Study on smoke blocking and thermal radiation attenuation by water curtain in tunnel fire

被引:4
|
作者
Chen, Yinuo [1 ,2 ]
Jia, Jinzhang [1 ,2 ]
Che, Guangbo [1 ,2 ,3 ]
Zhu, Zhiheng [1 ,2 ]
Shen, Zhiyuan [1 ,2 ]
Wu, Yumo [1 ,2 ]
机构
[1] Liaoning Tech Univ, Sch Safety Sci & Engn, Fuxin 123000, Liaoning, Peoples R China
[2] Minist Educ, Key Lab MineThermal Disaster & Prevent, Huludao 125000, Liaoning, Peoples R China
[3] Jilin Normal Univ, Minist Educ, Key Lab Preparat & Applicat Environm Friendly Mat, Changchun 130103, Peoples R China
来源
SCIENTIFIC REPORTS | 2023年 / 13卷 / 01期
基金
中国国家自然科学基金;
关键词
MIST; VELOCITY; SPRAY; TESTS;
D O I
10.1038/s41598-023-27437-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A 1:10 scale model tunnel with a length, height and width of 9 m, 0.6 m and 0.8 m, respectively, was set up in this paper. A water curtain system was installed in the model to investigate the effect of water curtain systems on smoke flow and heat propagation. A reduced-scale experimental and theoretical study was carried out by varying the heat release rate of the fire source, the water curtain pressure, and the number of water curtain rows. A series of tests were carried out for various setups to quantify each mechanism of interaction between the water mist and hot smoke, to propose a method for qualitatively analysing water curtain systems blocking the propagation of heat radiation and the flow of smoke from combustion, and to propose a method for predicting heat fluxes. The study found that the pressure of the water curtain, the number of rows, and the heat release rate of the fire source all had an effect on the smoke blocking effect of the water curtain system. This effect decreased as the heat release rate of the fire source increased and increased significantly with the pressure of the water curtain and the number of rows. The smoke blocking effect was quantified using conservation of momentum by establishing a dimensionless parameter R to represent the ratio of water curtain momentum to smoke momentum, as well as the ratio of heat flux before and after the water curtain to represent the smoke blocking capacity delta of the water curtain. The smoke blockage rate delta ranges between 40 and 75%, and the smoke blockage rate increases as the momentum R increases. Finally, in tunnel fires, a predictive model for the attenuation of heat radiation by water curtains has been developed, providing theoretical support for the quantitative study of the smoke and thermal blockage effects of water curtains, which is beneficial to the protection of human life in confined spaces.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Study on smoke blocking and thermal radiation attenuation by water curtain in tunnel fire
    Yinuo Chen
    Jinzhang Jia
    Guangbo Che
    Zhiheng Zhu
    Zhiyuan Shen
    Yumo Wu
    Scientific Reports, 13 (1)
  • [2] Numerical study of air curtain systems for blocking smoke in tunnel fires
    Jung, Uk-Hee
    Kim, Sung
    Yang, Sang-Ho
    Kim, Jin-Hyuk
    Choi, Young-Seok
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2016, 30 (11) : 4961 - 4969
  • [3] Numerical study of air curtain systems for blocking smoke in tunnel fires
    Uk-Hee Jung
    Sung Kim
    Sang-Ho Yang
    Jin-Hyuk Kim
    Young-Seok Choi
    Journal of Mechanical Science and Technology, 2016, 30 : 4961 - 4969
  • [4] Experimental study of water sprays for the attenuation of fire thermal radiation
    Dembele, S
    Wen, JX
    Sacadura, JF
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2001, 123 (03): : 534 - 543
  • [5] Effectiveness of Smoke Confinement of Air Curtain in Tunnel Fire
    Gao, Dongli
    Li, Tao
    Chen, Zinan
    You, Shuhang
    Wang, Zhongkuan
    Wang, Kaihong
    Lin, Peng
    Mei, Xiujuan
    FIRE TECHNOLOGY, 2020, 56 (05) : 2283 - 2314
  • [6] Effectiveness of Smoke Confinement of Air Curtain in Tunnel Fire
    Dongli Gao
    Tao Li
    Xiujuan Mei
    Zinan Chen
    Shuhang You
    Zhongkuan Wang
    Kaihong Wang
    Peng Lin
    Fire Technology, 2020, 56 : 2283 - 2314
  • [7] Large eddy simulation of smoke blocking by water sprays in a tunnel fire
    Nishino, Ryo
    Ren, Ning
    Noda, Yuki
    Tanaka, Futoshi
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2022, 121
  • [8] Fire control and self-extinguishment by blocking smoke flow with water spray in a tunnel fire
    Tanaka, Futoshi
    Harada, Naoki
    Yamaoka, Shohei
    Moinuddin, Khalid A. M.
    FIRE SAFETY JOURNAL, 2024, 142
  • [9] Experimental study on fire smoke control using water mist curtain in channel
    Wang, Zhigang
    Wang, Xishi
    Huang, Yanqing
    Tao, Changfa
    Zhang, Heping
    JOURNAL OF HAZARDOUS MATERIALS, 2018, 342 : 231 - 241
  • [10] Research on the application mechanism of water mist curtain smoke blocking and heat blocking in tunnels
    Zhong, Wei
    Zhang, Zhanming
    Wu, Yinghao
    Gao, Zihe
    INDOOR AND BUILT ENVIRONMENT, 2025, 34 (02) : 330 - 354