Diagnostic performance of wide-field optical coherence tomography angiography in detecting open-angle glaucoma in high myopia

被引:3
|
作者
Zhang, Yinhang [1 ]
Wang, Deming [1 ]
Lin, Fengbin [1 ]
Song, Yunhe [1 ]
Chen, Yu [1 ]
Peng, Yuying [1 ]
Chen, Meiling [1 ]
Liu, Yuhong [1 ]
Jiang, Jiaxuan [1 ]
Yang, Zefeng [1 ]
Li, Fei [1 ,2 ]
Zhang, Xiulan [1 ,2 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, Guangdong Prov Clin Res Ctr Ocular Dis, State Key Lab Ophthalmol,Guangdong Prov Key Lab O, Guangzhou, Peoples R China
[2] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, Guangdong Prov Clin Res Ctr Ocular Dis, State Key Lab Ophthalmol,Guangdong Prov Key Lab O, Guangzhou 510060, Peoples R China
基金
中国国家自然科学基金;
关键词
capillary density; diagnostic performance; high myopia; open-angle glaucoma; optical coherence tomography angiography; wide-field; VISUAL-FIELD; EYES; CLASSIFICATION; PARAMETERS; ACCURACY; DEFECTS; IMAGES; MAP;
D O I
10.1111/aos.16603
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the diagnostic performance of the capillary density (CD) of the central 1-6 mm and peripheral 6-12 mm annular regions in detecting open-angle glaucoma in high myopia (HM) using 15 x 12 mm wide-field swept-source optical coherence tomography angiography (WF SS-OCTA).Methods: The study enrolled 206 and 103 eyes with HM and highly myopic open-angle glaucoma (HM-OAG), respectively. WF SS-OCTA images centred on the fovea were obtained to analyse the changes in the CD in the 1-3 mm, 3-6 mm, 6-9 mm, and 9-12 mm annular regions. CD of the superficial capillary plexus (SCP) was measured with the built-in software. The area under the receiver operating characteristic curve (AUROC) of each region was compared.Results: The diagnostic performance of the SCP CD in the central 1-6 mm annular region (AUROC = 0.849) was better than that in the peripheral 6-12 mm annular region (AUROC = 0.756, p = 0.001). The annular AUROCs of SCP CD peaked in the 3-6 mm annular region (AUROC = 0.858) and gradually decreased with increasing diameter and were lower than the corresponding AUROCs of the ganglion cell-inner plexiform layer thickness (p < 0.05 for all comparisons). SCP CD of the inferior quadrant in the 3-6 mm annular region had the best diagnostic performance (AUROC = 0.859).Conclusion: The SCP CD in the central 1-6 mm annular region exhibited better diagnostic performance for the detection of HM-OAG in HM. The assessment of more peripheral regions has no added value in detecting glaucoma in HM.
引用
收藏
页码:E168 / E177
页数:10
相关论文
共 50 条
  • [21] Retinal Microcirculatory Responses to Hyperoxia in Primary Open-Angle Glaucoma Using Optical Coherence Tomography Angiography
    Fan, Xintong
    Xu, Huan
    Zhai, Ruyi
    Sheng, Qilian
    Kong, Xiangmei
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (14)
  • [22] HIGH MYOPIA AND PRIMARY OPEN-ANGLE GLAUCOMA
    PODOS, SM
    BECKER, B
    MORTON, WR
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1966, 62 (06) : 1039 - &
  • [23] Optical Coherence Tomography Angiography of Optic Disc in Eyes With Primary Open-angle Glaucoma and Normal-tension Glaucoma
    Toshev, Anani P.
    Schuster, Alexander Karl-Georg
    ul Hassan, Shahzada N.
    Pfeiffer, Norbert
    Hoffmann, Esther M.
    JOURNAL OF GLAUCOMA, 2019, 28 (03) : 243 - 251
  • [24] Diagnosis of Glaucoma Based on Few-Shot Learning with Wide-Field Optical Coherence Tomography Angiography
    Yang, Kyoung Ok
    Lee, Jung Min
    Shin, Younji
    Yoon, In Young
    Choi, Jun Won
    Lee, Won June
    BIOMEDICINES, 2024, 12 (04)
  • [25] Repeatability of Wide-field Optical Coherence Tomography Angiography in Normal Retina
    Eastline, Michael
    Munk, Marion R.
    Wolf, Sebastian
    Schaal, Karen B.
    Ebneter, Andreas
    Tian, Meng
    Giannakaki-Zimmermann, Helena
    Zinkernagel, Martin S.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2019, 8 (03):
  • [26] Peripapillary and Macular Vessel Density Measurement by Optical Coherence Tomography Angiography in Pseudoexfoliation and Primary Open-angle Glaucoma
    Jo, Youn Hye
    Sung, Kyung Rim
    Shin, Joong Won
    JOURNAL OF GLAUCOMA, 2020, 29 (05) : 381 - 385
  • [27] Retinal nerve fiber layer in primary open-angle glaucoma with high myopia determined by optical coherence tomography and scanning laser polarimetry
    Wang Xiao-en
    Wang Xiao-yu
    Gu Yang-shun
    Huang Zhu
    CHINESE MEDICAL JOURNAL, 2013, 126 (08) : 1425 - 1429
  • [28] Correlation of retinal sensitivity in microperimetry with vascular density in optical coherence tomography angiography in primary open-angle glaucoma
    Zabel, Katarzyna
    Zabel, Przemyslaw
    Kaluzna, Martyna
    Lamkowski, Aleksander
    Jaworski, Damian
    Wietlicka-Piszcz, Magdalena
    Kaluzny, Jakub J.
    PLOS ONE, 2020, 15 (07):
  • [29] Anterior Segment Optical Coherence Tomography Angiography Imaging of Conjunctiva and Intrasclera in Treated Primary Open-Angle Glaucoma
    Akagi, Tadamichi
    Uji, Akihito
    Okamoto, Yoko
    Suda, Kenji
    Kameda, Takanori
    Nakanishi, Hideo
    Ikeda, Hanako Ohashi
    Miyake, Masahiro
    Nakano, Eri
    Motozawa, Naohiro
    Tsujikawa, Akitaka
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 208 : 313 - 322
  • [30] Retinal nerve fiber layer in primary open-angle glaucoma with high myopia determined by optical coherence tomography and scanning laser polarimetry
    WANG Xiao-en
    WANG Xiao-yu
    GU Yang-shun
    HUANG Zhu
    中华医学杂志(英文版), 2013, (08) : 1425 - 1429