Continuous versus Pulsatile Flow in 24-h Vascularized Composite Allograft Machine Perfusion in Swine: A Pilot Study

被引:8
作者
Tawa, Pierre [1 ,2 ,3 ,4 ]
Goutard, Marion [1 ,2 ,3 ,4 ]
Andrews, Alec R. [1 ,2 ,3 ]
Vries, Reinier J. de [2 ,3 ,5 ]
Rosales, Ivy A. [2 ,6 ]
Yeh, Heidi [2 ,7 ]
Uygun, Basak [2 ,3 ,8 ]
Randolph, Mark A. [1 ,2 ,3 ]
Lellouch, Alexandre G. [1 ,2 ,3 ,4 ]
Uygun, Korkut [1 ,2 ,3 ,8 ,10 ]
Cetrulo, Curtis L., Jr. [9 ]
机构
[1] Massachusetts Gen Hosp, Div Plast Surg, Boston, MA USA
[2] Harvard Med Sch, Boston, MA USA
[3] Shriners Hosp Children, Boston, MA USA
[4] Univ Paris 05, Hop Europe Georges Pompidou, Assistance Publ Hop Paris APHP, Serv Chirurg Plast, Paris, France
[5] Amsterdam Univ Med Centerse Locat AMC, Univ Amsterdam, Dept Surg, Amsterdam, Netherlands
[6] Massachusetts Gen Hosp, Ctr Transplantat Sci, Immunopathol Res Lab, Boston, MA USA
[7] Massachusetts Gen Hosp, Dept Surg, Boston, MA USA
[8] Massachusetts Gen Hosp, Ctr Engn Med & Surg, Boston, MA USA
[9] Massachusetts Gen Hosp, Harvard Med Sch, Dept Surg, Div Plast Surg, 55 Fruit St, Boston, MA 02114 USA
[10] Massachusetts Gen Hosp, Ctr Engn Med & Surg, Harvard Med Sch, Dept Surg, 51 Blossom St, Boston, MA 02114 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Swine; Machine perfusion; Preservation; Pulsatile flow; Subnormothermic; Vascularized composite allotransplantation; EX-SITU PERFUSION; PORCINE KIDNEY GRAFTS; ACELLULAR SOLUTION; TISSUE ALLOGRAFT; LIMB PERFUSION; PRESERVATION; TRANSPLANT; SURVIVAL; LUNG;
D O I
10.1016/j.jss.2022.11.003
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Multiple perfusion systems have been investigated on vascularized composite allografts, with various temperatures and different preservation solutions, most using continuous flow (CF). However, physiological flow is pulsatile and provides better outcomes in kidney and lung ex vivo perfusions. The objective of this pilot study is to compare pulsatile flow (PF) with CF in our 24-h subnormothermic machine perfusion protocol for swine hindlimbs. Methods: Partial hindlimbs were harvested from Yorkshire pigs and perfused with a modified Steen solution at 21 degrees C for 24 h either with CF (n = 3) or with pulsatile flow (PF) at 60 beats/min (n = 3). Perfusion parameters, endothelial markers, and muscle biopsies were assessed at different timepoints.Results: Overall, lactate levels were significantly lower in the PF group (P = 0.001). Glucose uptake and potassium concentration were similar in both groups throughout perfusion. Total nitric oxide levels were significantly higher in the PF group throughout perfusion (P = 0.032). Nitric oxide/endothelin-1 ratio also tends to be higher in the PF group, reflecting a potentially better vasoconductivity with PF, although not reaching statistical significance (P = 0.095). Arterial resistances were higher in the PF group (P < 0.001). Histological assessment did not show significant difference in muscular injury between the two groups. Weight increased quicker in the CF group but reached similar values with the PF after 24 h.Conclusions: This pilot study suggests that PF may provide superior preservation of vascu-larized composite allografts when perfused for 24 h at subnormothermic temperatures, with potential improvement in endothelial function and decreased ischemic injury. 2022 Elsevier Inc. All rights reserved.
引用
收藏
页码:1145 / 1153
页数:9
相关论文
共 29 条
  • [1] Randomized preclinical study of machine perfusion in vascularized composite allografts
    Amin, K. R.
    Stone, J. P.
    Kerr, J.
    Geraghty, A.
    Joseph, L.
    Montero-Fernandez, A.
    Wong, J. K.
    Fildes, J. E.
    [J]. BRITISH JOURNAL OF SURGERY, 2021, 108 (05) : 574 - 582
  • [2] PRINCIPLES OF SOLID-ORGAN PRESERVATION BY COLD-STORAGE
    BELZER, FO
    SOUTHARD, JH
    [J]. TRANSPLANTATION, 1988, 45 (04) : 673 - 676
  • [3] The pathophysiology of skeletal muscle ischemia and the reperfusion syndrome: a review
    Blaisdell, FW
    [J]. CARDIOVASCULAR SURGERY, 2002, 10 (06): : 620 - 630
  • [4] Comparison of pulsatile and nonpulsatile perfusion of the lung in an extracorporeal large animal model
    Brandes, H
    Albes, JM
    Conzelmann, A
    Wehrmann, M
    Ziemer, G
    [J]. EUROPEAN SURGICAL RESEARCH, 2002, 34 (04) : 321 - 329
  • [5] Prolonged fluid shear stress induces a distinct set of endothelial cell genes, most specifically lung Kruppel-like factor (KLF2)
    Dekker, RJ
    van Soest, S
    Fontijn, RD
    Salamanca, S
    de Groot, PG
    VanBavel, E
    Pannekoek, H
    Horrevoets, AJG
    [J]. BLOOD, 2002, 100 (05) : 1689 - 1698
  • [6] DOMINGOPECH J, 1991, INT ORTHOP, V15, P289
  • [7] Human hand allograft: report on first 6 months
    Dubernard, JM
    Owen, E
    Herzberg, G
    Lanzetta, M
    Martin, X
    Kapila, H
    Dawahra, M
    Hakim, NS
    [J]. LANCET, 1999, 353 (9161) : 1315 - 1320
  • [8] Role of Pulsatility in Hypothermic Reconditioning of Porcine Kidney Grafts by Machine Perfusion After Cold Storage
    Gallinat, Anja
    Fox, Mario
    Lueer, Bastian
    Efferz, Patrik
    Paul, Andreas
    Minor, Thomas
    [J]. TRANSPLANTATION, 2013, 96 (06) : 538 - 542
  • [9] Hypothermic Reconditioning of Porcine Kidney Grafts by Short-Term Preimplantation Machine Perfusion
    Gallinat, Anja
    Paul, Andreas
    Efferz, Patrik
    Lueer, Bastian
    Kaiser, Gernot
    Wohlschlaeger, Jeremias
    Treckmann, Juergen
    Minor, Thomas
    [J]. TRANSPLANTATION, 2012, 93 (08) : 787 - 793
  • [10] Govshievich A, 2021, PLAST RECONSTR SURG, V147, P1177, DOI 10.1097/PRS.0000000000007890