Dynamic response analyses of long-span cable-stayed bridges subjected to pulse-type ground motions

被引:25
作者
Jia, Hongyu [1 ]
Liu, Zhi [2 ]
Xu, Li [2 ]
Bai, Hao [3 ]
Bi, Kaiming [4 ]
Zhang, Chao [2 ]
Zheng, Shixiong [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Civil Engn, Chengdu 610031, Peoples R China
[2] Fuzhou Univ, Coll Civil Engn, Fuzhou 350116, Peoples R China
[3] Sichuan Expressway Construct & Dev Grp Co Ltd, Chengdu 610041, Peoples R China
[4] Curtin Univ, Ctr Infrastruct Monitoring & Protect, Sch Civil Engn & Mech, Kent St, Bentley, WA 6102, Australia
基金
美国国家科学基金会;
关键词
Long-span cable-stayed bridge; Pulse-type ground motion; Shaking table test; Seismic response; Structure analysis; 1988 SAGUENAY EARTHQUAKE; NEAR-FAULT; DAMAGE; DIRECTIVITY; BUILDINGS; BEHAVIOR; SPECTRA; MODEL;
D O I
10.1016/j.soildyn.2022.107591
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
This paper presents the dynamic response analyses of a special long-span cable-stayed bridge with the main span length of 680 (m) subjected to pulse-type ground motions. The 1/100 scaled shaking table test are developed herein to verify the accuracy and correctness of the 3D finite element (FE) model of the examined long-span cable-stayed bridge on the software platform of SAP2000. To systematically investigate the influence on the seismic responses and on the selection of the nonlinear viscous damper parameters of the employed long-span cable-stayed bridge both the near-fault pulse-type ground motions and the far-field ground motions are selected as the seismic inputs of FE model. Some important conclusions are drawn that the near-fault ground motions usually causes the larger peak responses (e.g., Tower top displacement, girder end displacement, and moment of tower bottom) of the long-span cable-stayed bridge compared with the far-field motions, namely the near-fault ground motions are more destructive to the structures. The displacement responses can be amplified approximately 2-3 times and the damper parameters (Damping coefficient C and damping index alpha) of nonlinear viscous dampers can be affected by the ground motion characteristics. The damper parameter values are changed from the C = 3000 and alpha = 0.3 in far-field earthquakes to the C = 6000 and alpha = 0.2 in near-fault earthquakes, namely the near-fault ground motions obviously increase the demand of energy consumption of general nonlinear viscous dampers.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Seismic Performance of a Long-Span Cable-Stayed Bridge under Spatially Varying Bidirectional Spectrum-Compatible Ground Motions
    Kim, Taeyong
    Kwon, Oh-Sung
    Song, Junho
    JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (04)
  • [32] Dynamic Response of Railway Vehicles Running on Long-Span Cable-Stayed Bridge Under Uniform Seismic Excitations
    Li, Yongle
    Zhu, Siyu
    Cai, C. S.
    Yang, Cheng
    Qiang, Shizhong
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2016, 16 (05)
  • [33] Transverse response of pile group foundations supporting a long-span cable-stayed bridge under uniform and nonuniform excitation
    Liang, Fayun
    Jia, Yajie
    Xie, Wen
    Sun, Limin
    Chen, Haibing
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2019, 121 : 57 - 74
  • [34] Long-span cable-stayed bridge with hybrid arrangement of FRP cables
    Yang, Yaqiang
    Wang, Xin
    Wu, Zhishen
    COMPOSITE STRUCTURES, 2020, 237
  • [35] Seismic fragility analyses of sea-crossing cable-stayed bridges subjected to multi-support ground motions on offshore sites
    Li, Chao
    Li, Hong-Nan
    Hao, Hong
    Bi, Kaiming
    Chen, Baokui
    ENGINEERING STRUCTURES, 2018, 165 : 441 - 456
  • [36] Seismic performance analysis of long-span cable-stayed bridges using stainless steel buckling-restrained braces
    Li, Xiaoli
    Guo, Yu
    Su, Shengkang
    Zou, Jina
    Wang, Dongsheng
    STRUCTURES, 2025, 75
  • [37] Analysis of Seismic Fragility and Recoverability of Long-Span Cable-Stayed Bridge
    Wu F.
    Meng Y.
    Chen Y.
    Ji Q.
    Yang Y.
    Wu Z.
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2020, 55 (01): : 126 - 133
  • [38] Dynamic behavior and seismic response of a long span partial cable-stayed bridge
    Chen, Zhijun
    Li, Li
    Tang, Jiaxiang
    Zhu, Anjing
    ISISS 2005: Innovation & Sustainability of Structures, Vol 1-3, 2005, : 1350 - 1358
  • [39] Study of super long span cable-stayed bridges with CFRP components
    Xiong, Wen
    Cai, C. S.
    Zhang, Yin
    Xiao, Rucheng
    ENGINEERING STRUCTURES, 2011, 33 (02) : 330 - 343
  • [40] Puqian Bridge: A Long-Span Cable-Stayed Bridge in a Meizoseismal Area
    Wu, Jingwu
    Xia, Ye
    Sun, Pingkuan
    Yu, Deen
    Sun, Limin
    STRUCTURAL ENGINEERING INTERNATIONAL, 2023, 33 (01) : 64 - 67