment of thermal energy storage under diverse economic and climate conditions [J].
DeForest, Nicholas ;
Mendes, Goncalo ;
Stadler, Michael ;
Feng, Wei ;
Lai, Judy ;
Marnay, Chris .
APPLIED ENERGY, 2014, 119 :488-496
[8]   Energy and exergy analyses of an ice-on-coil thermal energy storage system [J].
Ezan, Mehmet Akif ;
Erek, Aytunc ;
Dincer, Ibrahim .
ENERGY, 2011, 36 (11) :6375-6386
[9]   Innovative control logics for a rational utilization of electric loads and air-conditioning systems in a residential building [J].
Graditi, G. ;
Ippolito, M. G. ;
Lamedica, R. ;
Piccolo, A. ;
Ruvio, A. ;
Santinic, E. ;
Siano, P. ;
Zizzo, G. .
ENERGY AND BUILDINGS, 2015, 102 :1-17
[10]   An experimental study on ice formation around horizontal long tubes [J].
Habeebullah, Badr A. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (05) :789-797