Improvements in image quality after optimization in digital intraoral radiographs

被引:2
|
作者
Barrineau, Ashley B. [1 ]
Mah, Peter [2 ]
Mallya, Sanjay M. [3 ]
机构
[1] Univ Calif Los Angeles, Sch Dent, Sect Endodont, Los Angeles, CA USA
[2] Dent Imaging Consultants, Box 29214 Med Ctr Stn, San Antonio, TX 78229 USA
[3] Univ Calif Los Angeles, Sch Dent, Sect Maxillofacial Radiol, Los Angeles, CA USA
关键词
Quality control; quality assurance; image optimization; digital radiography; exposure optimization; radiographic phantom; image analysis; ASSURANCE; ACCURACY;
D O I
10.1016/j.adaj.2022.09.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background. Digital intraoral radiographic exposures are optimized largely on the basis of subjective assessment of diagnostic image quality. This study presents an objective approach to optimize radiographic exposure settings for digital intraoral radiographic systems.Methods. Seven size 2 digital intraoral systems were assessed for image quality and determination of optimal exposure following the protocol specified in American National Standard Institute/American Dental Association Standard No. 1094: Quality Assurance for Digital Intra-Oral Radiographic Systems. A ProX radiograph unit (Planmeca) at 63 kVp and 6 mA was used to obtain radiographs of the Dental Digital Quality Assurance phantom. ImageJ software (National Institutes of Health) was used to quantify dynamic range and spatial resolution, and contrast perceptibility was evaluated visually. Optimal exposure is the setting with the maximal contrast perceptibility and spatial resolution while displaying the full dynamic range. After image optimization, a custom phantom consisting of an endodontically prepared tooth was imaged to evaluate the file position relative to the apex for each system. Differences in distances between file position relative to the root apex at the optimal exposure as well as 1 increment above and below were measured.Results. Radiographic images obtained at the optimal exposure yielded better visualization and more accurate measurements of the file tip relative to the apex.Conclusions. Optimizing radiographic exposures improves image quality and accuracy in clinical decisions.Practical Implications. Improvement in image quality and better accuracy in actual distance of the endodontic file to the radiographic apex coupled with complete cleaning, shaping, and obturation of the canal should lead to better endodontic treatment outcomes.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 50 条
  • [1] Does image file transfer, exposure time and optimization algorithm affect digital intraoral radiographs?
    Grzebieluch, Wojciech
    Kaczmarek, Urszula
    Staniowski, Tomasz
    Mikulewicz, Marcin
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2020, 29 (12): : 1449 - 1458
  • [2] IMAGE QUALITY OF INTRAORAL RADIOGRAPHS USED BY GENERAL-PRACTITIONERS IN PROSTHODONTIC TREATMENT PLANNING
    SVENSON, B
    ERIKSSON, T
    KRONSTROM, M
    PALMQVIST, S
    DENTOMAXILLOFACIAL RADIOLOGY, 1994, 23 (01) : 46 - 48
  • [3] Quality Assurance Audit of Digital Intraoral Periapical Radiographs at the Undergraduate Dental Clinics
    Javed, Muhammad Qasim
    Kolarkodi, Shaul Hameed
    Riaz, Arham
    Nawabi, Shazia
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2020, 30 (12): : 1339 - 1342
  • [4] The effects of compression on the image quality of digital panoramic radiographs
    Yasar, Fusun
    Yesilova, Esra
    Apaydin, Burcu
    CLINICAL ORAL INVESTIGATIONS, 2012, 16 (03) : 719 - 726
  • [5] Current status on the application of image processing of digital intraoral radiographs amongst general dental practitioners
    Tohidast, Parisa
    Shi, Xie-Qi
    SWEDISH DENTAL JOURNAL, 2016, 40 (02) : 113 - 119
  • [6] Assessment of Image Quality in Digital Radiographs Submitted for Hip Dysplasia Screening
    Moorman, Lilah
    Precht, Helle
    Jensen, Janni
    Svalastoga, Eiliv
    Nielsen, Dorte H.
    Proschowsky, Helle F.
    McEvoy, Fintan J.
    FRONTIERS IN VETERINARY SCIENCE, 2019, 6
  • [7] Physical properties of a system for direct acquisition of digital intraoral radiographs
    Gang Li
    Kazumori Yoshiura
    Xie-Qi Shi
    Ulf Welander
    William D McDavid
    Oral Radiology, 2003, 19 (1) : 22 - 27
  • [8] IT-BASED EVALUATION AND AUTOMATIC IMPROVEMENT OF THE QUALITY OF INTRAORAL RADIOGRAPHS
    KOCH, S
    WAGNER, IV
    SEIPEL, S
    SCHNEIDER, W
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1995, 46 (01) : 41 - 50
  • [9] Influence of the incorporation of a lead foil to intraoral digital receptors on the image quality and root fracture diagnosis
    Gomes, Amanda Farias
    Nejaim, Yuri
    Fontenele, Rocharles Cavalcante
    Haiter-Neto, Francisco
    Freitas, Deborah Queiroz
    DENTOMAXILLOFACIAL RADIOLOGY, 2019, 48 (06)
  • [10] Relationship between image information content and observer performance in digital intraoral radiography
    Takarabe, Shinya
    Okamura, Kazutoshi
    Kuramoto, Taku
    Tokumori, Kenji
    Kato, Toyoyuki
    Yoshiura, Kazunori
    ORAL RADIOLOGY, 2023, 39 (03) : 491 - 503