X-Ray Characteristics of Four-Level Pulse Amplitude Modulation for X-Ray Communication Based on Carbon Nanotube Cold Cathode X-Ray Source

被引:3
|
作者
Lai, Sheng [1 ]
Liu, Yunpeng [1 ,2 ]
Hang, Shuang [3 ]
Mu, Junxu [1 ]
Tang, Xiaobin [1 ,2 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Dept Nucl Sci & Technol, Nanjing 210016, Peoples R China
[2] Minist Ind & Informat Technol, Key Lab Nucl Technol Applicat & Radiat Protect Ast, Nanjing 210016, Peoples R China
[3] Acad Mil Sci, Strateg Assessments & Consultat Inst, Beijing 100091, Peoples R China
关键词
Carbon nanotube (CNT) cold cathode X-ray source; high-frequency pulse signal; pulse amplitude modulation with four level (PAM-4); X-ray communication (XCOM); FIELD-EMISSION; FABRICATION;
D O I
10.1109/TED.2023.3309276
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, a pulse amplitude modulation with four-level (PAM-4) signal loading scheme based on carbon nanotube (CNT) cold cathode X-ray source is designed for X-ray communication (XCOM). The relationship between the X-ray waveforms and amplitude characteristics under this scheme is studied, and the XCOM performance is obtained. Results show that the amplitude difference of each level of X-ray waveforms is obvious, and it is corresponding well with the input signal amplitude. The X-ray amplitude difference of each level is 0.7-0.8 V when the ratio of the four pulse voltage signal amplitudes is 1:0.42: -0.12: -1. About 70% of the signal waveforms of each level is relatively concentrated under different frequencies, and this proves the stability and feasibility of the PAM-4 loading scheme. According to the 26-letter American standard code for information interchange (ASCII) code signal transmission experiment, the bit error rate (BER) is increased from 0 to 4.7 x 10(-2) when the pulse frequency increases from 1 to 1000 kHz. This work designs a PAM-4 signal loading scheme for XCOM with a CNT cold cathode X-ray source, which can promote the development of XCOM technology in the future.
引用
收藏
页码:5877 / 5882
页数:6
相关论文
共 50 条
  • [1] X-ray ultrashort pulse emission characteristic of carbon nanotube cold cathode X-ray source by pulse driving mode
    Lai, Sheng
    Liu, Yunpeng
    Mu, Junxu
    Feng, Zhaopeng
    Miao, Kai
    Tang, Xiaobin
    VACUUM, 2023, 207
  • [2] Compact X-ray tube based on carbon nanotube cold cathode emitter for handheld type X-ray application
    Lim, Jongmin
    Gupta, Amar P.
    Choi, Jinho
    Rajpoot, Shalini
    Jung, Jaeik
    Jang, Jaekyu
    Yeo, Seung Jun
    Ahn, Jeung Sun
    Ryu, Jehwang
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [3] Development of gated carbon nanotube cold cathode for miniature X-ray source
    Guo, Yajie
    Wang, Junfan
    Li, Baohong
    Zhang, Yu
    Deng, Shaozhi
    Xu, Ningsheng
    Chen, Jun
    2021 34TH INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE (IVNC), 2021, : 189 - 190
  • [4] Biomedical X-ray Imaging Enabled by Carbon Nanotube X-ray Sources
    Cao, Guohua
    CHINESE JOURNAL OF CHEMICAL PHYSICS, 2018, 31 (04) : 529 - 536
  • [5] Optimization of Ballasted Carbon Nanotube Array for X-ray Source
    Sun, Yonghai
    Yeow, John T. W.
    Jaffray, David A.
    2013 13TH IEEE CONFERENCE ON NANOTECHNOLOGY (IEEE-NANO), 2013, : 389 - 392
  • [6] Microfocus X-Ray Tubes with a Silicon Autoemission Nanocathode as an X-Ray Source
    N. A. Dyuzhev
    G. D. Demin
    T. A. Gryazneva
    A. E. Pestov
    N. N. Salashchenko
    N. I. Chkhalo
    F. A. Pudonin
    Bulletin of the Lebedev Physics Institute, 2018, 45 : 1 - 5
  • [7] Grating-Based X-ray Phase Imaging Using Multiline X-ray Source
    Momose, Atsushi
    Yashiro, Wataru
    Kuwabara, Hiroaki
    Kawabata, Katsuyuki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2009, 48 (07)
  • [8] Microfocus X-Ray Tubes with a Silicon Autoemission Nanocathode as an X-Ray Source
    Dyuzhev, N. A.
    Demin, G. D.
    Gryazneva, T. A.
    Pestov, A. E.
    Salashchenko, N. N.
    Chkhalo, N. I.
    Pudonin, F. A.
    BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2018, 45 (01) : 1 - 5
  • [9] Achieving High Current Stability of Gated Carbon Nanotube Cold Cathode Electron Source Using IGBT Modulation for X-ray Source Application
    Guo, Yajie
    Wang, Junfan
    Li, Baohong
    Zhang, Yu
    Deng, Shaozhi
    Chen, Jun
    NANOMATERIALS, 2022, 12 (11)
  • [10] Cold cathode x-ray source fabricated by the CNT point emitter
    Lee, Sang Heon
    Han, Jun Soo
    Go, Han Bin
    Lee, Cheol Jin
    2017 30TH INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE (IVNC), 2017, : 64 - 65