Comparative study of the effects of conventional shot peening and ultrasonic shot peening on very high cycle fatigue properties of GH4169 superalloy

被引:26
作者
Qin, Zhi [1 ]
Li, Bin [1 ]
Chen, Tianyue [1 ]
Chen, Chen [1 ]
Chen, Rui [1 ]
Ma, Hongchang [1 ]
Xue, Hongqian [1 ]
Yao, Changfeng [1 ]
Tan, Liang [1 ]
机构
[1] Northwestern Polytech Univ, Key Lab High Performance Mfg Aero Engine, Minist Ind & Informat Technol, Xian 710072, Peoples R China
基金
中国国家自然科学基金;
关键词
Conventional shot peening; Ultrasonic shot peening; Very high cycle fatigue; Stress triaxiality; GH4169; superalloy; HIGH-STRENGTH STEELS; CRACK INITIATION; TRAPPING SITES; MICROSTRUCTURE; INCLUSION; BEHAVIOR;
D O I
10.1016/j.ijfatigue.2023.107799
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This study investigates the effects of two different shot peening techniques, conventional shot peening (CSP) and ultrasonic shot peening (USP), on the very high cycle fatigue (VHCF) properties of the GH4169 superalloy. The study evaluates and compares surface roughness, X-ray diffraction patterns, microhardness, and residual stress in specimens treated with CSP and USP. The VHCF tests reveal that both CSP and USP treatments improve the VHCF properties of the GH4169 superalloy. However, while the USP-treated specimens have deeper work hardening and compress residual stress layers, their VHCF lives are significantly shorter than those of the CSP-treated specimens. Additionally, the study finds that the stress triaxiality, which inhibits dislocations at the crack tip, is higher closer to the center of the specimen. The transmission electron microscopy (TEM) results further confirm that the reduced dislocation density and increased stress concentration in the plastic zone of the high stress triaxiality region promote fatigue short crack propagation and reduce the fatigue properties of the material.
引用
收藏
页数:14
相关论文
共 38 条
  • [1] Effect of ultrasonic shot peening duration on microstructure, corrosion behavior and cell response of cp-Ti
    Agrawal, Rahul Kumar
    Pandey, Vaibhav
    Barhanpurkar-Naik, Amruta
    Wani, Mohan R.
    Chattopadhyay, Kausik
    Singh, Vakil
    [J]. ULTRASONICS, 2020, 104
  • [2] In-situ SEM study of fatigue crack growth behaviour in IN718
    Andersson, H
    Persson, C
    [J]. INTERNATIONAL JOURNAL OF FATIGUE, 2004, 26 (03) : 211 - 219
  • [3] Statistical analysis of high cycle fatigue life and inclusion size distribution in shot peened 300M steel
    Bag, Amrita
    Delbergue, Dorian
    Bocher, Philippe
    Levesque, Martin
    Brochu, Myriam
    [J]. INTERNATIONAL JOURNAL OF FATIGUE, 2019, 118 : 126 - 138
  • [4] Bridgman P.W., 1964, Studies in large plastic flow and fracture
  • [5] Broek D., 2012, Elementary engineering fracture mechanics
  • [6] Effects of ultrasonic shot peening process parameters on nanocrystalline and mechanical properties of pure copper surface
    Chen, Hu
    Guan, Yanjin
    Zhu, Lihua
    Li, Yi
    Zhai, Jiqiang
    Lin, Jun
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 2021, 259
  • [7] Donachie M. J., 2002, Superalloys: A Technical Guide
  • [8] Effect of surface mechanical attrition treatment on high cycle and very high cycle fatigue of a 7075-T6 aluminium alloy
    Gao, Tao
    Sun, Zhidan
    Xue, Hongqian
    Retraint, Delphine
    [J]. INTERNATIONAL JOURNAL OF FATIGUE, 2020, 139
  • [9] An analysis of residual stress fields caused by shot peening
    Gao, YK
    Yao, M
    Li, JK
    [J]. METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2002, 33 (06): : 1775 - 1778
  • [10] Effects of Hot Corrosion on Fatigue Performance of GH4169 Alloy
    Jiang, R.
    Zhang, L. C.
    Zhao, Y.
    Chen, X. H.
    Gan, B.
    Hao, X. C.
    Song, Y. D.
    [J]. JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2021, 30 (03) : 2300 - 2308