Automated segmentation of long and short axis DENSE cardiovascular magnetic resonance for myocardial strain analysis using spatio-temporal convolutional neural networks

被引:11
作者
Barbaroux, Hugo [1 ,2 ]
Kunze, Karl P. [4 ]
Neji, Radhouene [4 ]
Nazir, Muhummad Sohaib [1 ]
Pennell, Dudley J. [2 ,3 ]
Nielles-Vallespin, Sonia [2 ,3 ]
Scott, Andrew D. [2 ,3 ]
Young, Alistair A. [1 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
[2] Guys & St Thomas NHS Fdn Trust, Royal Brompton Hosp, Cardiovasc Magnet Resonance Unit, London, England
[3] Imperial Coll London, Natl Heart & Lung Inst, London, England
[4] Siemens Healthcare Ltd, MR Res Collaborat, Camberley, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
Cardiac; MRI; Strain; DENSE; Deep learning; Spatio-temporal; Segmentation; GLOBAL LONGITUDINAL STRAIN; LEFT-VENTRICULAR FUNCTION; CARDIAC MOTION ANALYSIS; ADULT PATIENTS; NNU-NET; ECHOCARDIOGRAPHY; MECHANICS; TRACKING; DYSFUNCTION; BREAST;
D O I
10.1186/s12968-023-00927-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundCine Displacement Encoding with Stimulated Echoes (DENSE) facilitates the quantification of myocardial deformation, by encoding tissue displacements in the cardiovascular magnetic resonance (CMR) image phase, from which myocardial strain can be estimated with high accuracy and reproducibility. Current methods for analyzing DENSE images still heavily rely on user input, making this process time-consuming and subject to inter-observer variability. The present study sought to develop a spatio-temporal deep learning model for segmentation of the left-ventricular (LV) myocardium, as spatial networks often fail due to contrast-related properties of DENSE images.Methods2D + time nnU-Net-based models have been trained to segment the LV myocardium from DENSE magnitude data in short- and long-axis images. A dataset of 360 short-axis and 124 long-axis slices was used to train the networks, from a combination of healthy subjects and patients with various conditions (hypertrophic and dilated cardiomyopathy, myocardial infarction, myocarditis). Segmentation performance was evaluated using ground-truth manual labels, and a strain analysis using conventional methods was performed to assess strain agreement with manual segmentation. Additional validation was performed using an externally acquired dataset to compare the inter- and intra-scanner reproducibility with respect to conventional methods.ResultsSpatio-temporal models gave consistent segmentation performance throughout the cine sequence, while 2D architectures often failed to segment end-diastolic frames due to the limited blood-to-myocardium contrast. Our models achieved a DICE score of 0.83 +/- 0.05 and a Hausdorff distance of 4.0 +/- 1.1 mm for short-axis segmentation, and 0.82 +/- 0.03 and 7.9 +/- 3.9 mm respectively for long-axis segmentations. Strain measurements obtained from automatically estimated myocardial contours showed good to excellent agreement with manual pipelines, and remained within the limits of inter-user variability estimated in previous studies.ConclusionSpatio-temporal deep learning shows increased robustness for the segmentation of cine DENSE images. It provides excellent agreement with manual segmentation for strain extraction. Deep learning will facilitate the analysis of DENSE data, bringing it one step closer to clinical routine.
引用
收藏
页数:17
相关论文
共 64 条
[1]   DENSE: Displacement encoding with stimulated echoes in cardiac functional MRI [J].
Aletras, AH ;
Ding, SJ ;
Balaban, RS ;
Wen, H .
JOURNAL OF MAGNETIC RESONANCE, 1999, 137 (01) :247-252
[2]   Myocardial strain imaging: review of general principles, validation, and sources of discrepancies [J].
Amzulescu, M. S. ;
De Craene, M. ;
Langet, H. ;
Pasquet, A. ;
Vancraeynest, D. ;
Pouleur, A. C. ;
Vanoverschelde, J. L. ;
Gerber, B. L. .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 (06) :605-619
[3]   Reproducibility of global and segmental myocardial strain using cine DENSE at 3 T: a multicenter cardiovascular magnetic resonance study in healthy subjects and patients with heart disease [J].
Auger, Daniel A. ;
Ghadimi, Sona ;
Cai, Xiaoying ;
Reagan, Claire E. ;
Sun, Changyu ;
Abdi, Mohamad ;
Cao, Jie Jane ;
Cheng, Joshua Y. ;
Ngai, Nora ;
Scott, Andrew D. ;
Ferreira, Pedro F. ;
Oshinski, John N. ;
Emamifar, Nick ;
Ennis, Daniel B. ;
Loecher, Michael ;
Liu, Zhan-Qiu ;
Croisille, Pierre ;
Viallon, Magalie ;
Bilchick, Kenneth C. ;
Epstein, Frederick H. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2022, 24 (01)
[4]   Deep-learning cardiac motion analysis for human survival prediction [J].
Bello, Ghalib A. ;
Dawes, Timothy J. W. ;
Duan, Jinming ;
Biffi, Carlo ;
de Marvao, Antonio ;
Howard, Luke S. G. E. ;
Gibbs, J. Simon R. ;
Wilkins, Martin R. ;
Cook, Stuart A. ;
Rueckert, Daniel ;
O'Regan, Declan P. .
NATURE MACHINE INTELLIGENCE, 2019, 1 (02) :95-+
[5]  
BHF Health Intelligence Team, 2022, GLOB HEART CIRC DIS
[6]   Model-based segmentation using neural network-based boundary detectors: Application to prostate and heart segmentation in MR images [J].
Brosch, Tom ;
Peters, Jochen ;
Groth, Alexandra ;
Weber, Frank Michael ;
Weese, Jurgen .
MACHINE LEARNING WITH APPLICATIONS, 2021, 6
[7]  
Byrne N, 2022, Arxiv, DOI arXiv:2107.12689
[8]   Reproducibility of Speckle-Tracking-Based Strain Measures of Left Ventricular Function in a Community-Based Study [J].
Cheng, Susan ;
Larson, Martin G. ;
McCabe, Elizabeth L. ;
Osypiuk, Ewa ;
Lehman, Birgitta T. ;
Stanchev, Plamen ;
Aragam, Jayashri ;
Benjamin, Emelia J. ;
Solomon, Scott D. ;
Vasan, Ramachandran S. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (11) :1258-U160
[9]   Mechanics of the single left ventricle - A study in ventricuiar-ventricular interaction II [J].
Fogel, MA ;
Weinberg, PM ;
Gupta, KB ;
Rychik, J ;
Hubbard, A ;
Hoffman, EA ;
Haselgrove, J .
CIRCULATION, 1998, 98 (04) :330-338
[10]   Left ventricular strain and its pattern estimated from cine CMR and validation with DENSE [J].
Gao, Hao ;
Allan, Andrew ;
McComb, Christie ;
Luo, Xiaoyu ;
Berry, Colin .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (13) :3637-3656