Diagnostic performance of wide-field optical coherence tomography angiography in detecting open-angle glaucoma in high myopia

被引:3
|
作者
Zhang, Yinhang [1 ]
Wang, Deming [1 ]
Lin, Fengbin [1 ]
Song, Yunhe [1 ]
Chen, Yu [1 ]
Peng, Yuying [1 ]
Chen, Meiling [1 ]
Liu, Yuhong [1 ]
Jiang, Jiaxuan [1 ]
Yang, Zefeng [1 ]
Li, Fei [1 ,2 ]
Zhang, Xiulan [1 ,2 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, Guangdong Prov Clin Res Ctr Ocular Dis, State Key Lab Ophthalmol,Guangdong Prov Key Lab O, Guangzhou, Peoples R China
[2] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, Guangdong Prov Clin Res Ctr Ocular Dis, State Key Lab Ophthalmol,Guangdong Prov Key Lab O, Guangzhou 510060, Peoples R China
基金
中国国家自然科学基金;
关键词
capillary density; diagnostic performance; high myopia; open-angle glaucoma; optical coherence tomography angiography; wide-field; VISUAL-FIELD; EYES; CLASSIFICATION; PARAMETERS; ACCURACY; DEFECTS; IMAGES; MAP;
D O I
10.1111/aos.16603
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the diagnostic performance of the capillary density (CD) of the central 1-6 mm and peripheral 6-12 mm annular regions in detecting open-angle glaucoma in high myopia (HM) using 15 x 12 mm wide-field swept-source optical coherence tomography angiography (WF SS-OCTA).Methods: The study enrolled 206 and 103 eyes with HM and highly myopic open-angle glaucoma (HM-OAG), respectively. WF SS-OCTA images centred on the fovea were obtained to analyse the changes in the CD in the 1-3 mm, 3-6 mm, 6-9 mm, and 9-12 mm annular regions. CD of the superficial capillary plexus (SCP) was measured with the built-in software. The area under the receiver operating characteristic curve (AUROC) of each region was compared.Results: The diagnostic performance of the SCP CD in the central 1-6 mm annular region (AUROC = 0.849) was better than that in the peripheral 6-12 mm annular region (AUROC = 0.756, p = 0.001). The annular AUROCs of SCP CD peaked in the 3-6 mm annular region (AUROC = 0.858) and gradually decreased with increasing diameter and were lower than the corresponding AUROCs of the ganglion cell-inner plexiform layer thickness (p < 0.05 for all comparisons). SCP CD of the inferior quadrant in the 3-6 mm annular region had the best diagnostic performance (AUROC = 0.859).Conclusion: The SCP CD in the central 1-6 mm annular region exhibited better diagnostic performance for the detection of HM-OAG in HM. The assessment of more peripheral regions has no added value in detecting glaucoma in HM.
引用
收藏
页码:E168 / E177
页数:10
相关论文
共 50 条
  • [41] Wide-field optical coherence tomography angiography for the detection of proliferative diabetic retinopathy
    Pichi, Francesco
    Smith, Scott D.
    Abboud, Emad B.
    Neri, Piergiorgio
    Woodstock, Elizabeth
    Hay, Steven
    Levine, Emily
    Baumal, Caroline R.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (09) : 1901 - 1909
  • [42] Clinical Utilisation of Wide-Field Optical Coherence Tomography and Angiography: A Narrative Review
    Nissen, Anne Helene K.
    Vergmann, Anna Stage
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (04) : 903 - 915
  • [43] Wide-field optical coherence tomography-angiography in familial exudative vitreoretinopathy
    Gupta, C.
    Kumar, S.
    Shroff, D.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2024, 47 (07):
  • [44] Clinical Utilisation of Wide-Field Optical Coherence Tomography and Angiography: A Narrative Review
    Anne Helene K. Nissen
    Anna Stage Vergmann
    Ophthalmology and Therapy, 2024, 13 : 903 - 915
  • [45] Diagnostic Consistency and Relation Between Optical Coherence Tomography and Standard Automated Perimetry in Primary Open-Angle Glaucoma
    Toprak, Ibrahim
    Yaylali, Volkan
    Yildirim, Cem
    SEMINARS IN OPHTHALMOLOGY, 2017, 32 (02) : 185 - 190
  • [46] A comparison of two optical coherence tomography-angiography devices in pseudoexfoliation glaucoma versus primary open-angle glaucoma and healthy subjects
    Rebolleda, Gema
    Perez-Sarriegui, Ane
    De Juan, Victoria
    Ortiz-Toquero, Sara
    Munoz-Negrete, Francisco J.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2019, 29 (06) : 636 - 644
  • [47] Comparison of Retinal Microvasculature in Patients With Alzheimer's Disease and Primary Open-Angle Glaucoma by Optical Coherence Tomography Angiography
    Zabel, Przemyslaw
    Kaluzny, Jakub J.
    Wilkosc-Debczynska, Monika
    Gebska-Toloczko, Martyna
    Suwala, Karolina
    Zabel, Katarzyna
    Zaron, Agata
    Kucharski, Robert
    Araszkiewicz, Aleksander
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (10) : 3447 - 3455
  • [48] Relationship between N95 Amplitude of Pattern Electroretinogram and Optical Coherence Tomography Angiography in Open-Angle Glaucoma
    Lee, Taekjune
    Seo, Du Ri
    Kim, Joo Yeon
    Choi, Wungrak
    Lee, Sang Yeop
    Lee, Jun Mo
    Seong, Gong Je
    Kim, Chan Yun
    Bae, Won Hyoung
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (12) : 1 - 13
  • [49] Comparison of peripapillary vascular density as measured by optical coherence tomography angiography between various types of open-angle glaucoma
    Simsek, M.
    Oral, Y.
    Inan, S.
    Akdogan, M.
    Sabaner, M. Cem
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (09): : 1047 - 1054
  • [50] Effect of high myopia on glaucoma diagnostic parameters measured with optical coherence tomography
    Kita, Yoshiyuki
    Kita, Ritsuko
    Takeyama, Asuka
    Tomita, Goji
    Goldberg, Ivan
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (08): : 722 - 728