Batch Production of High-Quality Graphene Grids for Cryo-EM: Cryo-EM Structure of Methylococcus capsulatus Soluble Methane Monooxygenase Hydroxylase

被引:4
|
作者
Ahn, Eungjin [1 ]
Kim, Byungchul [1 ]
Park, Soyoung [1 ,2 ]
Erwin, Amanda L. [3 ,4 ]
Sung, Suk Hyun [5 ]
Hovden, Robert [5 ]
Mosalaganti, Shyamal [3 ,4 ]
Cho, Uhn-Soo [1 ]
机构
[1] Univ Michigan, Dept Biol Chem, Ann Arbor, MI 48109 USA
[2] Seoul Natl Univ Sci & Technol, Dept Fine Chem, Seoul 139743, South Korea
[3] Univ Michigan, Dept Cell & Dev Biol, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Life Sci Inst, Ann Arbor, MI 48109 USA
[5] Univ Michigan, Dept Mat Sci & Engn, Ann Arbor, MI 48105 USA
关键词
Cryogenic electron microscopy; Single particle analysis; Graphene grid; M; caps sMMOH; Tomography; CRYOELECTRON MICROSCOPY; ELECTRON-MICROSCOPY; CRYSTAL-STRUCTURES; PROTEIN COMPLEXES; AFFINITY GRIDS; COMPONENT; OXIDATION; IMPLEMENTATION; VISUALIZATION; STRENGTH;
D O I
10.1021/acsnano.3c00463
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Cryogenic electron microscopy (cryo-EM) has become a widely used tool for determining the protein structure. Despite recent technical advances, sample preparation remains a major bottleneck for several reasons, including protein denaturation at the air-water interface, the presence of preferred orientations, nonuniform ice layers, etc. Graphene, a two-dimensional allotrope of carbon consisting of a single atomic layer, has recently gained attention as a near-ideal support film for cryo-EM that can overcome these challenges because of its superior properties, including mechanical strength and electrical conductivity. Here, we introduce a reliable, easily implemented, and reproducible method to produce 36 graphene-coated grids within 1.5 days. To demonstrate their practical application, we determined the cryo-EM structure of Methylococcus capsulatus soluble methane monooxygenase hydroxylase (sMMOH) at resolutions of 2.9 and 2.5 angstrom using Quantifoil and graphene-coated grids, respectively. We found that the graphene-coated grid has several advantages, including a smaller amount of protein required and avoiding protein denaturation at the air-water interface. By comparing the cryo-EM structure of sMMOH with its crystal structure, we identified subtle yet significant geometrical changes at the nonheme diiron center, which may better indicate the active site configuration of sMMOH in the resting/oxidized state.
引用
收藏
页码:6011 / 6022
页数:12
相关论文
共 50 条
  • [41] Rapid RNA structure determination through cryo-EM, high-throughput biochemistry, and computational modeling
    Kappel, Kalli
    Zhang, Kaiming
    Su, Zhaoming
    Pintilie, Grigore
    Chiu, Wah
    Das, Rhiju
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [42] Structure of IP3R channel: high-resolution insights from cryo-EM
    Baker, Mariah R.
    Fan, Guizhen
    Serysheva, Irina I.
    CURRENT OPINION IN STRUCTURAL BIOLOGY, 2017, 46 : 38 - 47
  • [43] Deep learning-based local quality estimation for protein structure models from cryo-EM maps
    Terashi, Genki
    Wang, Xiao
    Subramaniya, Sai Raghavendra Maddhuri Venkata
    Tesmer, John J.
    Kihara, Daisuke
    BIOPHYSICAL JOURNAL, 2022, 121 (03) : 129 - 129
  • [44] A Designed Imaging Scaffold Breaks the Barrier to High-Resolution Structure Determination of Small Proteins by Cryo-EM
    Castells-Graells, Roger
    Yeates, Todd O.
    PROTEIN SCIENCE, 2024, 33 : 54 - 54
  • [45] High-resolution structure determination of sub-100 kDa complexes using conventional cryo-EM
    Herzik, Mark A., Jr.
    Wu, Mengyu
    Lander, Gabriel C.
    NATURE COMMUNICATIONS, 2019, 10 (1)
  • [46] High-resolution cryo-EM of a small protein complex: The structure of the human CDK-activating kinase
    Greber, Basil J.
    STRUCTURE, 2024, 32 (04) : 380 - 392
  • [47] High-resolution cryo-EM structure of the junction region of the native cardiac thin filament in relaxed state
    Risi, Cristina M.
    Belknap, Betty
    White, Howard D.
    Dryden, Kelly
    Pinto, Jose R.
    Chase, P. Bryant
    Galkin, Vitold E.
    PNAS NEXUS, 2023, 2 (01):
  • [48] In situ and high-resolution cryo-EM structure of a bacterial type VI secretion system membrane complex
    Rapisarda, Chiara
    Cherrak, Yassine
    Kooger, Romain
    Schmidt, Victoria
    Pellarins, Riccardo
    Logger, Laureen
    Cascales, Eric
    Pilhofer, Martin
    Durand, Eric
    Fronzes, Remi
    EMBO JOURNAL, 2019, 38 (10):
  • [49] Cryo-EM structure of the open high-conductance Ca2+-activated K+ channel
    Xiao Tao
    Richard K. Hite
    Roderick MacKinnon
    Nature, 2017, 541 : 46 - 51
  • [50] Novel Designed Rigidified Imaging Scaffolds For High-Resolution Structure Determination Of Small Proteins With Cryo-EM
    Graells, Roger Castells
    Meador, Kyle
    Gee, Morgan
    Yeates, Todd
    Cannon, Kevin
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2022, 78 : A43 - A43