Sensitivity analysis of optical scatterometry technique for high aspect ratio trench measurement

被引:1
|
作者
Grasland, J. [1 ,2 ]
Le Cunff, D. [1 ]
Pham, H. L. [2 ]
Besacier, M. [2 ]
Tortai, J. H. [2 ]
机构
[1] STMicroelectronics, 850 Rue Jean Monnet, F-38926 Crolles, France
[2] Univ Grenoble Alpes, CNRS, CEA LETI Minatec, Grenoble INP Inst Engn & Management Univ Grenoble, F-38054 Grenoble, France
来源
METROLOGY, INSPECTION, AND PROCESS CONTROL XXXVII | 2023年 / 12496卷
关键词
metrology; trenches; OCD; RCWA; sensitivity analysis; Sobol index; Mueller matrix; COUPLED-WAVE ANALYSIS; EFFICIENT IMPLEMENTATION; ELLIPSOMETRY;
D O I
10.1117/12.2657876
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For CMOS image sensors fabrication, deep trenches are commonly incorporated in the device to isolate the individual pixel one another within the pixel matrix. These etched structures typically exhibit a high aspect ratio of 1:20 and controlling such narrow and deep object is a challenge for inline metrology. In a manufacturing environment, the preferred method for trench height measurements remains the optical scatterometry (OCD) technique as being very sensitive and reliable. Still, it requires time and resources for model construction and validation. It appears then that an analysis of its predicted sensitivity could be a valuable pre-step before starting any activity on large periodical objects where OCD sensitivity can reach its limits. In this study, we tested this approach for deep trench structures with CD dimension in the range of 100nm to 1400nm and the depth from 100 nm to 5 mu m. The periodicity (pitch) was fixed at CD*2. At first, 3D Mueller scatterometry signatures were modelled selecting spectroscopic ellipsometry acquisition configurations according to industrial most common ones. Thanks to an optimized RCWA (Rigorous Coupled Wave Analysis) code developed inhouse, calculation durations were reduced enough to allow massive data generation. By implementing a sensitivity analysis approach that uses Sobol coefficients, the sensitivity of the OCD metrology technique is here evaluated for each CD and depth values. More particulary, it will be illustrated by a CD range of.10% of 350nm and with the depth of the trench varying from 100nm up to 5 mu m. As a results, a sensitivity frontier can be estimated at around 3 mu m, a critical depth value above which OCD in the given configuration is no more sensitive to the metrics determination. Such observation will be further discussed by analysis of convergence evaluation.
引用
收藏
页数:12
相关论文
共 31 条
  • [1] Determination of an optimal measurement configuration in optical scatterometry using global sensitivity analysis
    Dong, Zhengqiong
    Liu, Shiyuan
    Chen, Xiuguo
    Zhang, Chuanwei
    THIN SOLID FILMS, 2014, 562 : 16 - 23
  • [2] Optimization of measurement configuration in optical scatterometry for one-dimensional nanostructures based on sensitivity analysis
    Dong Zheng-Qiong
    Liu Shi-Yuan
    Chen Xiu-Guo
    Shi Ya-Ting
    Zhang Chuan-Wei
    Jiang Hao
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2016, 35 (01) : 116 - 122
  • [3] Optimization of measurement configuration in optical scatterometry for one-dimensional nanostructures based on sensitivity analysis
    Dong Z.-Q.
    Liu S.-Y.
    Chen X.-G.
    Shi Y.-T.
    Zhang C.-W.
    Jiang H.
    Chen, Xiu-Guo (xiuguochen@hust.edu.cn), 2016, Chinese Optical Society (35): : 116 - 122
  • [4] Optical imaging and image analysis for high aspect ratio NEMS
    Syms, R. R. A.
    Bouchaala, A.
    Sydoruk, O.
    Liu, D.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2019, 29 (01)
  • [5] Non-integral model-based scatterometry for CD metrology of single high-aspect-ratio microstructures
    Chein, Wei-Hsin
    Yang, Fu-Sheng
    Fu, Zi-Ying
    Chen, Liang-Chia
    SURFACE TOPOGRAPHY-METROLOGY AND PROPERTIES, 2023, 11 (02)
  • [6] Optical Detection Method for High Aspect Ratio Microstructures
    Wei, Wenbin
    Hou, Shuangyue
    Wu, Zhao
    Hu, Yue
    Wang, Yi
    Chen, Lijuan
    Xiong, Ying
    Tian, Yangchao
    Liu, Gang
    MICROMACHINES, 2020, 11 (03)
  • [7] In-line Metrology of High Aspect Ratio Structures with MBIR Technique
    Le Cunff, Delphine
    Hoeglund, Leif Jonny
    Laurent, Nicolas
    2011 22ND ANNUAL IEEE/SEMI ADVANCED SEMICONDUCTOR MANUFACTURING CONFERENCE (ASMC), 2011,
  • [8] Profile and surface measurement tool for high aspect-ratio microstructures
    Pourciel, JB
    Jalabert, L
    Masuzawa, T
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 2003, 46 (03) : 916 - 922
  • [9] Large Range Atomic Force Microscopy with High Aspect Ratio Micropipette Probe for Deep Trench Imaging
    Shi, Huiyao
    Wang, Kaixuan
    Tang, Si
    Zhai, Shenghang
    Shi, Jialin
    Su, Chanmin
    Liu, Lianqing
    SMALL METHODS, 2023, 7 (07)
  • [10] Microsystem for vertical profile measurement of high aspect-ratio microstructures
    Lebrasseur, E
    Pourciel, JB
    Bourouina, T
    Ozaki, M
    Masuzawa, T
    Fujita, H
    TRANSDUCERS '01: EUROSENSORS XV, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2001, : 1058 - 1061