Comparison of two swept-source optical coherence tomography devices, a Scheimpflug camera system and a ray-tracing aberrometer in the measurement of corneal power in patients with cataract

被引:3
作者
Ma, Shan [1 ,2 ,3 ,4 ]
Gao, Rongyu [3 ,4 ]
Sun, Jing [1 ,2 ]
Yang, Jun [1 ,2 ]
Wen, Kai [1 ,2 ]
Chen, Xiteng [1 ,2 ]
Zhao, Fangyu [1 ,2 ]
Xu, Xinyan [3 ,4 ]
Tian, Fang [1 ,2 ]
机构
[1] Tianjin Med Univ, Eye Inst, Natl Clin Res Ctr Ocular Dis, Eye Hosp,Tianjin Key Lab Retinal Funct & Dis,Tianj, Tianjin 300380, Peoples R China
[2] Tianjin Med Univ, Eye Hosp, Sch Optometry, Tianjin 300380, Peoples R China
[3] Weifang Eye Hosp, Natl Key Clin Specialty, Zhengda Guangming Eye Grp, Weifang 261000, Peoples R China
[4] Weifang Eye Inst, Weifang 261000, Peoples R China
关键词
Corneal curvature; IOLMaster; 700; CASIA2; Pentacam; iTrace; Astigmatic vector analysis; AGREEMENT; REPEATABILITY; BIOMETRY;
D O I
10.1007/s00417-023-06348-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo assess the differences and similarities in the corneal curvature obtained by two swept-source optical coherence tomography (SS-OCT) devices, Scheimpflug imaging system and one ray tracing aberrometer in patients with cataracts. Moreover, this study aimed to compare the differences in posterior corneal (PK), total corneal (TK) and true net power (TNP) measurements among the IOLMaster 700, CASIA2, and Pentacam.MethodsA total of 200 eyes of 200 patients (116 female, 58%) were enrolled in this study, with a mean age of 65.9 +/- 9.5 years. The flattest (Kf), steepest (Ks), and mean cornal powers (Km), J0, and J45 were obtained using two SS-OCT-based biometric devices, one rotating camera system and one ray-tracing aberrometer. The PK, TK and TNP values were also measured using these devices. To evaluate the differences and similarities between the devicves, the Friedman test, Pearson correlation coefficient (r), intraclass coefficient correlation (ICC) and Bland-Altman plots with 95% limits of agreement (LoA) were used, and boxplots and stacked histograms were generated to describe the distributions of the data.ResultsThere were no significant differences between the IOLMaster 700 and Pentacam for any of the keratometry values. Additionally, there were no significant differences between the IOLMaster 700 and iTrace in evaluating J0 and J45. Bland-Altman plots revealed relatively wide LoA widths, almost larger than 1 diopter for the keratometry values and almost larger than 0.5 diopter for J0 and J45 values among the four devices. In terms of PK and TK values, significant differences and low ICCs were found among the three devices.ConclusionsAlthough strong correlations and good agreement were found among the IOLMaster700, CASIA2, Pentacam and iTrace for Kf, Ks, Km and J0, J45, it seems that the measurements should not be used interchangeably because of the wide LoA widths and the presence of significant differences among the devices. Similarly, due to significant differences and low ICCs, the PK, TK and TNP values obtained by IOLMaster 700, CASIA2, and Pentacam should not be used interchangeably.
引用
收藏
页码:1567 / 1578
页数:12
相关论文
共 28 条
[1]   User's guide to correlation coefficients [J].
Akoglu, Haldun .
TURKISH JOURNAL OF EMERGENCY MEDICINE, 2018, 18 (03) :91-93
[2]   Comparison of Anterior Corneal Aberrometry, Keratometry and Pupil Size with Scheimpflug Tomography and Ray Tracing Aberrometer [J].
Ashena, Zahra ;
Gallagher, Sean ;
Naveed, Hasan ;
Spalton, David J. ;
Nanavaty, Mayank A. .
VISION, 2022, 6 (01)
[3]   Agreement in anterior segment measurements between swept-source and Scheimpflug-based optical biometries in keratoconic eyes: a pilot study [J].
Chalkiadaki, Evangelia ;
Gartaganis, Panos S. ;
Ntravalias, Thomas ;
Giannakis, Ioannis ;
Manousakis, Evangelos ;
Karmiris, Efthymios .
THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2022, 14
[4]   How Can We Improve Toric Intraocular Lens Calculation Methods? Current Insights [J].
Ferreira, Tiago B. ;
Ribeiro, Filomena .
CLINICAL OPHTHALMOLOGY, 2020, 14 :1899-1908
[5]   Ocular biometric measurements in cataract surgery candidates in Portugal [J].
Ferreira, Tiago B. ;
Hoffer, Kenneth J. ;
Ribeiro, Filomena ;
Ribeiro, Paulo ;
O'Neill, Joao G. .
PLOS ONE, 2017, 12 (10)
[6]   Analysis of keratometric measurements in accordance with axial length in an aged population [J].
Han, Sung Uk ;
Ryu, Soyoung ;
Jung, Hyunjean ;
Ahn, Hyunmin ;
Kim, Sangyeop ;
Jun, Ikhyun ;
Seo, Kyoung Yul ;
Kim, Tae-im .
SCIENTIFIC REPORTS, 2022, 12 (01)
[7]   Analysis of biometry and prevalence data for corneal astigmatism in 23 239 eyes [J].
Hoffmann, Peter Christian ;
Huetz, Werner W. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (09) :1479-1485
[8]   Agreement of corneal curvature and central cornea thickness obtained from a swept-source OCT and Pentacam in ectopia lentis patients [J].
Jin, Guang-Ming ;
Xiao, Bing ;
Zhou, Yi-Jing ;
Wang, Yi-Yao ;
Li, Xue-Pei ;
Zheng, Dan-Ying .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (08) :1244-1249
[9]   Current Developments in Corneal Topography and Tomography [J].
Kanclerz, Piotr ;
Khoramnia, Ramin ;
Wang, Xiaogang .
DIAGNOSTICS, 2021, 11 (08)
[10]  
Koch DD, 2021, J CATARACT REFR SURG, V47, P100, DOI 10.1097/j.jcrs.0000000000000428