An in vitro comparison of the marginal fit of provisional crowns using the virtual tooth preparation workflow against the traditional technique

被引:7
作者
Shenoy, Amrutha [1 ]
Maiti, Subhabrata [1 ,2 ]
Nallaswamy, Deepak [1 ]
Keskar, Varun [1 ]
机构
[1] Saveetha Univ, Saveetha Dent Coll & Hosp, Saveetha Inst Med & Tech Sci, Dept Prosthodont & Implantol, Chennai, Tamil Nadu, India
[2] Saveetha Univ, Saveetha Inst Med & Tech Sci, Saveetha Dent Coll & Hosp, Dept Prosthodont & Implantol, Chennai 600077, Tamil Nadu, India
关键词
Cone-beam computed tomography; digital dentistry; intraoral scan; marginal fit; virtual tooth preparation; ACCURACY;
D O I
10.4103/jips.jips_273_23
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: This study investigates the effectiveness of an innovative virtual tooth preparation workflow for the fabrication of dental crowns using cone-beam computed tomography (CBCT) and intraoral scanners (IOSs) with conventional workflow using extraoral/laboratory scanners.Settings and Design: This in vitro experimental study was conducted in the laboratory of a university in Chennai, India. The dental laboratory and research facilities at the institution were utilized for the fabrication of the temporary crowns and the data acquisition process.Materials and Methods: Institutional approval was obtained from the university. It was basically a comparison between the virtual prep technique using CBCT and IOS and the conventional digital technique using extra oral scanners (EOS) for temporary crown fabrication. The sample size was estimated using an effect size of 1.5004, assuming a normal distribution, a significance level of 0.05, and a power of 0.95 in G power software. Based on this calculation, an extracted second lower molar was used to fabricate 10 samples in each group. The samples were divided into three groups: the CBCT (Group 1), the IOS (Group 2), and laboratory scanner (Group 3 as control) groups. The vertical marginal gap of all the surfaces of the crown was evaluated using a scanning electron microscope.Statistical Analysis Used: Data were analyzed using one-way ANOVA using the SPSS software version 26.0, IBM, Armonk, NY, USA.Results: Acceptable marginal discrepancy values were obtained in all three groups. There was no significant difference in the marginal discrepancy recorded (P = 0.113).Conclusion: Virtual tooth preparation using CBCT and IOSs can be used as an alternative to the conventional workflow for provisional crown and bridge fabrication.
引用
收藏
页码:391 / 397
页数:7
相关论文
共 30 条
  • [1] Evaluation of Marginal and Internal Fit of Ceramic Laminate Veneers Fabricated with Five Intraoral Scanners and Indirect Digitization
    Al-Dwairi, Ziad N.
    Al-Sardi, Moataz
    Goodacre, Brian J.
    Goodacre, Charles J.
    Al Hamad, Khaled Q.
    Ozcan, Mutlu
    Al-Haj Husain, Nadin
    Baba, Nadim Z.
    [J]. MATERIALS, 2023, 16 (06)
  • [2] Attia MA., 2023, J Prosthet Dent, V129, p906.
  • [3] Correlation between polymerization shrinkage and marginal fit of temporary crowns
    Balkenhol, Markus
    Knapp, Michael
    Ferger, Paul
    Heun, Ulrich
    Woestmann, Bernd
    [J]. DENTAL MATERIALS, 2008, 24 (11) : 1575 - 1584
  • [4] Bhambhani Ritika, 2013, J Indian Prosthodont Soc, V13, P165, DOI 10.1007/s13191-012-0181-2
  • [5] Marginal and internal fit of provisional crowns fabricated using 3D printing technology
    Chaturvedi, Saurabh
    Alqahtani, Nasser M.
    Addas, Mohamed Khaled
    Alfarsi, Mohammed A.
    [J]. TECHNOLOGY AND HEALTH CARE, 2020, 28 (06) : 635 - 642
  • [6] Statistical power analyses using G*Power 3.1: Tests for correlation and regression analyses
    Faul, Franz
    Erdfelder, Edgar
    Buchner, Axel
    Lang, Albert-Georg
    [J]. BEHAVIOR RESEARCH METHODS, 2009, 41 (04) : 1149 - 1160
  • [7] CONSIDERATIONS IN MEASUREMENT OF MARGINAL FIT
    HOLMES, JR
    BAYNE, SC
    HOLLAND, GA
    SULIK, WD
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1989, 62 (04) : 405 - 408
  • [8] Marginal fit of CAD-CAM monolithic zirconia crowns fabricated by using cone beam computed tomography scans
    Kale, Ediz
    Cilli, Mesutcan
    Ozcelik, Tuncer Burak
    Yilmaz, Burak
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (05) : 731 - 737
  • [9] Evaluation of the Translucency Properties for CAD/CAM Full Ceramic Crowns Fabricated From Glass Ceramics (E.max) or High Translucency Zirconia (Lava Plus): A Clinical Study
    Kanout, Chaza
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [10] Can lithium disilicate ceramic crowns be fabricated on the basis of CBCT data?
    Kauling, Ana Elisa Colle
    Keul, Christine
    Erdelt, Kurt
    Kuehnisch, Jan
    Gueth, Jan-Frederik
    [J]. CLINICAL ORAL INVESTIGATIONS, 2019, 23 (10) : 3739 - 3748