Rapid Detection of Hepatitis A Virus in Foods Using a Bioluminescent Assay in Real-Time (BART) and Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Technology

被引:14
作者
Wu, Ruiqin [1 ,2 ]
Meng, Baozhong [3 ]
Corredig, Milena [1 ]
Griffiths, Mansel W. W. [1 ,2 ]
机构
[1] Univ Guelph, Dept Food Sci, 50 Stone Rd East, Guelph, ON N1G 2W1, Canada
[2] Canadian Res Inst Food Safety, 43 McGilvray St, Guelph, ON N1G 2W1, Canada
[3] Univ Guelph, Dept Mol & Cellular Biol, 50 Stone Rd East, Guelph, ON N1G 2W1, Canada
关键词
Hepatitis A virus; Detection; RT-LAMP-BART; Food; QUANTITATIVE DETECTION; COLORIMETRIC DETECTION; VISUAL DETECTION; ENTERIC VIRUSES; PCR; PATHOGENS; CHIP; GENE; DNA; IDENTIFICATION;
D O I
10.1007/s12560-022-09548-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Foodborne hepatitis A infections have been considered as a major threat for public health worldwide. Increased incidences of hepatitis A virus (HAV) infection has been associated with growing global trade of food products. Rapid and sensitive detection of HAV in foods is very essential for investigating the outbreaks. Real-time RT-PCR has been most widely used for the detection of HAV by far. However, the technology relies on fluorescence determination of the amplicon and requires sophisticated, high-cost instruments and trained personnel, limiting its use in low resource settings. In this study, a robust, affordable, and simple assay, reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay in combination with a bioluminescence-based determination of amplification in real-time (BART), was developed for the detection of HAV in different food matrices, including green onion, strawberry, mussel, and milk. The efficiencies of a one-step RT-LAMP-BART and a two-step RT-LAMP-BART were investigated for the detection of HAV in different food matrices and was compared with that of real-time RT-PCR. The sensitivity of the RT-LAMP-BART assay was significantly affected by Mg2+ concentration (P < 0.05), in addition to primer quality. The optimal Mg2+ concentration was 2 mM for one-step RT-LAMP-BART and 4 mM for two-step RT-LAMP-BART. Compared with cartridge-purified primers, HPLC-purified primers could greatly improve the sensitivity of the RT-LAMP-BART assay (P < 0.05). For detecting HAV in different food matrices, the performance of two-step RT-LAMP-BART was comparable with that of real-time RT-PCR and was better than that of one-step RT-LAMP-BART. The detection limit of the two-step RT-LAMP-BART for HAV in green onion, strawberry, mussel, and milk was 8.3 x 10(0) PFU/15 g, 8.3 x 10(1) PFU/50 g, 8.3 x 10(0) PFU/5 g, and 8.3 x 10(0) PFU/40 mL, respectively. The developed RT-LAMP-BART was an effective, simple, sensitive, and robust method for foodborne HAV detection.
引用
收藏
页码:144 / 157
页数:14
相关论文
共 95 条
[1]   Evaluation of a loop-mediated isothermal amplification (LAMP) method for rapid on-site detection of horse meat [J].
Aartse, Aafke ;
Scholtens, Ingrid M. J. ;
van der A, Hans J. G. ;
Boersma-Greve, Monique M. ;
Prins, Theo W. ;
van Ginkel, Leen A. ;
Kok, Esther J. ;
Bovee, Toine F. H. .
FOOD CONTROL, 2017, 81 :9-15
[2]   Development of Loop-Mediated Isothermal Amplification (LAMP) Assay for Rapid and Sensitive Identification of Ostrich Meat [J].
Abdulmawjood, Amir ;
Grabowski, Nils ;
Fohler, Svenja ;
Kittler, Sophie ;
Nagengast, Helga ;
Klein, Guenter .
PLOS ONE, 2014, 9 (06)
[3]   A CCD-based fluorescence imaging system for real-time loop-mediated isothermal amplification-based rapid and sensitive detection of waterborne pathogens on microchips [J].
Ahmad, Farhan ;
Seyrig, Gregoire ;
Tourlousse, Dieter M. ;
Stedtfeld, Robert D. ;
Tiedje, James M. ;
Hashsham, Syed A. .
BIOMEDICAL MICRODEVICES, 2011, 13 (05) :929-937
[4]   A molecular test based on RT-LAMP for rapid, sensitive and inexpensive colorimetric detection of SARS-CoV-2 in clinical samples [J].
Amaral, Catarina ;
Antunes, Wilson ;
Moe, Elin ;
Duarte, Americo G. ;
Lima, Luis M. P. ;
Santos, Cristiana ;
Gomes, Ines L. ;
Afonso, Goncalo S. ;
Vieira, Ricardo ;
Teles, Helena Sofia S. ;
Reis, Marisa S. ;
Ramalho da Silva, Manuel A. ;
Henriques, Ana Margarida ;
Fevereiro, Miguel ;
Ventura, M. Rita ;
Serrano, Monica ;
Pimentel, Catarina .
SCIENTIFIC REPORTS, 2021, 11 (01)
[5]  
[Anonymous], 2020, Food Safety
[6]  
Bhaskar SV, 2017, FOOD SAFETY IN THE 21ST CENTURY: PUBLIC HEALTH PERSPECTIVE, P3, DOI 10.1016/B978-0-12-801773-9.00001-7
[7]  
Biolegio, OL PUR
[8]   Foodborne viruses: Detection, risk assessment, and control options in food processing [J].
Bosch, Albert ;
Gkogka, Elissavet ;
Le Guyader, Francoise S. ;
Loisy-Hamon, Fabienne ;
Lee, Alvin ;
van Lieshout, Lilou ;
Marthi, Balkumar ;
Myrmel, Mette ;
Sansom, Annette ;
Schultz, Anna Charlotte ;
Winkler, Anett ;
Zuber, Sophie ;
Phister, Trevor .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2018, 285 :110-128
[9]   Procedure for rapid concentration and detection of enteric viruses from berries and vegetables [J].
Butot, S. ;
Putallaz, T. ;
Sanchez, G. .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2007, 73 (01) :186-192
[10]   Detection of viable but nonculturable Vibrio parahaemolyticus in shrimp samples using improved real-time PCR and real-time LAMP methods [J].
Cao, Xiao ;
Zhao, Lichao ;
Zhang, Jingfeng ;
Chen, Xun ;
Shi, Lei ;
Fang, Xiang ;
Xie, Hui ;
Chang, Yanlei ;
Wang, Li .
FOOD CONTROL, 2019, 103 :145-152