Volumetric Modulated Arc Therapy Planning for Craniospinal Irradiation With a New O-ring Linac

被引:0
|
作者
Matsumoto, Kenji [1 ]
Monzen, Hajime [2 ]
Kubo, Kazuki [2 ]
Otsuka, Masakazu [1 ]
Nambu, Hidekazu [1 ]
Nishimura, Yasumasa [3 ]
机构
[1] Kindai Univ Hosp, Dept Radiol Serv, Osakasayama, Japan
[2] Kindai Univ, Grad Sch Med Sci, Dept Med Phys, Osaka, Japan
[3] Kindai Univ, Fac Med, Osakasayama, Japan
关键词
auto-feathering; halcyon; rapidarc; csi; supine craniospinal irradiation; RADIOTHERAPY; IMRT;
D O I
10.7759/cureus.36493
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aims to determine the feasibility of using a new O-ring linear accelerator (Halcyon, Varian Medical Systems, CA, USA) to perform treatment planning using volumetric modulated arc therapy (VMAT) for craniospinal irradiation (CSI).A 20-year-old male patient with leukemia was selected. The planning target volume (PTV) was contoured to include the entire contents of the brain and spinal canal. The PTV margin was 10 mm applied to the clinical target volume (CTV). VMAT (RapidArc, Varian Medical Systems, CA, USA) planning was performed using four isocenter with five arcs, two full rotation arcs to cover the brain and upper part of the spinal cord, and one full rotation arc for the lower part of the spinal cord. The plan was created using the auto-feathering photon optimizer calculation of the planning system. The conformity index (CI) and heterogeneity index (HI) as well as dose-volume histograms of organs at risk (OAR) were evaluated. The patient position of +/- 3.0 mm in the craniocaudal direction was moved in to simulate the effect of treatment inaccuracy. The total treatment time was also measured.The CI and HI were 1.09 and 8.44, respectively. The mean dose (PTV) was 105.5%, and the mean dose (OARs) was lower than the planning dose constraints. Simulations with a patient position shift of +/- 3.0 mm resulted in an error of less than +/- 10.0% of the planned dose to the spinal cord. The total treatment time was within 15 minutes.VMAT planning for CSI with Halcyon achieved high conformality, uniform dose distribution, low dose to the surrounding normal tissues, and reduced treatment time.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Optimization approaches to volumetric modulated arc therapy planning
    Unkelbach, Jan
    Bortfeld, Thomas
    Craft, David
    Alber, Markus
    Bangert, Mark
    Bokrantz, Rasmus
    Chen, Danny
    Li, Ruijiang
    Xing, Lei
    Men, Chunhua
    Nill, Simeon
    Papp, David
    Romeijn, Edwin
    Salari, Ehsan
    MEDICAL PHYSICS, 2015, 42 (03) : 1367 - 1377
  • [22] A comprehensive formulation for volumetric modulated arc therapy planning
    Nguyen, Dan
    Lyu, Qihui
    Ruan, Dan
    O'Connor, Daniel
    Low, Daniel A.
    Sheng, Ke
    MEDICAL PHYSICS, 2016, 43 (07) : 4263 - 4272
  • [23] PRECLINICAL ASSESSMENT OF VOLUMETRIC MODULATED ARC THERAPY FOR TOTAL MARROW IRRADIATION
    Fogliata, Antonella
    Cozzi, Luca
    Clivio, Alessandro
    Ibatici, Adalberto
    Mancosu, Pietro
    Navarria, Piera
    Nicolini, Giorgia
    Santoro, Armando
    Vanetti, Eugenio
    Scorsetti, Marta
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (02): : 628 - 636
  • [24] Knowledge-based volumetric modulated arc therapy treatment planning for breast cancer
    Apaza Blanco, Oscar
    Almada, Maria
    Garcia Andino, Albin
    Zunino, Silvia
    Venencia, Daniel
    JOURNAL OF MEDICAL PHYSICS, 2021, 46 (04) : 334 - 340
  • [25] Comparative Planning Analysis and Integral Dose of Volumetric Modulated Arc Therapy, Helical Tomotherapy, and Three-dimensional Conformal Craniospinal Irradiation for Pediatric Medulloblastoma
    Patel, Samir
    Drodge, Suzanne
    Jacques, Amanda
    Warkentin, Heather
    Powell, Kent
    Chafe, Susan
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2015, 46 (02) : 134 - 140
  • [26] VOLUMETRIC MODULATED ARC THERAPY (VMAT) TREATMENT PLANNING FOR SUPERFICIAL TUMORS
    Zacarias, Albert S.
    Brown, Mellonie F.
    Mills, Michael D.
    MEDICAL DOSIMETRY, 2010, 35 (03) : 226 - 229
  • [27] A fast optimization approach for treatment planning of volumetric modulated arc therapy
    Yan, Hui
    Dai, Jian-Rong
    Li, Ye-Xiong
    RADIATION ONCOLOGY, 2018, 13
  • [28] Volumetric modulated arc therapy versus intensity-modulated proton therapy in the postoperative irradiation of thymoma
    Franceschini, Davide
    Cozzi, Luca
    Loi, Mauro
    Franzese, Ciro
    Reggiori, Giacomo
    Mancosu, Pietro
    Clivio, Alessandro
    Fogliata, Antonella
    Scorsetti, Marta
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2020, 146 (09) : 2267 - 2276
  • [29] A generalized inverse planning tool for volumetric-modulated arc therapy
    Cao, Daliang
    Afghan, Muhammad K. N.
    Ye, Jinsong
    Chen, Fan
    Shepard, David M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (21) : 6725 - 6738
  • [30] Fully automated treatment planning of spinal metastases - A comparison to manual planning of Volumetric Modulated Arc Therapy for conventionally fractionated irradiation
    Buergy, Daniel
    Sharfo, Abdul Wahab M.
    Heijmen, Ben J. M.
    Voet, Peter W. J.
    Breedveld, Sebastiaan
    Wenz, Frederik
    Lohr, Frank
    Stieler, Florian
    RADIATION ONCOLOGY, 2017, 12