4D-Printed Elution-Peak-Guided Dual-Responsive Monolithic Packing for the Solid-Phase Extraction of Metal Ions

被引:4
作者
Tsai, Wen-Hsiu [1 ]
Su, Cheng-Kuan [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
关键词
PLASMA-MASS-SPECTROMETRY; ICP-MS DETERMINATION; TRACE-ELEMENTS; SAMPLE PREPARATION; ANALYTICAL-CHEMISTRY; ATOMIC SPECTROSCOPY; 3D; PRECONCENTRATION; SEAWATER; TEMPERATURE;
D O I
10.1021/acs.analchem.3c04961
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Four-dimensional printing (4DP) technologies are revolutionizing the fabrication of stimuli-responsive devices. To advance the analytical performance of conventional solid-phase extraction (SPE) devices using 4DP technology, in this study, we employed N-isopropylacrylamide (NIPAM)-incorporated photocurable resins and digital light processing three-dimensional printing to fabricate an SPE column with a [H+]/temperature dual-responsive monolithic packing stacked as interlacing cuboids to extract Mn, Co, Ni, Cu, Zn, Cd, and Pb ions. When these metal ions were eluted using 0.5% HNO3 solution as the eluent at a temperature below the lower critical solution temperature of polyNIPAM, the monolithic packing swelled owing to its hydrophilic/hydrophobic transition and electrostatic repulsion among the protonated units of polyNIPAM. These effects resulted in smaller interstitial volumes among these interlacing cuboids and improvements in the elution peak profiles of the metal ions, which, in turn, demonstrated the reduced method detection limits (MDLs; range, 0.2-7.2 ng L-1) during analysis using inductively coupled plasma mass spectrometry. We studied the effects of optimizing the elution peak profiles of the metal ions on the analytical performance of this method and validated its reliability and applicability by analyzing the metal ions in reference materials (CASS-4, SLRS-5, 1643f, and Seronorm Trace Elements Urine L-2) and performing spike analyses of seawater, groundwater, river water, and human urine samples. Our results suggest that this 4D-printed elution-peak-guided dual-responsive monolithic packing enables lower MDLs when packed in an SPE column to facilitate the analyses of the metal ions in complex real samples.
引用
收藏
页码:4469 / 4478
页数:10
相关论文
共 75 条
  • [71] Tuning the fabrication of knotted reactors via 3D printing techniques and materials
    Wang, Man -Wen
    Su, Cheng-Kuan
    [J]. ANALYTICA CHIMICA ACTA, 2023, 1263
  • [72] 4D-Printed Temperature-Controlled Flow-Actuated Solid-Phase Extraction Devices
    Wu, Chun-Yi
    Chen, Jyun-Ran
    Su, Cheng-Kuan
    [J]. ANALYTICAL CHEMISTRY, 2021, 93 (33) : 11497 - 11505
  • [73] Four-dimensional printing of a novel acrylate-based shape memory polymer using digital light processing
    Wu, Hongzhi
    Chen, Peng
    Yan, Chunze
    Cai, Chao
    Shi, Yusheng
    [J]. MATERIALS & DESIGN, 2019, 171
  • [74] Speciation of dissolved iron(III) and iron(II) in water by on-line coupling of flow injection separation and preconcentration with inductively coupled plasma mass spectrometry
    Yan, XP
    Hendry, NJ
    Kerrich, R
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (08) : 1879 - 1884
  • [75] Improvement in Detection Limit for Lateral Flow Assay of Biomacromolecules by Test-Zone Pre-enrichment
    Zhang, Yi
    Liu, Xiao
    Wang, Lingling
    Yang, Hanjie
    Zhang, Xiaoxiao
    Zhu, Chenglong
    Wang, Wenlong
    Yan, Lijing
    Li, Bowei
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01) : 9604