Iterative reconstruction of low-dose CT based on differential sparse

被引:136
作者
Lu, Siyu [1 ]
Yang, Bo [1 ]
Xiao, Ye [1 ]
Liu, Shan [1 ]
Liu, Mingzhe [2 ]
Yin, Lirong [3 ]
Zheng, Wenfeng [1 ]
机构
[1] Univ Elect Sci & Technol China, Sch Automat, Chengdu 610054, Peoples R China
[2] Wenzhou Univ Technol, Sch Data Sci & Artificial Intelligence, Wenzhou 325000, Peoples R China
[3] Louisiana State Univ, Dept Geog & Anthropol, Baton Rouge, LA 70803 USA
关键词
Low dose CT; Sparse representation; Sparse transform; Iterative reconstruction; Image processing; IMAGE-RECONSTRUCTION; COMPUTED-TOMOGRAPHY;
D O I
10.1016/j.bspc.2022.104204
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The commonly used method to reduce the dose is to reduce the tube current. The number of photons received by the detector decreases, making the CT image obtained by analytical reconstruction full of speckle noise and strip artifacts. It interferes with the diagnosis and analysis of the disease. Therefore, how to reduce the radiation dose of CT and ensuring CT's imaging quality is an important research topic in the field of low-dose CT. This paper proposes a discriminative sparse transform iterative reconstruction algorithm inspired by the previous image compressed sensing reconstruction and the differential feature representation model. The global constraint term is used to constrain the consistency between the projected data to be reconstructed and the real projection data. The prior information constraint term constrains the reconstructed image close to the preceding image. This paper adds low-dose CT images obtained from image post-processing based on learning sparse transform to the prior information. Compared with the global constraints constructed only by learning sparse transform, the discriminative sparse transform constraints can effectively introduce a priori image and reconstruct a better image effect. Also, the improved algorithm's prior image avoids the dependence of the classical prior image compression sensing reconstruction and the differential feature representation model on the prior image and avoids the registration and matching problem of the reconstructed image caused by the difference of the prior image source.
引用
收藏
页数:11
相关论文
共 44 条
[1]  
Al M, 2014, Nahrain Univ. Coll. Eng. J., V17, P151
[2]   Low-dose CT Reconstruction Based on Multiscale Dictionary [J].
Bai, Ti ;
Mou, Xuanqin ;
Xu, Qiong ;
Zhang, Yanbo .
MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
[3]  
Bertasius G, 2015, PROC CVPR IEEE, P4380, DOI 10.1109/CVPR.2015.7299067
[4]   Time-Resolved Interventional Cardiac C-arm Cone-Beam CT: An Application of the PICCS Algorithm [J].
Chen, Guang-Hong ;
Theriault-Lauzier, Pascal ;
Tang, Jie ;
Nett, Brian ;
Leng, Shuai ;
Zambelli, Joseph ;
Qi, Zhihua ;
Bevins, Nicholas ;
Raval, Amish ;
Reeder, Scott ;
Rowley, Howard .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (04) :907-923
[5]   Low-dose CT via convolutional neural network [J].
Chen, Hu ;
Zhang, Yi ;
Zhang, Weihua ;
Liao, Peixi ;
Li, Ke ;
Zhou, Jiliu ;
Wang, Ge .
BIOMEDICAL OPTICS EXPRESS, 2017, 8 (02) :679-694
[6]   Artifact Suppressed Dictionary Learning for Low-Dose CT Image Processing [J].
Chen, Yang ;
Shi, Luyao ;
Feng, Qianjing ;
Yang, Jian ;
Shu, Huazhong ;
Luo, Limin ;
Coatrieux, Jean-Louis ;
Chen, Wufan .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (12) :2271-2292
[7]   Thoracic low-dose CT image processing using an artifact suppressed large-scale nonlocal means [J].
Chen, Yang ;
Yang, Zhou ;
Hu, Yining ;
Yang, Guanyu ;
Zhu, Yongcheng ;
Li, Yinsheng ;
Luo, Limin ;
Chen, Wufan ;
Toumoulin, Christine .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (09) :2667-2688
[8]   Regularization Designs for Uniform Spatial Resolution and Noise Properties in Statistical Image Reconstruction for 3-D X-ray CT [J].
Cho, Jang Hwan ;
Fessler, Jeffrey A. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) :678-689
[9]   Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients [J].
Frush, DP ;
Slack, CC ;
Hollingsworth, CL ;
Bisset, GS ;
Donnelly, LF ;
Hsieh, J ;
Lavin-Wensell, T ;
Mayo, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) :1107-1113
[10]   Power frequency estimation using sine filtering of optimal initial phase [J].
Guo, Fupei ;
Yang, Bo ;
Zheng, Wenfeng ;
Liu, Shan .
MEASUREMENT, 2021, 186