Patient-specific quality assurance strategies for synthetic computed tomography in magnetic resonance-only radiotherapy of the abdomen

被引:8
|
作者
Dal Bello, Riccardo [1 ,2 ,5 ]
Lapaeva, Mariia [1 ,2 ,3 ,4 ]
La Greca Saint-Esteven, Agustina [1 ,2 ,4 ]
Wallimann, Philipp [1 ,2 ]
Gunther, Manuel [3 ]
Konukoglu, Ender [4 ]
Andratschke, Nicolaus [1 ,2 ]
Guckenberger, Matthias [1 ,2 ]
Tanadini-Lang, Stephanie [1 ,2 ]
机构
[1] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
[2] Univ Zurich, Zurich, Switzerland
[3] Univ Zurich, Dept Informat, Artificial Intelligence & Machine Learning Grp, Zurich, Switzerland
[4] Swiss Fed Inst Technol, Comp Vis Lab, Zurich, Switzerland
[5] Univ Spital Zurich USZ, Klin Radioonkol, Ramistr 100, CH-8091 Zurich, Switzerland
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2023年 / 27卷
关键词
MR-guided radiotherapy; synthetic CT; Neural network; Quality assurance; PSQA; MR-Linac; CT; GENERATION; MRI;
D O I
10.1016/j.phro.2023.100464
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: The superior tissue contrast of magnetic resonance (MR) compared to computed tomography (CT) led to an increasing interest towards MR-only radiotherapy. For the latter, the dose calculation should be performed on a synthetic CT (sCT). Patient-specific quality assurance (PSQA) methods have not been established yet and this study aimed to assess several software-based solutions.Materials and methods: A retrospective study was performed on 20 patients treated at an MR-Linac, which were selected to evenly cover four subcategories: (i) standard, (ii) air pockets, (iii) lung and (iv) implant cases. The neural network (NN) CycleGAN was adopted to generate a reference sCT, which was then compared to four PSQA methods: (A) water override of body, (B) five tissue classes with bulk densities, (C) sCT generated by a separate NN (pix2pix) and (D) deformed CT.Results: The evaluation of the dose endpoints demonstrated that while all methods A-D provided statistically equivalent results (p = 0.05) within the 2% level for the standard cases (i), only the methods C-D guaranteed the same result over the whole cohort. The bulk densities override was shown to be a valuable method in absence of lung tissue within the beam path.Conclusion: The observations of this study suggested that the use of an additional sCT generated by a separate NN was an appropriate tool to perform PSQA of a sCT in an MR-only workflow at an MR-Linac. The time and dose endpoints requirements were respected, namely within 10 min and 2%.
引用
收藏
页数:7
相关论文
共 46 条
  • [21] Developing quality assurance tests for simultaneous Positron Emission Tomography - Magnetic Resonance imaging for radiotherapy planning
    Wyatt, Jonathan J.
    McCallum, Hazel M.
    Maxwell, Ross J.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 22 : 28 - 35
  • [22] Comparison of Synthetic Computed Tomography Generation Methods, Incorporating Male and Female Anatomical Differences, for Magnetic Resonance Imaging-Only Definitive Pelvic Radiotherapy
    O'Connor, Laura M.
    Choi, Jae H.
    Dowling, Jason A.
    Warren-Forward, Helen
    Martin, Jarad
    Greer, Peter B.
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [23] Deep Hybrid Learning Prediction of Patient-Specific Quality Assurance in Radiotherapy: Implementation in Clinical Routine
    Moreau, Noemie
    Bonnor, Laurine
    Jaudet, Cyril
    Lechippey, Laetitia
    Falzone, Nadia
    Batalla, Alain
    Bertaut, Cindy
    Corroyer-Dulmont, Aurelien
    DIAGNOSTICS, 2023, 13 (05)
  • [24] Dosimetric evaluation of synthetic CT relative to bulk density assignment-based magnetic resonance-only approaches for prostate radiotherapy
    Joshua Kim
    Kim Garbarino
    Lonni Schultz
    Kenneth Levin
    Benjamin Movsas
    M. Salim Siddiqui
    Indrin J. Chetty
    Carri Glide-Hurst
    Radiation Oncology, 10
  • [25] Cone beam computed tomography based image guidance and quality assessment of prostate cancer for magnetic resonance imaging-only radiotherapy in the pelvis
    Edmund, Jens M.
    Andreasen, Daniel
    Van Leemput, Koen
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 18 : 55 - 60
  • [26] A comparison of three-film analysis software for stereotactic radiotherapy patient-specific quality assurance
    Buddhavarapu, Athreya
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (03):
  • [27] Usefulness of a new online patient-specific quality assurance system for respiratory-gated radiotherapy
    Kurosawa, Tomoyuki
    Tachibana, Hidenobu
    Moriya, Shunsuke
    Miyakawa, Shin
    Nishio, Teiji
    Sato, Masanori
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 43 : 63 - 72
  • [28] Evaluation of a deep learning magnetic resonance imaging reconstruction method for synthetic computed tomography generation in prostate radiotherapy
    Olsson, Lars E.
    af Wetterstedt, Sacha
    Scherman, Jonas
    Gunnlaugsson, Adalsteinn
    Persson, Emilia
    Gustafsson, Christian Jamtheim
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 29
  • [29] Synthetic computed tomography generation for abdominal adaptive radiotherapy using low-field magnetic resonance imaging
    Hernandez, Armando Garcia
    Fau, Pierre
    Wojak, Julien
    Mailleux, Hugues
    Benkreira, Mohamed
    Rapacchi, Stanislas
    Adel, Mouloud
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 25
  • [30] Clinical experience using Delta 4 phantom for pretreatment patient-specific quality assurance in modern radiotherapy
    Srivastava, R. P.
    De Wagter, C.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (02) : 210 - 214