Impacts of draw solutes on the fate of tetracycline in an osmotic membrane bioreactor: Role of the combination between membrane fouling and microorganisms

被引:8
|
作者
Lu, Yu-Xiang [1 ,2 ]
Yuan, Heyang [4 ]
Chand, Hameer [1 ]
Wu, You [1 ]
Yang, Yu-Li [1 ]
Liang, Heng [5 ]
Song, Hai-Liang [3 ]
机构
[1] Nanjing Normal Univ, Sch Environm, Nanjing 210023, Peoples R China
[2] Guangxi Normal Univ, Minist Educ, Key Lab Ecol Rare & Endangered Species & Environm, 15 Yucai Rd, Guilin 541004, Peoples R China
[3] Jiangsu Prov Engn Res Ctr Environm Risk Prevent &, Jiangsu Engn Lab Water & Soil Ecoremediat, Wenyuan Rd 1, Nanjing 210023, Peoples R China
[4] Temple Univ, Dept Civil & Environm Engn, Philadelphia, PA 19312 USA
[5] Harbin Inst Technol, State Key Lab Urban Water Resource & Environm, Harbin 150090, Peoples R China
基金
中国国家自然科学基金;
关键词
Osmotic membrane bioreactor; Tetracycline; Filtration; Biodegradation; Membrane fouling; SOLUBLE MICROBIAL PRODUCTS; WASTE-WATER; ANTIBIOTICS; PERFORMANCE; SMP; DEGRADATION; REJECTION; REMOVAL; SLUDGE;
D O I
10.1016/j.jhazmat.2023.132246
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Osmotic membrane bioreactors (OMBRs) are considered a suitable technology for treating wastewater containing tetracycline due to their high rejection and biodegradation efficiency. However, the impact of membrane fouling layer (i.e., chemical composition, microbial composition, and formation) on the filtration and biodegradation of tetracycline is still unclear. Herein, the effects of draw solute concentration and type on the formation of a membrane fouling layer for tetracycline filtration and its relationship with microbial activity were investigated. The results showed that over 99% of tetracycline was retained on the feed side by membrane rejection, and the fouling layer played an important role in tetracycline filtration. Specifically, membrane foulants resulted in a more hydrophilic membrane facilitating tetracycline filtration, while the tetracycline-degrading genera from the fouled membrane promoted tetracycline degradation. The structure equation model showed that tetracycline filtration dominated by electrostatic repulsion between tetracycline and the fouled membrane was more important than tetracycline degradation for tetracycline removal (path coefficient of 0.655 vs. 0.395). This study provided insights into the combined effect of membrane foulants and microorganisms on tetracycline removal.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Role and variations of supernatant compounds in submerged membrane bioreactor fouling
    Rojas, MEH
    Van Kaam, R
    Schetrite, S
    Albasi, C
    DESALINATION, 2005, 179 (1-3) : 95 - 107
  • [42] Relationships between mechanically induced hydrodynamics and membrane fouling in a novel rotating membrane bioreactor
    Jiang, Tao
    Zhang, Hanmin
    Yang, Fenglin
    Gao, Dawen
    Du, Hai
    DESALINATION AND WATER TREATMENT, 2013, 51 (13-15) : 2850 - 2861
  • [43] Impacts of sludge retention time on sludge characteristics and membrane fouling in a submerged anaerobic–oxic membrane bioreactor
    Xiaomei Zhang
    Xiuping Yue
    Zhiqiang Liu
    Qingqing Li
    Xiufu Hua
    Applied Microbiology and Biotechnology, 2015, 99 : 4893 - 4903
  • [44] Predicting membrane fouling in membrane bioreactor systems using viscosity: Impacts of environmental conditions and antifouling agents
    Sinahroy, Arindam
    Kim, Seung Hui
    Chung, Chong Min
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2024, 370
  • [45] Interaction mechanism between membrane biofouling and reverse solute diffusion in an osmotic membrane bioreactor
    Zhai, Si-Qi
    Nan, Jing
    Cai, Wen-Jun
    He, Xi-Wei
    Yang, Xiao-Li
    Yang, Yu-Li
    Song, Hai-Liang
    JOURNAL OF WATER PROCESS ENGINEERING, 2025, 71
  • [46] COMPARISON BETWEEN A MEMBRANE BIOREACTOR, A HYBRID MOVING BED BIOFILM REACTOR-MEMBRANE BIOREACTOR AND A PURE MOVING BED BIOFILM REACTOR-MEMBRANE BIOREACTOR ON MEMBRANE FOULING
    Leyva-Diaz, J. C.
    Martin-Pascual, J.
    Fenice, M.
    Munio, M. M.
    Poyatos, J. M.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2015, 16 (04): : 1502 - 1508
  • [47] Mitigation of solute buildup by using a biodegradable and reusable polyelectrolyte as a draw solute in an osmotic membrane bioreactor
    Yang, Yuli
    Song, Hailiang
    He, Zhen
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2019, 5 (01) : 19 - 27
  • [48] Fertilizer draw solution index in osmotic membrane bioreactor for simultaneous wastewater treatment and sustainable agriculture
    Nguyen Duc Viet
    Jang, Am
    CHEMOSPHERE, 2022, 296
  • [49] Role of extracellular polymeric substances (EPSs) in membrane fouling of membrane bioreactor coupled with worm reactor
    Tian, Yu
    Li, Zhipeng
    Chen, Lin
    Lu, Yaobin
    BIORESOURCE TECHNOLOGY, 2012, 123 : 566 - 573
  • [50] Modeling membrane fouling in a submerged membrane bioreactor by considering the role of solid, colloidal and soluble components
    Wu, Jun
    He, Chengda
    Zhang, Yaping
    JOURNAL OF MEMBRANE SCIENCE, 2012, 397 : 102 - 111