Accurate Voltage Phasor Measurement for Electric Power Transmission Line Protection Using Current Sensor

被引:1
|
作者
Mohanty, Rabindra [1 ]
Pradhan, Ashok Kumar [2 ]
Dutta, Pranab Kumar [2 ]
机构
[1] Indian Inst Technol Delhi, Dept Energy Sci & Engn, New Delhi 110016, India
[2] Indian Inst Technol Kharagpur, Dept Elect Engn, Kharagpur 721302, India
关键词
Sensor signal processing; capacitor voltage transformer (CVT); directional and distance protections; phasor estimation; transient response;
D O I
10.1109/LSENS.2023.3349322
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Accurate voltage phasor measurement is important for differ-ent applications in electric power systems including protection, control, and monitoring. At power transmission level, the transient response of the capacitor voltage transformer is a concern for the phasor based protection applications. This letter presents an accurate voltage phasor measurement technique at an electric bus during transient using the current through the capacitor voltage transformer. The numerical integration of current is multiplied with current transformer ratio and with the reciprocal of equivalent capacitance of the capacitor voltage transformer to obtain the accurate voltage during transient. The dependency of the obtained voltage accuracy on the current measurement error is also analyzed. The performance of the proposed technique for phasor estimation used in directional and distance protections during capacitor voltage transformer transient is demonstrated and found to be accurate. The performance of the proposed method is free from the capacitor voltage transformer topologies and operating conditions of electric power systems.
引用
收藏
页码:1 / 4
页数:4
相关论文
共 50 条
  • [31] Zero sequence power line current measurement by using magnetic field sensor array
    Lin, Shunfu
    Gao, Pengfei
    Xu, Wilsun
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2015, 25 (09): : 1685 - 1696
  • [32] Design and realization of an accurate built-in current sensor for on-line power dissipation measurement and IDDQ testing
    Arabi, K
    Kaminska, B
    ITC - INTERNATIONAL TEST CONFERENCE 1997, PROCEEDINGS: INTEGRATING MILITARY AND COMMERCIAL COMMUNICATIONS FOR THE NEXT CENTURY, 1997, : 578 - 586
  • [33] Fault Location Scheme on a Three Phase Transmission Line using Synchronized Phasor Measurement
    Anees, Ahmed Sharique
    Jamil, Majid
    Rizwan, M.
    2012 IEEE 5TH INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE 2012), 2012,
  • [34] Online identification of power transformer and transmission line parameters using synchronized voltage and current phasors
    Rezaei, Mohammad Reza
    Hadian-amrei, Seyed Reza
    Miveh, Mohammad Reza
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 203
  • [35] High speed accurate transmission line distance protection using ANNs
    Sanaye-Pasand, M
    Khorashadi-Zadeh, H
    Malik, OP
    2001 POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS, 2001, : 127 - 132
  • [36] Communication technology of digital current differential protection for high voltage transmission line
    North China Electric Power Univ, Beijing, China
    Dianli Xitong Zidonghue, 18 (25-27, 31):
  • [37] CURRENT LOAD IN A HIGH-VOLTAGE POWER TRANSMISSION-LINE
    LIN, SH
    ELECTRIC POWER SYSTEMS RESEARCH, 1991, 21 (03) : 181 - 185
  • [38] Investigation and Development of High Voltage Electric Power Line Protection Using Linear Integrated Circuits.
    Alekseeva, O.N.
    Ginovker, A.M.
    Egovskii, A.A.
    Khalikulov, I.B.
    Trudy LPI, 1980, (369): : 44 - 47
  • [39] Relevance of adaptive protection scheme using phasor measurement unit in Indian power grid
    Kumar D.S.
    Savier J.S.
    International Journal of Power Electronics, 2019, 10 (1-2) : 33 - 484
  • [40] Phasor Measurement Application for Power System Voltage Stability Monitoring
    Fu, Le
    Pal, Bikash C.
    Cory, Brian J.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 4953 - 4960