Volumetric Modulated Arc Therapy Planning for Craniospinal Irradiation With a New O-ring Linac

被引:0
|
作者
Matsumoto, Kenji [1 ]
Monzen, Hajime [2 ]
Kubo, Kazuki [2 ]
Otsuka, Masakazu [1 ]
Nambu, Hidekazu [1 ]
Nishimura, Yasumasa [3 ]
机构
[1] Kindai Univ Hosp, Dept Radiol Serv, Osakasayama, Japan
[2] Kindai Univ, Grad Sch Med Sci, Dept Med Phys, Osaka, Japan
[3] Kindai Univ, Fac Med, Osakasayama, Japan
关键词
auto-feathering; halcyon; rapidarc; csi; supine craniospinal irradiation; RADIOTHERAPY; IMRT;
D O I
10.7759/cureus.36493
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aims to determine the feasibility of using a new O-ring linear accelerator (Halcyon, Varian Medical Systems, CA, USA) to perform treatment planning using volumetric modulated arc therapy (VMAT) for craniospinal irradiation (CSI).A 20-year-old male patient with leukemia was selected. The planning target volume (PTV) was contoured to include the entire contents of the brain and spinal canal. The PTV margin was 10 mm applied to the clinical target volume (CTV). VMAT (RapidArc, Varian Medical Systems, CA, USA) planning was performed using four isocenter with five arcs, two full rotation arcs to cover the brain and upper part of the spinal cord, and one full rotation arc for the lower part of the spinal cord. The plan was created using the auto-feathering photon optimizer calculation of the planning system. The conformity index (CI) and heterogeneity index (HI) as well as dose-volume histograms of organs at risk (OAR) were evaluated. The patient position of +/- 3.0 mm in the craniocaudal direction was moved in to simulate the effect of treatment inaccuracy. The total treatment time was also measured.The CI and HI were 1.09 and 8.44, respectively. The mean dose (PTV) was 105.5%, and the mean dose (OARs) was lower than the planning dose constraints. Simulations with a patient position shift of +/- 3.0 mm resulted in an error of less than +/- 10.0% of the planned dose to the spinal cord. The total treatment time was within 15 minutes.VMAT planning for CSI with Halcyon achieved high conformality, uniform dose distribution, low dose to the surrounding normal tissues, and reduced treatment time.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A robust planning approach for respiratory motion in accelerated partial breast irradiation using volumetric modulated arc therapy
    Yamauchi, Ryohei
    Tomita, Fumihiro
    Ishikura, Satoshi
    JOURNAL OF RADIATION RESEARCH, 2025, : 185 - 195
  • [32] Automatic planning of the lower extremities for total marrow irradiation using volumetric modulated arc therapy
    Lambri, Nicola
    Dei, Damiano
    Hernandez, Victor
    Castiglioni, Isabella
    Clerici, Elena
    Crespi, Leonardo
    De Philippis, Chiara
    Loiacono, Daniele
    Navarria, Pierina
    Reggiori, Giacomo
    Rusconi, Roberto
    Tomatis, Stefano
    Bramanti, Stefania
    Scorsetti, Marta
    Mancosu, Pietro
    STRAHLENTHERAPIE UND ONKOLOGIE, 2023, 199 (04) : 412 - 419
  • [33] Automatic planning of the lower extremities for total marrow irradiation using volumetric modulated arc therapy
    Nicola Lambri
    Damiano Dei
    Victor Hernandez
    Isabella Castiglioni
    Elena Clerici
    Leonardo Crespi
    Chiara De Philippis
    Daniele Loiacono
    Pierina Navarria
    Giacomo Reggiori
    Roberto Rusconi
    Stefano Tomatis
    Stefania Bramanti
    Marta Scorsetti
    Pietro Mancosu
    Strahlentherapie und Onkologie, 2023, 199 : 412 - 419
  • [34] The dosimetric impact of trade-off optimization in high-quality Craniospinal Irradiation plans based on volumetric modulated arc therapy technique
    Biswal, Subhra S.
    Sarkar, Biplab
    Goyal, Monika
    Ganesh, Tharmarnadar
    MEDICAL DOSIMETRY, 2025, 50 (01) : 36 - 42
  • [35] A method for optimizing LINAC treatment geometry for volumetric modulated arc therapy of multiple brain metastases
    Kang, Jun
    Ford, Eric C.
    Smith, Koren
    Wong, John
    McNutt, Todd R.
    MEDICAL PHYSICS, 2010, 37 (08) : 4146 - 4154
  • [36] Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators
    Sun, Tao
    Lin, Xiutong
    Li, Kuo
    Qiu, Qingtao
    Duan, Jinghao
    Zhang, Guifang
    Yin, Yong
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [37] Volumetric modulated arc therapy for total body irradiation: A feasibility study using Pinnacle3 treatment planning system and Elekta Agility linac
    Symons, Kirsty
    Morrison, Colm
    Parry, Jason
    Woodings, Simon
    Zissiadis, Yvonne
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 103 - 110
  • [38] Single Arc Volumetric Modulated Arc Therapy of head and neck cancer
    Bertelsen, Anders
    Hansen, Christian R.
    Johansen, Jorgen
    Brink, Carsten
    RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) : 142 - 148
  • [39] Volumetric modulated arc therapy planning for distal oesophageal malignancies
    Hawkins, M. A.
    Bedford, J. L.
    Warrington, A. P.
    Tait, D. M.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1009) : 44 - 52
  • [40] Oral contrast agents lead to underestimation of dose calculation in volumetric-modulated arc therapy planning for pelvic irradiation
    Jing, Hao
    Tian, Yuan
    Tang, Yu
    Wang, Shu-Lian
    Jin, Jing
    Song, Yong-Wen
    Liu, Yue-Ping
    Fang, Hui
    Chen, Bo
    Qi, Shu-Nan
    Tang, Yuan
    Lu, Ning-Ning
    Yang, Yong
    Li, Ning
    Li, Ye-Xiong
    CHINESE MEDICAL JOURNAL, 2020, 133 (17) : 2061 - 2070