Effect of polishing and denture cleansers on the surface roughness of new-generation denture base materials and their color change after cleansing

被引:2
|
作者
Cakmak, Guelce [1 ]
Hess, Julia Anouk [1 ]
Donmez, Mustafa Borga [1 ,2 ,9 ]
Yilmaz, Deniz [3 ]
Alhotan, Abdulaziz [4 ]
Schimmel, Martin [1 ,5 ]
Peutzfeldt, Anne [6 ,7 ]
Yilmaz, Burak [1 ,6 ,8 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[2] Istinye Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
[3] Alanya Alaaddin Keykubat Univ, Fac Dent, Dept Prosthodont, Antalya, Turkiye
[4] King Saud Univ, Coll Appl Med Sci, Dent Hlth Dept, Riyadh, Saudi Arabia
[5] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
[6] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[7] Univ Copenhagen, Fac Hlth & Med Sci, Dept Odontol, Copenhagen, Denmark
[8] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH USA
[9] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3007 Bern, Switzerland
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2024年 / 33卷 / 08期
关键词
additive manufacturing; chemical disinfection; color change; denture base; surface roughness; CHEMICAL DISINFECTION; FLEXURAL STRENGTH; PMMA; TOPOGRAPHY; STABILITY;
D O I
10.1111/jopr.13755
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the effect of polishing and denture cleansers on the surface roughness (Ra) of new-generation denture basematerials that are additively, subtractively, and conventionally fabricated, while also assessing their color change after cleansing. Material and Methods: One hundred and fifty disk-shaped specimens (O10 x 2 mm) were prepared from five denture base materials (one subtractively manufactured nanographene-reinforced prepolymerized polymethylmethacrylate (PMMA) (SM-GC), one subtractively manufactured prepolymerized PMMA (SM-PM), two additively manufactured denture base resins (AM-DT and AM-ND), and one heat-polymerized PMMA (CV) (n = 30). The R-a of the specimens was measured before and after conventional laboratory polishing, while color coordinates were measured after polishing. Specimens were then divided into three subgroups based on the denture cleanser: distilled water, 1% sodium hypochlorite (NaOCl), and effervescent tablet (n = 10). The R-a and color coordinates were remeasured after nine cleansing cycles over a period of 20 days. The CIEDE2000 formula was used to calculate the color differences (Delta E-00). Two-way analysis of variance (ANOVA) was used to analyze the R-a values before (n = 30) and after (n = 10) cleansing, while repeated measures ANOVA was used to analyze the R-a of material-time point pairs within each denture cleanser (n = 10). Delta E-00 data after denture cleansing was also analyzed by using two-way ANOVA (n = 10) (a = 0.05). Results: Before polishing, Ra varied significantly among the materials. SM-GC and SM-PM had the lowest and AM-ND the highest Ra values (P < 0.001). Polishing significantly reduced R-a of all materials (P < 0.001), and after polishing, Ra differences among materials were nonsignificant (P >= 0.072). Regardless of the denture cleanser, the R-a of AM-DT, AM-ND, and CV was the highest before polishing when different time points were considered (P < 0.001). After cleansing, AM-ND had the highest R-a of all the materials, regardless of the cleanser (P <= 0.017). AM-DT had higher R-a than SM-PM when distilled water (P = 0.040) and higher R-a than SM-GC, SM-PM, and CV when NaOCl was used (P < 0.001). The type of cleanser significantly influenced the R-a of AM-DT, AM-ND, and CV. For AM-DT, NaOCl led to the highest R-a and the tablet led to the lowest R-a (P <= 0.042), while for AM-ND, distilled water led to the lowest R-a (P <= 0.024). For CV, the tablet led to lower R-a than distilled water (P = 0.009). Color change varied among the materials. When distilled water was used, SM-GC had higher Delta E-00 than SM-PM and AM-DT (P <= 0.034). When NaOCl was used, AM-ND had higher Delta E-00 than SM-GC, SM-PM, and AM-DT, while CV and SM-GC had higher Delta E-00 than SM-PM and AM-DT (P = 0.039). Finally, when the tablet was used, AM-ND and CV had the highest Delta E-00, while AM-DT had lower Delta E-00 than SM-GC (P = 0.015). Conclusions: The tested materials had unacceptable surface roughness (>0.2 mu m) before polishing. Roughness decreased significantly after polishing (<0.2 mu m). Denture cleansers did not significantly affect the surface roughness of the materials, and roughness remained clinically acceptable after cleansing (<0.2 mu m). Considering previously reported color thresholds, AM-ND and CV had unacceptable color change regardless of the denture cleanser, and the effervescent tablet led to perceptible, but acceptable color change for SM-GC, SM-PM, and AM-DT.
引用
收藏
页码:783 / 790
页数:8
相关论文
共 50 条
  • [31] Effect of beverages, denture cleanser and chlorhexidine gluconate on surface roughness of flexible denture base material: an in vitro study
    Saraf, Sneha
    Mishra, Sunil Kumar
    Agrawal, Benaiffer
    EUROPEAN ORAL RESEARCH, 2024, 58 (02) : 76 - 82
  • [32] Effect of thermocycling on the surface properties of CAD-CAM denture base materials after different surface treatments
    Atalay, Sevda
    Cakmak, Guelce
    Fonseca, Manrique
    Schimmel, Martin
    Yilmaz, Burak
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 121
  • [33] Flexural strength, surface roughness, and color stability of various CAD-CAM denture teeth materials
    Orgev, Ahmet
    Cakmak, Gulce
    Peng, Chin-chun
    Lavrentiadis, Grigoris
    Li, Rui
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [34] Surface roughness and stainability of CAD-CAM denture base materials after simulated brushing and coffee thermocycling
    Cakmak, Gulce
    Donmez, Mustafa Borga
    Atalay, Sevda
    de Paula, Marcella Silva
    Fonseca, Manrique
    Schimmel, Martin
    Yilmaz, Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (01) : 260 - 266
  • [35] Effect of Nanodiamond Addition on Flexural Strength, Impact Strength, and Surface Roughness of PMMA Denture Base
    Al-Harbi, Fahad A.
    Abdel-Halim, Mohamed S.
    Gad, Mohammed M.
    Fouda, Shaimaa M.
    Baba, Nadim Z.
    AlRumaih, Hamad S.
    Akhtar, Sultan
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (01): : E417 - E425
  • [36] Surface roughness of acrylic resins used for denture base after chemical disinfection: A systematic review and meta-analysis
    Florencio Costa, Rayanna Thayse
    Pellizzer, Eduardo Piza
    do Egito Vasconcelos, Belmiro Cavalcanti
    Luna Gomes, Jessica Marcela
    Araujo Lemos, Cleidiel Aparecido
    Dantas de Moraes, Sandra Lucia
    GERODONTOLOGY, 2021, 38 (03) : 242 - 251
  • [37] The Effects of Salivary pH on Color Stability and Surface Roughness of Different Denture Acrylic Resin Materials
    Alfadda, Sara A.
    Al-Otaibi, Hanan N.
    Al Shaalan, Nouf S.
    Al Qarni, Roba
    AlMutairi, Ree M.
    Al Taweel, Sara M.
    AlFouzan, Afnan
    BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS, 2020, 13 (03): : 1287 - 1294
  • [38] Influence of a new denture cleaning technique based on photolysis of H2O2 on the mechanical properties and color change of acrylic denture base resin
    Nakahara, Tatsuro
    Harada, Akio
    Yamada, Yasutomo
    Odashima, Yu
    Nakamura, Keisuke
    Inagaki, Ryoichi
    Kanno, Taro
    Sasaki, Keiichi
    Niwano, Yoshimi
    DENTAL MATERIALS JOURNAL, 2013, 32 (04) : 529 - 536
  • [39] Effect of surface roughness on the hydrophobicity of a denture-base acrylic resin and Candida albicans colonization
    de Foggi, Camila C.
    Machado, Ana L.
    Zamperini, Camila A.
    Fernandes, Darcy
    Wady, Amanda F.
    Vergani, Carlos E.
    JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2016, 7 (02) : 141 - 148
  • [40] The effect of mechanical and chemical polishing techniques on the surface roughness of heat-polymerized and visible light-polymerized acrylic denture base resins
    Al-Kheraif, Abdul Aziz Abdullah
    SAUDI DENTAL JOURNAL, 2014, 26 (02) : 56 - 62