Rapid Detection of Hepatitis A Virus in Foods Using a Bioluminescent Assay in Real-Time (BART) and Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Technology

被引:15
作者
Wu, Ruiqin [1 ,2 ]
Meng, Baozhong [3 ]
Corredig, Milena [1 ]
Griffiths, Mansel W. W. [1 ,2 ]
机构
[1] Univ Guelph, Dept Food Sci, 50 Stone Rd East, Guelph, ON N1G 2W1, Canada
[2] Canadian Res Inst Food Safety, 43 McGilvray St, Guelph, ON N1G 2W1, Canada
[3] Univ Guelph, Dept Mol & Cellular Biol, 50 Stone Rd East, Guelph, ON N1G 2W1, Canada
关键词
Hepatitis A virus; Detection; RT-LAMP-BART; Food; QUANTITATIVE DETECTION; COLORIMETRIC DETECTION; VISUAL DETECTION; ENTERIC VIRUSES; PCR; PATHOGENS; CHIP; GENE; DNA; IDENTIFICATION;
D O I
10.1007/s12560-022-09548-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Foodborne hepatitis A infections have been considered as a major threat for public health worldwide. Increased incidences of hepatitis A virus (HAV) infection has been associated with growing global trade of food products. Rapid and sensitive detection of HAV in foods is very essential for investigating the outbreaks. Real-time RT-PCR has been most widely used for the detection of HAV by far. However, the technology relies on fluorescence determination of the amplicon and requires sophisticated, high-cost instruments and trained personnel, limiting its use in low resource settings. In this study, a robust, affordable, and simple assay, reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay in combination with a bioluminescence-based determination of amplification in real-time (BART), was developed for the detection of HAV in different food matrices, including green onion, strawberry, mussel, and milk. The efficiencies of a one-step RT-LAMP-BART and a two-step RT-LAMP-BART were investigated for the detection of HAV in different food matrices and was compared with that of real-time RT-PCR. The sensitivity of the RT-LAMP-BART assay was significantly affected by Mg2+ concentration (P < 0.05), in addition to primer quality. The optimal Mg2+ concentration was 2 mM for one-step RT-LAMP-BART and 4 mM for two-step RT-LAMP-BART. Compared with cartridge-purified primers, HPLC-purified primers could greatly improve the sensitivity of the RT-LAMP-BART assay (P < 0.05). For detecting HAV in different food matrices, the performance of two-step RT-LAMP-BART was comparable with that of real-time RT-PCR and was better than that of one-step RT-LAMP-BART. The detection limit of the two-step RT-LAMP-BART for HAV in green onion, strawberry, mussel, and milk was 8.3 x 10(0) PFU/15 g, 8.3 x 10(1) PFU/50 g, 8.3 x 10(0) PFU/5 g, and 8.3 x 10(0) PFU/40 mL, respectively. The developed RT-LAMP-BART was an effective, simple, sensitive, and robust method for foodborne HAV detection.
引用
收藏
页码:144 / 157
页数:14
相关论文
共 95 条
[21]   Loop-Mediated Isothermal Amplification (LAMP): Methods for Plant Species Identification in Food [J].
Focke, Felix ;
Haase, Ilka ;
Fischer, Markus .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2013, 61 (12) :2943-2949
[22]   Robustness of a loop-mediated isothermal amplification reaction for diagnostic applications [J].
Francois, Patrice ;
Tangomo, Manuela ;
Hibbs, Jonathan ;
Bonetti, Eve-Julie ;
Boehme, Catharina C. ;
Notomi, Tsugunori ;
Perkins, Mark D. ;
Schrenzel, Jacques .
FEMS IMMUNOLOGY AND MEDICAL MICROBIOLOGY, 2011, 62 (01) :41-48
[23]   Development and optimization of a group-specific loop-mediated isothermal amplification (LAMP) assay for the detection of patulin-producing Penicillium species [J].
Frisch, Lisa M. ;
Niessen, Ludwig .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2019, 298 :20-30
[24]   Loop-Mediated Amplification Accelerated by Stem Primers [J].
Gandelman, Olga ;
Jackson, Rebecca ;
Kiddle, Guy ;
Tisi, Laurence .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2011, 12 (12) :9108-9124
[25]   Novel Bioluminescent Quantitative Detection of Nucleic Acid Amplification in Real-Time [J].
Gandelman, Olga A. ;
Church, Vicki L. ;
Moore, Cathy A. ;
Kiddle, Guy ;
Carne, Christopher A. ;
Parmar, Surendra ;
Jalal, Hamid ;
Tisi, Laurence C. ;
Murray, James A. H. .
PLOS ONE, 2010, 5 (11)
[26]   Limitations of TaqMan PCR for detecting divergent viral pathogens illustrated by hepatitis A, B, C, and E viruses and human immunodeficiency virus [J].
Gardner, SN ;
Kuczmarski, TA ;
Vitalis, EA ;
Slezak, TR .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (06) :2417-2427
[27]   Rapid detection of pork using alkaline lysis- Loop Mediated Isothermal Amplification (AL-LAMP) technique [J].
Girish, P. S. ;
Barbuddhe, S. B. ;
Kumari, Aparana ;
Rawool, Deepak B. ;
Karabasanavar, Nagappa S. ;
Muthukumar, M. ;
Vaithiyanathan, S. .
FOOD CONTROL, 2020, 110
[28]   Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxy naphthol blue [J].
Goto, Motoki ;
Honda, Eiichi ;
Ogura, Atsuo ;
Nomoto, Akio ;
Hanaki, Ken-Ichi .
BIOTECHNIQUES, 2009, 46 (03) :167-+
[29]   Development of an extraction and concentration procedure and comparison of RT-PCR primer systems for the detection of hepatitis A virus and norovirus GII in green onions [J].
Guevremont, Evelyne ;
Brassard, Julie ;
Houde, Alain ;
Simard, Carole ;
Trottier, Yvon-Louis .
JOURNAL OF VIROLOGICAL METHODS, 2006, 134 (1-2) :130-135
[30]   Bioluminescent detection of isothermal DNA amplification in microfluidic generated droplets and artificial cells [J].
Hardinge, Patrick ;
Baxani, Divesh K. ;
McCloy, Thomas ;
Murray, James A. H. ;
Castell, Oliver K. .
SCIENTIFIC REPORTS, 2020, 10 (01)