An enzyme-free electrochemical immunosensor based on MOF/SWCN nanocomposites for rapid and sensitive detection of fibroblast growth factor 21

被引:1
|
作者
Yu, Tianxiao [1 ]
Hou, Shikuan [2 ]
Fan, Xizhenzi [1 ]
Qiao, Yanxia [3 ]
Zhang, Guohua [4 ]
Wang, Lingli [1 ]
Ge, Jun [1 ]
机构
[1] Hebei Med Univ, Affiliated Obstet & Gynecol Hosp, Hosp Shijiazhuang 4, Res Ctr Clin Med Sci, Shijiazhuang 050000, Hebei, Peoples R China
[2] Hebei Med Univ, Affiliated Obstet & Gynecol Hosp, Hosp Shijiazhuang 4, Dept Clin Lab, Shijiazhuang 050000, Hebei, Peoples R China
[3] Hebei Med Univ, Affiliated Obstet & Gynecol Hosp, Hosp Shijiazhuang 4, Dept Neonatol, Shijiazhuang 050000, Hebei, Peoples R China
[4] Hebei Med Univ, Affiliated Obstet & Gynecol Hosp, Hosp Shijiazhuang 4, Dept Obstet & Gynecol, Shijiazhuang 050000, Hebei, Peoples R China
来源
关键词
Electrochemical immunosensor; MOF/SWCN; Staphylococcal protein A; Fibroblast growth factor 21; ORIENTED IMMOBILIZATION; SIGNAL AMPLIFICATION; PROTEIN-A; DEGRADATION; BIOMARKER; BINDING;
D O I
10.20964/2022.09.57
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this work, an enzyme-free electrochemical immunosensor based on metal-organic framework (MOF) and single-wall carbon nanotube (SWCN) nanocomposite coated glassy carbon electrode (GCE) for rapid and sensitive detection of fibroblast growth factor 21 (FGF-21) was proposed. The synthesized MOF/SWCN were characterized by transmission electron microscopy (TEM). It exhibited high-speed charge mobility, excellent conductivity and high surface area, significantly amplifying the current signal response. Furthermore, to immobilize the FGF-21 capture antibody on the MOF/SWCN electrode surface in an ordered orientation, staphylococcal protein A (SPA) was introduced as a connecting element, which significantly increased the antigen-binding ability and immunosensor stability. Under optimal conditions, the wide linear range of the immunosensor was 1.00 pg mL(-1) to 500 ng mL(-1), with a low detection limit was 0.35 pg mL(-1). Additionally, the immunosensor also showed excellent reproducibility and selectivity. It was also successfully used to detect FGF-21 in human serum samples with satisfying recoveries. Thus, the strategy provides a simple and sensitive method for FGF-21 detection, indicating significant potential applications in clinical diagnostics.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] An electrochemical sensor based on enzyme-free recycling amplification for sensitive and specific detection of miRNAs from cancer cells
    Jiang, Lili
    Yang, Yuling
    Lin, Yuhong
    Chen, Ziyi
    Xing, Chao
    Lu, Chunhua
    Yang, Huanghao
    Zhang, Shusheng
    ANALYST, 2020, 145 (09) : 3353 - 3358
  • [22] Enzyme-free electrochemical biosensor based on bio-barcode amplification for ultra-sensitive detection of microRNA
    Huai Xi
    Xiaolin Liang
    Guidan Huang
    Jinhua Liang
    Dandan Li
    Qilin Wen
    Yun Zhang
    Xiaofen Xiao
    Wenyuan Zhu
    Analytical Sciences, 2024, 40 : 285 - 290
  • [23] Enzyme-free electrochemical biosensor based on bio-barcode amplification for ultra-sensitive detection of microRNA
    Xi, Huai
    Liang, Xiaolin
    Huang, Guidan
    Liang, Jinhua
    Li, Dandan
    Wen, Qilin
    Zhang, Yun
    Xiao, Xiaofen
    Zhu, Wenyuan
    ANALYTICAL SCIENCES, 2024, 40 (02) : 285 - 290
  • [24] Enzyme-free electrochemical immunosensor based on methylene blue and the electro-oxidation of hydrazine on Pt nanoparticles
    Dutta, Gorachand
    Nagarajan, Sureshbabu
    Lapidus, Lisa J.
    Lillehoj, Peter B.
    BIOSENSORS & BIOELECTRONICS, 2017, 92 : 372 - 377
  • [25] Electrochemical immunosensor for label free epidermal growth factor receptor (EGFR) detection
    Vasudev, Abhay
    Kaushik, Ajeet
    Bhansali, Shekhar
    BIOSENSORS & BIOELECTRONICS, 2013, 39 (01): : 300 - 305
  • [26] An ecofriendly iron MOF-based immunosensor for sensitive detection of vascular endothelial growth factor in the serum of cancer patients
    Zizzari, Ilaria Grazia
    Gigli, Valeria
    Gentili, Tommaso
    Tortolini, Cristina
    Latini, Alessandro
    Rughetti, Aurelia
    di Gregorio, Maria Chiara
    Isidori, Andrea
    Nuti, Marianna
    Antiochia, Riccarda
    NANOSCALE, 2025, 17 (14) : 8790 - 8802
  • [27] Highly sensitive enzyme-free glucose sensor based on CuO-NiO nanocomposites by electrospinning
    Xu, Yanhong
    Ding, Yaping
    Zhang, Lihong
    Zhang, Xinxin
    COMPOSITES COMMUNICATIONS, 2021, 25
  • [28] A Novel MXene@MOF@Pt NPs-Based Enzyme-Free Electrochemical Sensor for Highly Sensitive Detection of Hydrogen Peroxide Released from Living Cells
    Wen, Wenbin
    Dang, Yuan
    Tang, Jieli
    Su, Changluo
    Yu, Sha
    Ma, Junping
    Zhou, Yuanzhen
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (05)
  • [29] Recent advances in enzyme-free electrochemical hydrogen peroxide sensors based on carbon hybrid nanocomposites
    Hu, Yue
    Hojamberdiev, Mirabbos
    Geng, Dongsheng
    JOURNAL OF MATERIALS CHEMISTRY C, 2021, 9 (22) : 6970 - 6990
  • [30] Label-free electrochemical immunosensor for rapid and highly sensitive detection of Brucella abortus in serum
    Chi, Yu
    Cao, Yu
    Cao, Wen-Xuan
    Ma, Lei
    Liu, Ming
    Li, Hai-Bo
    MICROCHEMICAL JOURNAL, 2024, 207