4D-Printed Elution-Peak-Guided Dual-Responsive Monolithic Packing for the Solid-Phase Extraction of Metal Ions

被引:4
作者
Tsai, Wen-Hsiu [1 ]
Su, Cheng-Kuan [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
关键词
PLASMA-MASS-SPECTROMETRY; ICP-MS DETERMINATION; TRACE-ELEMENTS; SAMPLE PREPARATION; ANALYTICAL-CHEMISTRY; ATOMIC SPECTROSCOPY; 3D; PRECONCENTRATION; SEAWATER; TEMPERATURE;
D O I
10.1021/acs.analchem.3c04961
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Four-dimensional printing (4DP) technologies are revolutionizing the fabrication of stimuli-responsive devices. To advance the analytical performance of conventional solid-phase extraction (SPE) devices using 4DP technology, in this study, we employed N-isopropylacrylamide (NIPAM)-incorporated photocurable resins and digital light processing three-dimensional printing to fabricate an SPE column with a [H+]/temperature dual-responsive monolithic packing stacked as interlacing cuboids to extract Mn, Co, Ni, Cu, Zn, Cd, and Pb ions. When these metal ions were eluted using 0.5% HNO3 solution as the eluent at a temperature below the lower critical solution temperature of polyNIPAM, the monolithic packing swelled owing to its hydrophilic/hydrophobic transition and electrostatic repulsion among the protonated units of polyNIPAM. These effects resulted in smaller interstitial volumes among these interlacing cuboids and improvements in the elution peak profiles of the metal ions, which, in turn, demonstrated the reduced method detection limits (MDLs; range, 0.2-7.2 ng L-1) during analysis using inductively coupled plasma mass spectrometry. We studied the effects of optimizing the elution peak profiles of the metal ions on the analytical performance of this method and validated its reliability and applicability by analyzing the metal ions in reference materials (CASS-4, SLRS-5, 1643f, and Seronorm Trace Elements Urine L-2) and performing spike analyses of seawater, groundwater, river water, and human urine samples. Our results suggest that this 4D-printed elution-peak-guided dual-responsive monolithic packing enables lower MDLs when packed in an SPE column to facilitate the analyses of the metal ions in complex real samples.
引用
收藏
页码:4469 / 4478
页数:10
相关论文
共 75 条
  • [1] Matrix effects in inductively coupled plasma mass spectrometry: A review
    Agatemor, Christian
    Beauchemin, Diane
    [J]. ANALYTICA CHIMICA ACTA, 2011, 706 (01) : 66 - 83
  • [2] ICP-MS and trace element analysis as tools for better understanding medical conditions
    Amais, Renata S.
    Donati, George L.
    Zezzi Arruda, Marco A.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 133
  • [3] Light-Driven Polarity Switching of the Chromatographic Stationary Phase with Photoreversibility
    An, Zhengjiu
    Zhang, Jie-Min
    Lv, Ming-Yu
    Li, Xin-Qi
    Wu, Lixin
    Shang, Hai-Bo
    Li, Donghao
    [J]. ANALYTICAL CHEMISTRY, 2021, 93 (51) : 17051 - 17059
  • [4] On-line solid phase extraction system using PTFE packed column for the flame atomic absorption spectrometric determination of copper in water samples
    Anthemidis, AN
    Zachariadis, GA
    Stratis, JA
    [J]. TALANTA, 2001, 54 (05) : 935 - 942
  • [5] 3D Printing: An Alternative Microfabrication Approach with Unprecedented Opportunities in Design
    Balakrishnan, Hari Kalathil
    Badar, Faizan
    Doeven, Egan H.
    Novak, James, I
    Merenda, Andrea
    Dumee, Ludovic F.
    Loy, Jennifer
    Guijt, Rosanne M.
    [J]. ANALYTICAL CHEMISTRY, 2021, 93 (01) : 350 - 366
  • [6] Analysis of Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb in seawater using the Nobias-chelate PA1 resin and magnetic sector inductively coupled plasma mass spectrometry (ICP-MS)
    Biller, Dondra V.
    Bruland, Kenneth W.
    [J]. MARINE CHEMISTRY, 2012, 130 : 12 - 20
  • [7] Past, Present, and Future of Solid Phase Extraction: A Review
    Buszewski, Boguslaw
    Szultka, Malgorzata
    [J]. CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2012, 42 (03) : 198 - 213
  • [8] 3D printed device for the automated preconcentration and determination of chromium (VI)
    Calderilla, Carlos
    Maya, Fernando
    Cerda, Victor
    Leal, Luz O.
    [J]. TALANTA, 2018, 184 : 15 - 22
  • [9] Solid phase extraction of trace elements
    Camel, V
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (07) : 1177 - 1233
  • [10] TiO2 nanoparticle-Coated 3D-Printed porous monoliths enabling highly sensitive speciation of inorganic Cr, As, and Se
    Chen, Jyun-Ran
    Tsai, Wen-Hsiu
    Su, Cheng-Kuan
    [J]. ANALYTICA CHIMICA ACTA, 2023, 1271