X-Ray Characteristics of Four-Level Pulse Amplitude Modulation for X-Ray Communication Based on Carbon Nanotube Cold Cathode X-Ray Source

被引:4
作者
Lai, Sheng [1 ]
Liu, Yunpeng [1 ,2 ]
Hang, Shuang [3 ]
Mu, Junxu [1 ]
Tang, Xiaobin [1 ,2 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Dept Nucl Sci & Technol, Nanjing 210016, Peoples R China
[2] Minist Ind & Informat Technol, Key Lab Nucl Technol Applicat & Radiat Protect Ast, Nanjing 210016, Peoples R China
[3] Acad Mil Sci, Strateg Assessments & Consultat Inst, Beijing 100091, Peoples R China
关键词
Carbon nanotube (CNT) cold cathode X-ray source; high-frequency pulse signal; pulse amplitude modulation with four level (PAM-4); X-ray communication (XCOM); FIELD-EMISSION; FABRICATION;
D O I
10.1109/TED.2023.3309276
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, a pulse amplitude modulation with four-level (PAM-4) signal loading scheme based on carbon nanotube (CNT) cold cathode X-ray source is designed for X-ray communication (XCOM). The relationship between the X-ray waveforms and amplitude characteristics under this scheme is studied, and the XCOM performance is obtained. Results show that the amplitude difference of each level of X-ray waveforms is obvious, and it is corresponding well with the input signal amplitude. The X-ray amplitude difference of each level is 0.7-0.8 V when the ratio of the four pulse voltage signal amplitudes is 1:0.42: -0.12: -1. About 70% of the signal waveforms of each level is relatively concentrated under different frequencies, and this proves the stability and feasibility of the PAM-4 loading scheme. According to the 26-letter American standard code for information interchange (ASCII) code signal transmission experiment, the bit error rate (BER) is increased from 0 to 4.7 x 10(-2) when the pulse frequency increases from 1 to 1000 kHz. This work designs a PAM-4 signal loading scheme for XCOM with a CNT cold cathode X-ray source, which can promote the development of XCOM technology in the future.
引用
收藏
页码:5877 / 5882
页数:6
相关论文
共 50 条
[31]   X-ray Focusing and Optics [J].
Salditt, Tim ;
Osterhoff, Markus .
NANOSCALE PHOTONIC IMAGING, 2020, 134 :71-124
[32]   Synchrotron X-Ray Optics [J].
Macrander, Albert T. ;
Huang, XiangRong .
ANNUAL REVIEW OF MATERIALS RESEARCH, VOL 47, 2017, 47 :135-152
[33]   Miniature X-Ray Sources [J].
Gorecka-Drzazga, Anna .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2017, 26 (01) :295-302
[34]   Micro Computed Tomography System Based on Field Emission X-Ray Source with Carbon Nanotube Emitter [J].
Kim, Wooseob ;
Gupta, Amar Prasad ;
Jang, Jaekyu ;
Jung, Jaeik ;
Ryu, Jehwang .
MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
[35]   Field Emission X-Ray Devices [J].
Wang, Jiaqi ;
Wang, Lang ;
Yeow, John T. W. .
IEEE NANOTECHNOLOGY MAGAZINE, 2025, 19 (04) :26-36
[36]   X-ray characterization of thin foil gold mirrors of a soft X-ray telescope for ASTROSAT [J].
Sagdeo, Archna ;
Rai, S. K. ;
Lodha, Gyan S. ;
Singh, K. P. ;
Yadav, Nisha ;
Dhawan, R. ;
Tonpe, Umesh ;
Vahia, M. N. .
EXPERIMENTAL ASTRONOMY, 2010, 28 (01) :11-23
[37]   INCREASED X-RAY OPACITY OF GDP CAPSULES FROM HIGH INTENSITY X-RAY EXPOSURE [J].
Sequoia, K. L. ;
Huang, H. ;
Stephens, R. B. ;
Moreno, K. A. ;
Chen, K. C. ;
Nikroo, A. .
FUSION SCIENCE AND TECHNOLOGY, 2011, 59 (01) :35-38
[38]   Transient nuclear inversion by x-ray free electron laser in a tapered x-ray waveguide [J].
Chen, Yu-Hsueh ;
Lin, Po-Han ;
Wang, Guan-Ying ;
Palffy, Adriana ;
Liao, Wen-Te .
PHYSICAL REVIEW RESEARCH, 2022, 4 (03)
[39]   X-RAY LITHOGRAPHY USING CHLORINATED POLYMETHYLSTYRENE (CPMS) AS A NEGATIVE X-RAY RESIST. [J].
Suzuki, Yoshiki ;
Ishio, Noriaki ;
Eimori, Takahisa ;
Yoshioka, Nobuyuki ;
Watakabe, Yaichiro ;
Yamazaki, Teruhiko .
Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes, 1987, 26 (01) :130-135
[40]   Optimum design for the carbon nanotube based micro-focus X-ray tube [J].
Kim, Hyun Suk ;
Castro, Edward Joseph D. ;
Lee, Choong Hun .
VACUUM, 2015, 111 :142-149