Analysis of Conducted Disturbance via Current Transformer Due to Switch Operation of GIS Disconnector in UHV Substation

被引:3
|
作者
Zhao, Jun [1 ]
Chen, Weijiang [2 ]
Li, Kejie [3 ]
Teng, Zihan [1 ]
Li, Ni [1 ]
Wen, Tao [3 ]
Fan, Xing [4 ]
机构
[1] China Elect Power Res Inst, State Key Lab Power Grid Environm Protect, Beijing, Peoples R China
[2] State Grid Corp China, Beijing, Peoples R China
[3] Hefei Univ Technol, Sch Elect Engn & Automat, Hefei, Peoples R China
[4] Xi An Jiao Tong Univ, Sch Elect Engn, Xian, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Integrated circuit modeling; Windings; Substations; Current measurement; Insulators; Soil; Impedance; Conducted disturbance; current transformer; switch operation; simulation; UHV substation;
D O I
10.17775/CSEEJPES.2021.05580
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The characteristics of conducted disturbances via current transformer (CT) caused by switch operations in 1000 kV UHV substations are studied in this paper. Since the broad-band circuit models might have limitations on the stability and accuracy for CT conducted disturbance simulation, a frequency-domain simulation method without circuit synthesis is proposed based on VFTC spectrum and CT transfer characteristics. To improve VFTC simulation accuracy, both the bushing radiation loss and frequency-dependent earth impedance are taken into consideration. Transfer characteristics of three types of windings for the 1000 kV GIS CT are ingeniously measured from a combination of fast and slow impulse tests. Through conducted disturbances simulations in UHV Wuhu substation, bushing radiation loss is found to have a suppression effect on the high-frequency response but the effect of frequency-dependent earth impedance can be ignored. As a result, the maximum amplitude of 84.5 A for the conducted disturbance is obtained, thus a fast damped oscillatory wave immunity test with no lower than Level 4 from IEC standard is suggested to test the anti-interference performance of the secondary equipment in UHV substation.
引用
收藏
页码:1227 / 1234
页数:8
相关论文
共 6 条
  • [1] Analysis and Simulated Experiment for Port Disturbance Voltage Due to Switching Operation in GIS Substation
    Wu H.
    Jiao C.
    Cui X.
    Liu X.
    Ji J.
    Gaodianya Jishu/High Voltage Engineering, 2017, 43 (10): : 3387 - 3395
  • [2] Fast Transient Overvoltage Analysis in Current Transformers due to Disconnector Switching Operation
    Gadotti, Filipe R.
    Cabral, Sergio H. L.
    Schuartz, Felipe M.
    2022 7TH INTERNATIONAL ADVANCED RESEARCH WORKSHOP ON TRANSFORMERS (ARWTR 2022), 2022, : 58 - 63
  • [3] Numerical calculation of grounding current through Capacitive Voltage Transformer due to substation switching operation
    Liu, Lei
    Cui, Xiang
    Qi, Lei
    Li, Lin
    Gao, Changzheng
    2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1-3, PROCEEDINGS, 2006, : 518 - 521
  • [4] Frequency domain algorithm in the whole process simulation from VFTO to its conducted disturbance via voltage transformer in GIS substations
    Zhao, Jun
    Chen, Weijiang
    Li, Kejie
    Wan, Baoquan
    Zhang, Jiangong
    Wen, Tao
    Zhang, Xiaoli
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 209
  • [5] Operation analysis of spare power automatic switch device after 110 kV circuit breaker manually opening in Luojiazhuang transformer substation
    Qi, Wan-Li
    Zheng, Guo-Xiang
    Han, Yong-Jun
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (05): : 141 - 142
  • [6] Measurement and Analysis of Electromagnetic Disturbance at the Secondary Side of Electronic Voltage Transformer Due to Switching Operations Via a 6 kv Switchgear
    Wu, Yan
    Hu, Yi-fan
    He, Ri
    Jiao, Chong-qing
    2017 IEEE 5TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC-BEIJING), 2017,