Spectral and temporal detection of blood bilirubin level using a point-of-care device

被引:0
|
作者
Ndabakuranye, Jean Pierre [1 ]
Choy, Kay Weng [2 ]
Prawer, Steven [3 ]
Ahnood, Arman [1 ]
机构
[1] RMIT Univ, Sch Engn, Melbourne, Vic 3038, Australia
[2] Northern Hlth, Northern Pathol Victoria, Epping, Vic 3076, Australia
[3] Univ Melbourne, Sch Phys, Melbourne, Vic 3010, Australia
来源
2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC | 2023年
基金
澳大利亚研究理事会;
关键词
Biosensing; Bilirubin; Biomarker; Blood; Degradation; Point-of-Care; Translational medicine; SYSTEM;
D O I
10.1109/EMBC40787.2023.10340716
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Bilirubin is a biomarker for liver inflammation used to assess liver functions. Its concentration in the blood has been measured using a range of techniques both in clinical and point-of-care settings. Existing point-of-care devices utilize a spectral approach, namely dual-wavelength absorption measurement, to assess the blood bilirubin concentration. This work examines a novel temporal approach based on the photodegradation of bilirubin in the blood sample. It demonstrates that combining photodegradation characteristics with dual-wavelength measurement produces a more accurate technique for measuring blood bilirubin concentration. Tracking the evolution of absorbed light as a function of time represents a low-cost and simple way of improving the accuracy of point-of-care devices for bilirubin measurements.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Clozapine blood level assessment using a point-of-care device: feasibility and reliability
    Kamhi-Nesher, Shiri
    Taub, Sharon
    Halimi, Shikma
    Frenkel, Maria
    Azam, Mahmud
    Bormant, Gil
    Isakov, Helena
    Radzinsky, Dikla
    Weizman, Abraham
    Krivoy, Amir
    THERAPEUTIC ADVANCES IN PSYCHOPHARMACOLOGY, 2022, 12
  • [2] 175 Years of Bilirubin Testing: Ready for Point-of-Care?
    Guirguis, Natalie
    Bertrand, Antoine-Xavier
    Rose, Christopher F.
    Matoori, Simon
    ADVANCED HEALTHCARE MATERIALS, 2023, 12 (18)
  • [3] A paper-based point-of-care testing device for the colourimetric estimation of bilirubin in blood sample
    Devi, A. Lakshmi
    Resmi, P. E.
    Pradeep, Aarathi
    Suneesh, P. V.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 287
  • [4] An Instantaneous Low-Cost Point-of-Care Anemia Detection Device
    Punter-Villagrasa, Jaime
    Cid, Joan
    Paez-Aviles, Cristina
    Rodriguez-Villarreal, Ivon
    Juanola-Feliu, Esteve
    Colomer-Farrarons, Jordi
    Miribel-Catala, Pere Ll.
    SENSORS, 2015, 15 (02): : 4564 - 4577
  • [5] Plasmonic Point-of-Care Device for Sepsis Biomarker Detection
    Kundu, Souvik
    Tabassum, Shawana
    Kumar, Ratnesh
    IEEE SENSORS JOURNAL, 2021, 21 (17) : 18837 - 18846
  • [6] A Lateral Flow Device for Point-of-Care Detection of Doxorubicin
    Pomili, Tania
    Gatto, Francesca
    Pompa, Pier Paolo
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [7] Evaluation of a Point-of-Care Test for Bilirubin in Malawi
    Shapiro, Alyssa
    Anderson, Jessica
    Mtenthaonga, Prince
    Kumwenda, Watson
    Bond, Meaghan
    Schwarz, Richard
    Carns, Jennifer
    Johnston, Ryan
    Dube, Queen
    Chiume, Msandeni
    Richards-Kortum, Rebecca
    PEDIATRICS, 2022, 150 (02)
  • [8] Palm-Sized Device for Point-of-Care Ebola Detection
    Ahrberg, Christian D.
    Manz, Andreas
    Neuzil, Pavel
    ANALYTICAL CHEMISTRY, 2016, 88 (09) : 4803 - 4807
  • [9] Accuracy of a point-of-care blood lactate measurement device in a prehospital setting
    Louise Houlberg Walther
    Floor Zegers
    Mads Nybo
    Christian Backer Mogensen
    Erika Frischknecht Christensen
    Annmarie Touborg Lassen
    Søren Mikkelsen
    Journal of Clinical Monitoring and Computing, 2022, 36 : 1679 - 1687
  • [10] Accuracy of a point-of-care blood lactate measurement device in a prehospital setting
    Walther, Louise Houlberg
    Zegers, Floor
    Nybo, Mads
    Mogensen, Christian Backer
    Christensen, Erika Frischknecht
    Lassen, Annmarie Touborg
    Mikkelsen, Soren
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (06) : 1679 - 1687