Martian flow characterization using tunable diode laser absorption spectroscopy, in high enthalpy facilities

被引:2
|
作者
Salvi, Ciro [1 ]
Steffens, Lars [2 ]
Hohn, Oliver [1 ]
Guelhan, Ali [1 ]
Maggi, Filippo [3 ]
机构
[1] German Aerosp Ctr DLR, Superson & Hyperson Technol Dept, D-51147 Cologne, Germany
[2] German Aerosp Ctr DLR, Safety Crit Data Infrastruct Dept, D-51147 Cologne, Germany
[3] Politecn Milan, Dept Aerosp Sci & Technol DAER, Via La Masa 34, I-20156 Milan, Italy
关键词
TDLAS; DLAS; Non intrusive; Hypersonic; High enthalpy; Arc-heated wind tunnel; Mars; MU-M; CO;
D O I
10.1016/j.actaastro.2023.08.043
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
This research aims at analyzing thermo-chemical properties of the hypersonic high-enthalpy flow in the L2K wind tunnel, situated in Koln at the German Aerospace Center (DLR). In the L2K wind tunnel, Martian atmosphere can be created, and the facility can simulate heat load conditions encountered during atmospheric entry of Martian missions. The focus of this project is the analysis of the non-intrusive experimental technique "Tunable Diode Laser Absorption Spectroscopy"(TDLAS), based on line of sight absorption spectroscopy, and applied to hypersonic flow. A simplified Martian atmosphere (97% CO2 and 3% N2) was used. A new interpretation for CO-TDLAS experimental technique applied to hypersonic wind tunnel flow analysis was developed. Numerical simulations with the DLR-TAU non-equilibrium flow solver were used as support of this analysis, and match between simulations and experiments was observed. Flow speed and absorption line's width were measured, and the knowledge of L2K's flow structure was extended.
引用
收藏
页码:204 / 214
页数:11
相关论文
共 50 条
  • [21] Large scale gas leakage monitoring with tunable diode laser absorption spectroscopy
    阚瑞峰
    刘文清
    张玉钧
    刘建国
    王敏
    陈东
    陈玖英
    崔益本
    Chinese Optics Letters, 2006, (02) : 116 - 118
  • [22] Automotive exhaust gas analysis by infrared tunable diode laser absorption spectroscopy
    Louvet, Y
    deBorniol, E
    Henry, D
    Mohamed, A
    Rosier, B
    Jones, W
    COMBUSTION DIAGNOSTICS, 1997, 3108 : 54 - 62
  • [23] Enhancement of Methane Detection in Tunable Diode Laser Absorption Spectroscopy Using Savitzky-Golay Filtering
    Chen, Shichao
    Tian, Xing
    Mu, Tong
    Yuan, Jun
    Cao, Xile
    Cheng, Gang
    PHOTONICS, 2025, 12 (01)
  • [24] Following fuel conversion during biomass gasification using tunable diode laser absorption spectroscopy diagnostics
    Sepman, Alexey
    Wennebro, Jonas
    Fernberg, Johannes
    Wiinikka, Henrik
    FUEL, 2024, 374
  • [25] Development and Metrological Characterization of a Tunable Diode Laser Absorption Spectroscopy (TDLAS) Spectrometer for Simultaneous Absolute Measurement of Carbon Dioxide and Water Vapor
    Pogany, Andrea
    Wagner, Steven
    Werhahn, Olav
    Ebert, Volker
    APPLIED SPECTROSCOPY, 2015, 69 (02) : 257 - 268
  • [26] Near-Surface Carbon-Dioxide Tunable Diode Laser Absorption Spectroscopy Concentration Measurements in Hypervelocity Flow
    Weisberger, Joshua M.
    DesJardin, Paul E.
    MacLean, Matthew
    Parker, Ronald
    Carr, Zakery
    JOURNAL OF SPACECRAFT AND ROCKETS, 2015, 52 (06) : 1551 - 1562
  • [27] Measurement of transient gas flow parameters by diode laser absorption spectroscopy
    Bolshov, M. A.
    Kuritsyn, Yu. A.
    Liger, V. V.
    Mironenko, V. R.
    Nadezhdinskii, A. I.
    Ponurovskii, Ya. Ya.
    Leonov, S. B.
    Yarantsev, D. A.
    QUANTUM ELECTRONICS, 2015, 45 (04) : 377 - 384
  • [28] The Development of Ammonia Sensor Based on Tunable Diode Laser Absorption Spectroscopy with Hollow Waveguide
    Du Zhen-hui
    Zhang Zhe-yuan
    Li Jin-yi
    Xiong Bo
    Zhen Wei-meng
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (08) : 2669 - 2673
  • [29] OXYGEN CONCENTRATION AND TEMPERATURE SIMULTANEOUS MEASUREMENT BASED ON TUNABLE DIODE LASER ABSORPTION SPECTROSCOPY
    Zhang, Chun-Xiao
    Wang, Fei
    Zheng, Qi-Ming
    Yan, Jianhua
    Chi, Yong
    Cen, Ke-fa
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON POWER ENGINEERING 2009 (ICOPE-09), VOL 2, 2009, : 147 - 150
  • [30] Correction of Gas Concentration Based on Tunable Diode Laser Absorption Spectroscopy in Different Temperatures
    Qu, Ziqi
    Zhang, Shiling
    Xu, Yuxin
    Jiang, Meng
    Wang, Junlong
    SECOND SYMPOSIUM ON NOVEL TECHNOLOGY OF X-RAY IMAGING, 2019, 11068