Introduction: The objective was to compare the stability of hydroxyapatite-coated (HA) temporary anchorage devices (TADs) with uncoated TADs. Methods: Maxillary arches of 92 patients with Class II Division 1 maloc-clusion requiring premolar extractions were randomly distributed to receive both types of Ti-6Al-4V alloy TADs by a single operator. TADs were replicas of each other except for the HA precipitation surface coating of the threaded part. TADs were placed between the roots of the first molar and the second premolar and were immediately loaded by a 300 g of force nickel-titanium spring for retraction of the anterior segment. The main outcome was the loosening of the TAD. Results: TADs of each type were placed in 92 patients. The patients were recalled monthly for 18 months; 10 TADs failed in the HA-coated group (11%), whereas 12 TADs (13%) failed in the uncoated group, with a statistically insignificant difference between the survivability of the TADs in the 2 groups (P = 0.67, log-rank). The Kaplan-Meier curve showed better survivability of the HA-coated TADs between the second and fifth months. The TADs placed on the left side (19.6%) failed significantly more than on the right side (4.3%) (P = 0.002) when placed by a right-handed operator in right-handed patients. Conclusion: The premise that the HA-coated TADs will have a lower failure rate seems incorrect.
引用
收藏
页码:520 / 525
页数:6
相关论文
共 34 条
  • [1] Miniscrews failure rate in orthodontics: systematic review and meta-analysis
    Alharbi, Fahad
    Almuzian, Mohammed
    Bearn, David
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 2018, 40 (05) : 519 - 530
  • [2] Success rates and factors associated with failure of temporary anchorage devices: A prospective clinical trial
    Aly, Shehab A.
    Alyan, Doha
    Fayed, Mona S.
    Alhammadi, Maged S.
    Mostafa, Yehya A.
    [J]. JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2018, 9 (03) : e12331
  • [3] Cheng SJ, 2004, INT J ORAL MAX IMPL, V19, P100
  • [4] Sustained plasmid DNA release from dissolving mineral coatings
    Choi, Siyoung
    Murphy, William L.
    [J]. ACTA BIOMATERIALIA, 2010, 6 (09) : 3426 - 3435
  • [5] Determinants for success rates of temporary anchorage devices in orthodontics: a meta-analysis (n > 50)
    Dalessandri, Domenico
    Salgarello, Stefano
    Dalessandri, Michela
    Lazzaroni, Elena
    Piancino, Mariagrazia
    Paganelli, Corrado
    Maiorana, Carlo
    Santoro, Franco
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 2014, 36 (03) : 303 - 313
  • [6] Comparison of in-vivo failure of single-thread and dual-thread temporary anchorage devices over 18 months: A split-mouth randomized controlled trial
    Durrani, Owais Khalid
    Shaheed, Sohrab
    Khan, Arsalan
    Bashir, Ulfat
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2017, 152 (04) : 451 - 457
  • [7] Influence of Laser-Lok Surface on Immediate Functional Loading of Implants in Single-Tooth Replacement: A 2-Year Prospective Clinical Study
    Farronato, Davide
    Mangano, Francesco
    Briguglio, Francesco
    Iorio-Siciliano, Vincenzo
    Riccitiello, Francesco
    Guarnieri, Renzo
    [J]. INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2014, 34 (01) : 79 - 90
  • [8] Formation and adhesion of biomimetic hydroxyapatite deposited on titanium substrates
    Forsgren, Johan
    Svahn, Fredrik
    Jarmar, Tobias
    Engqvist, Hakan
    [J]. ACTA BIOMATERIALIA, 2007, 3 (06) : 980 - 984
  • [9] Guarnieri R, 2015, INT J PERIODONT REST, V35, P865, DOI 10.11607/prd.2273
  • [10] The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study
    Hansson, S
    Werke, M
    [J]. JOURNAL OF BIOMECHANICS, 2003, 36 (09) : 1247 - 1258