Design of a piezoelectrically actuated hydrocephalus shunt valve

被引:0
作者
Salih, O. [1 ]
Messina, M. [2 ]
Al-Jumeily, D. [3 ]
机构
[1] Liverpool John Moores Univ, Engn & Technol Res Inst, Liverpool, Merseyside, England
[2] Liverpool John Moores Univ, Mech Engn Dept, Liverpool, Merseyside, England
[3] Liverpool John Moores Univ, Sch Comp Sci & Math, Liverpool, Merseyside, England
关键词
Actuation; Hydrocephalus; Mechatronic valve; Piezoelectric; Shunt; Ultra-sonic motor; CEREBROSPINAL-FLUID; PRESSURE;
D O I
10.1007/s11517-023-02822-1
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Hydrocephalus is currently managed by using traditional mechanical passive shunts. Due to their nature, these shunts have fundamental shortcomings including an increase in patient shunt dependency, absence of fault detection, and over drainage due to lack of shunt proactivity. There is a scientific consensus that the way forward to address these issues is through what is termed a smart shunt. The core component of this system is the mechatronic controllable valve. A design of a valve which utilises both the passive nature of the classical valves and the controllability feature of the fully automated valves is presented in this paper. The valve consists of a fluid compartment, a linear spring, and an ultrasonic piezoelectric element. The valve is designed to operate on a 5 V supply, to drain up to 300 mL/h, and it has an operational range between 10 and 20 mmHg. The design produced is considered feasible as it takes into consideration the multiple operation conditions associated with such an implanted system.
引用
收藏
页码:2281 / 2290
页数:10
相关论文
共 27 条
  • [1] Amar K., 2013, INTRO FINITE ELEMENT, P5
  • [2] Shunt Complications - Staying Out of Trouble
    Balasubramaniam, Chidambaram
    [J]. NEUROLOGY INDIA, 2021, 69 : S476 - S482
  • [3] Ventricular shunts
    Chabrerie, A
    Black, PM
    [J]. JOURNAL OF INTENSIVE CARE MEDICINE, 2002, 17 (05) : 218 - 229
  • [4] Design and characterization of a passive flow control valve dedicated to the hydrocephalus treatment
    Chappel, Eric
    [J]. COGENT ENGINEERING, 2016, 3 (01):
  • [5] Cerebrospinal fluid shunts - How they work: The basics
    Chatterjee, Sandip
    Harischandra, L.
    [J]. NEUROLOGY INDIA, 2018, 66 (01) : 24 - 35
  • [6] Chin W., 2001, COMPUTATIONAL RHEOLO, P168, DOI [10.1016/B978-088415320-7/50007-5, DOI 10.1016/B978-088415320-7/50007-5]
  • [7] Development of MEMS-based cerebrospinal fluid shunt system
    Chung, S
    Kim, JK
    Wang, KC
    Han, DC
    Chang, JK
    [J]. BIOMEDICAL MICRODEVICES, 2003, 5 (04) : 311 - 321
  • [8] What is normal intra-abdominal pressure and how is it affected by positioning, body mass and positive end-expiratory pressure?
    De Keulenaer, B. L.
    De Waele, J. J.
    Powell, B.
    Malbrain, M. L. N. G.
    [J]. INTENSIVE CARE MEDICINE, 2009, 35 (06) : 969 - 976
  • [9] Cerebrospinal Fluid and Hydrocephalus: Physiology, Diagnosis, and Treatment
    Filis, Andreas K.
    Aghayev, Kamran
    Vrionis, Frank D.
    [J]. CANCER CONTROL, 2017, 24 (01) : 6 - 8
  • [10] A MEMS-based passive hydrocephalus shunt for body position controlled intracranial pressure regulation
    Johansson, Staffan B.
    Eklund, Anders
    Malm, Jan
    Stemme, Goran
    Roxhed, Niclas
    [J]. BIOMEDICAL MICRODEVICES, 2014, 16 (04) : 529 - 536