Adaptive Ultrasonic Imaging Total Focusing Method Based on Covariance Correlation Weighting Factor

被引:2
作者
Liu, Lang [1 ]
Gao, Xiaorong [1 ]
Peng, Jianping [1 ]
Luo, Lin [1 ]
Li, Jinlong [1 ]
Zhang, Yu [1 ]
机构
[1] Southwest Jiaotong Univ, NDT Researcher Ctr, Sch Phys Sci & Technol, Chengdu 610031, Peoples R China
关键词
Covariance correlation weighting factor; Adaptive total focusing method; Signal processing; Non-destructive evaluation; FULL MATRIX CAPTURE; COMPONENTS; INSPECTION; GEOMETRY; ARRAYS; MODEL;
D O I
10.1007/s10921-023-00927-z
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Total focusing method imaging is a phased array (PA) post-processing imaging method based on full matrix acquisition data with high resolution and high signal-to-noise ratio. However, the placement of the probe is largely limited by the shape of the detection surface. In this paper, a water membrane PA probe that can perform in-service detection of unknown interface objects in indirect water immersion mode is used, and a covariance correlation weighting factor for optimizing adaptive Total focusing method (ATFM) imaging results is proposed. Experiments of artificial test block and actual wheel rim have shown that the ATFM can not only identify the profile of the unknown interface, but also image the interior of the test object. Furthermore, the contrast signal-to-noise ratio of the defect signal is increased by 40 dB on average, and the defect resolution is also Improved. This method, meanwhile, can truly reflect the morphology of internal defects in actual inspection objects, which is conducive to non-destructive evaluation of defects.
引用
收藏
页数:12
相关论文
共 50 条
[31]   Optimal Design of Sparse Array for Ultrasonic Total Focusing Method by Binary Particle Swarm Optimization [J].
Zhang, Han ;
Bai, Bichao ;
Zheng, Jianfeng ;
Zhou, Yun .
IEEE ACCESS, 2020, 8 :111945-111953
[32]   Full Matrix Capture and the Total Focusing Imaging Algorithm Using Laser Induced Ultrasonic Phased Arrays [J].
Stratoudaki, Theodosia ;
Clark, Matt ;
Wilcox, Paul D. .
43RD REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, 2017, 1806
[33]   Three dimensional total focusing imaging of volumetric defects using laser diffuse ultrasonic phased arrays [J].
Li, Jun ;
Wilcox, Paul ;
Zhang, Jie .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2025, 230
[34]   An Integrated Method based on Entropy Weighting and Grey Correlation Analysis in Contractor Prequalification [J].
Gao, Xing ;
Cao, Ji-ming .
2012 2ND INTERNATIONAL CONFERENCE ON APPLIED SOCIAL SCIENCE (ICASS 2012), VOL 2, 2012, :149-154
[35]   Surface imaging using total focusing method on surface waves for non destructive testing [J].
Ducousso, Mathieu ;
Ghibaudo, Olivier ;
Amiel, Stephane .
NDT & E INTERNATIONAL, 2024, 146
[36]   Floquet wave theory-based time-corrected ultrasonic total focusing method for fiber-reinforced composite laminate [J].
Liu, Menglong ;
Xiao, Hai ;
Hu, Qi ;
Zhang, Zhen ;
Leung, Chung Ming .
ULTRASONICS, 2021, 116
[37]   Nondestructive testing of IV type hydrogen storage cylinder liner based on rotating water immersion ultrasonic total focusing method detection system [J].
Zheng, Shanpu ;
Teng, Guoyang ;
Miao, Cunjian ;
Lai, Yongqiang ;
Shi, Yan ;
Tang, Ping .
NONDESTRUCTIVE TESTING AND EVALUATION, 2025,
[38]   FEA-Based Ultrasonic Focusing Method in Anisotropic Media for Phased Array Systems [J].
Moon, Seongin ;
Kang, To ;
Han, Soonwoo ;
Kim, Kyung-Mo ;
Jin, Hyung-Ha ;
Kim, Sung-Woo ;
Kim, Munsung ;
Seo, Hyunil .
APPLIED SCIENCES-BASEL, 2021, 11 (19)
[39]   Laser induced ultrasonic phased array using full matrix capture data acquisition and total focusing method [J].
Stratoudaki, Theodosia ;
Clark, Matt ;
Wilcox, Paul D. .
OPTICS EXPRESS, 2016, 24 (19) :21921-21938
[40]   Total Focusing Method for Non Destructive Evaluation: Toward Real-Time Imaging Systems [J].
Njiki, Mickael ;
Elouardi, Abdelhafid ;
Bouaziz, Samir ;
Casula, Olivier ;
Roy, Olivier .
2013 IEEE 56TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2013, :1164-1167