Diagnostic performance of wide-field optical coherence tomography angiography in detecting open-angle glaucoma in high myopia

被引:3
|
作者
Zhang, Yinhang [1 ]
Wang, Deming [1 ]
Lin, Fengbin [1 ]
Song, Yunhe [1 ]
Chen, Yu [1 ]
Peng, Yuying [1 ]
Chen, Meiling [1 ]
Liu, Yuhong [1 ]
Jiang, Jiaxuan [1 ]
Yang, Zefeng [1 ]
Li, Fei [1 ,2 ]
Zhang, Xiulan [1 ,2 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, Guangdong Prov Clin Res Ctr Ocular Dis, State Key Lab Ophthalmol,Guangdong Prov Key Lab O, Guangzhou, Peoples R China
[2] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, Guangdong Prov Clin Res Ctr Ocular Dis, State Key Lab Ophthalmol,Guangdong Prov Key Lab O, Guangzhou 510060, Peoples R China
基金
中国国家自然科学基金;
关键词
capillary density; diagnostic performance; high myopia; open-angle glaucoma; optical coherence tomography angiography; wide-field; VISUAL-FIELD; EYES; CLASSIFICATION; PARAMETERS; ACCURACY; DEFECTS; IMAGES; MAP;
D O I
10.1111/aos.16603
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the diagnostic performance of the capillary density (CD) of the central 1-6 mm and peripheral 6-12 mm annular regions in detecting open-angle glaucoma in high myopia (HM) using 15 x 12 mm wide-field swept-source optical coherence tomography angiography (WF SS-OCTA).Methods: The study enrolled 206 and 103 eyes with HM and highly myopic open-angle glaucoma (HM-OAG), respectively. WF SS-OCTA images centred on the fovea were obtained to analyse the changes in the CD in the 1-3 mm, 3-6 mm, 6-9 mm, and 9-12 mm annular regions. CD of the superficial capillary plexus (SCP) was measured with the built-in software. The area under the receiver operating characteristic curve (AUROC) of each region was compared.Results: The diagnostic performance of the SCP CD in the central 1-6 mm annular region (AUROC = 0.849) was better than that in the peripheral 6-12 mm annular region (AUROC = 0.756, p = 0.001). The annular AUROCs of SCP CD peaked in the 3-6 mm annular region (AUROC = 0.858) and gradually decreased with increasing diameter and were lower than the corresponding AUROCs of the ganglion cell-inner plexiform layer thickness (p < 0.05 for all comparisons). SCP CD of the inferior quadrant in the 3-6 mm annular region had the best diagnostic performance (AUROC = 0.859).Conclusion: The SCP CD in the central 1-6 mm annular region exhibited better diagnostic performance for the detection of HM-OAG in HM. The assessment of more peripheral regions has no added value in detecting glaucoma in HM.