Patient-specific quality assurance strategies for synthetic computed tomography in magnetic resonance-only radiotherapy of the abdomen

被引:8
|
作者
Dal Bello, Riccardo [1 ,2 ,5 ]
Lapaeva, Mariia [1 ,2 ,3 ,4 ]
La Greca Saint-Esteven, Agustina [1 ,2 ,4 ]
Wallimann, Philipp [1 ,2 ]
Gunther, Manuel [3 ]
Konukoglu, Ender [4 ]
Andratschke, Nicolaus [1 ,2 ]
Guckenberger, Matthias [1 ,2 ]
Tanadini-Lang, Stephanie [1 ,2 ]
机构
[1] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
[2] Univ Zurich, Zurich, Switzerland
[3] Univ Zurich, Dept Informat, Artificial Intelligence & Machine Learning Grp, Zurich, Switzerland
[4] Swiss Fed Inst Technol, Comp Vis Lab, Zurich, Switzerland
[5] Univ Spital Zurich USZ, Klin Radioonkol, Ramistr 100, CH-8091 Zurich, Switzerland
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2023年 / 27卷
关键词
MR-guided radiotherapy; synthetic CT; Neural network; Quality assurance; PSQA; MR-Linac; CT; GENERATION; MRI;
D O I
10.1016/j.phro.2023.100464
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: The superior tissue contrast of magnetic resonance (MR) compared to computed tomography (CT) led to an increasing interest towards MR-only radiotherapy. For the latter, the dose calculation should be performed on a synthetic CT (sCT). Patient-specific quality assurance (PSQA) methods have not been established yet and this study aimed to assess several software-based solutions.Materials and methods: A retrospective study was performed on 20 patients treated at an MR-Linac, which were selected to evenly cover four subcategories: (i) standard, (ii) air pockets, (iii) lung and (iv) implant cases. The neural network (NN) CycleGAN was adopted to generate a reference sCT, which was then compared to four PSQA methods: (A) water override of body, (B) five tissue classes with bulk densities, (C) sCT generated by a separate NN (pix2pix) and (D) deformed CT.Results: The evaluation of the dose endpoints demonstrated that while all methods A-D provided statistically equivalent results (p = 0.05) within the 2% level for the standard cases (i), only the methods C-D guaranteed the same result over the whole cohort. The bulk densities override was shown to be a valuable method in absence of lung tissue within the beam path.Conclusion: The observations of this study suggested that the use of an additional sCT generated by a separate NN was an appropriate tool to perform PSQA of a sCT in an MR-only workflow at an MR-Linac. The time and dose endpoints requirements were respected, namely within 10 min and 2%.
引用
收藏
页数:7
相关论文
共 46 条
  • [41] Is it necessary to perform measurement-based patient-specific quality assurance for online adaptive radiotherapy with Elekta Unity MR-Linac?
    Xu, Yuan
    Xia, Wenlong
    Ren, Wenting
    Ma, Min
    Men, Kuo
    Dai, Jianrong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (02):
  • [42] Feasibility of patient-specific quality assurance (PSQA) for real-time robotic stereotactic body radiotherapy (SBRT) based on tumor motion traces
    Xu, Qianyi
    Fan, Jiajin
    Vinogradskiy, Yevgeniy
    Chawla, Ashish K.
    Kubicek, Gregory
    Yang, Haihua
    Huynh, Kiet
    LaCouture, Tamara
    Grimm, Jimm
    Nie, Wei
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (08):
  • [43] A prospective study on the effect of tumor shrinkage on exit fluence gamma pass rate in high precision radiotherapy and influence of phantom setup error in patient-specific quality assurance
    Tiwari, Arnav
    Das, Saikat
    Pandey, Vindhyavasini P.
    Kharade, Vipin
    Gupta, Manish
    Pasricha, Rajesh
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2024, 20 (03) : 935 - 942
  • [44] Incorporating patient-specific information for the development of rectal tumor auto-segmentation models for online adaptive magnetic resonance Image-guided radiotherapy
    Kensen, Chavelli M.
    Simoes, Rita
    Betgen, Anja
    Wiersema, Lisa
    Lambregts, Doenja M. J.
    Peters, Femke P.
    Marijnen, Corrie A. M.
    van der Heide, Uulke A.
    Janssen, Tomas M.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 32
  • [45] Fluorine-18 Prostate-specific Membrane Antigen-1007 Positron Emission Tomography/Computed Tomography and Multiparametric Magnetic Resonance Imaging in Diagnostics of Local Recurrence in a Prostate Cancer Patient After Recent Radical Prostatectomy
    Paddubny, Kiryl
    Freitag, Martin T.
    Kratochwil, Clemens
    Koerber, Stefan
    Radtke, Jan P.
    Sakovich, Ruslan
    Kopka, Klaus
    Giesel, Frederik L.
    CLINICAL GENITOURINARY CANCER, 2018, 16 (02) : 103 - 105
  • [46] Patient-Specific 3-D Magnetic Resonance Imaging-Based Dynamic Simulation of Hip Impingement and Range of Motion Can Replace 3-D Computed Tomography-Based Simulation for Patients With Femoroacetabular Impingement: Implications for Planning Open Hip Preservation Surgery and Hip Arthroscopy
    Lerch, Till D.
    Degonda, Celia
    Schmaranzer, Florian
    Todorski, Inga
    Cullmann-Bastian, Jennifer
    Zheng, Guoyan
    Siebenrock, Klaus A.
    Tannast, Moritz
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2019, 47 (12) : 2966 - 2977